| AMBW-49418 | Summary: An error "Connection to the derby db failed" is thrown when the old workspace is opened i.e. the workspace created prior to ActiveMatrix BusinessWorks 6.10.0 containing the SmartMapper project that uses the Remoted DB feature with the provided DD driver URL. Workaround: To proceed further, in the error popup, click OK and in the Preference tab, change the DB details to the native driver URL. Then restart TIBCO Business Studio for BusinessWorks. |
| AMBW-49366 | Summary: The generated mock output or gold input file gets overwritten when two activities have the same name in the application. Workaround: None |
| AMBW-48925 | Summary: When a module property is directly mapped to an activity input without creating a process property, the mapping line is not seen. Workaround: None |
| AMBW-48217 | Summary: When the shared resource takes time to connect to the Database or Server, intermittently an error "Init module failed for module" is thrown at runtime even though the values provided in the shared resource are correct. Workaround: Introduce a sleep or re-run the application manually using startcomp OSGI commands. |
| AMBW-47025 | Summary: After creating the Maven test file, if the user renames the TIBCO ActiveMatrix BusinessWorks™ Process name, the change is not reflected. The user cannot test run the same. Workaround: Re-create the test file after renaming the process. |
| AMBW-46231 | Summary: When two properties from two different modules having a common name are promoted, only one property gets promoted and seen under the application. Workaround: Keep each property name unique before promoting in a batch. |
| BWCE-5076 | Summary: For RHEL 9.x, the check box selection for any BusinessWorks activity is not visible. Workaround: None |
| AMBW-46056 | Summary: The OSGi commands to start and stop the application do not work. Workaround: Use TEA, Admin CLI, or REST API to start and stop the application. |
| AMBW-45408 | Summary: The Ant task failure error occurs when you uninstall ActiveMatrix BusinessWorks 6.8.0 hotfixes, 6.8.0, and 6.7.0 from the TIBCO_HOME containing the version 6.7.0.
Workaround: Ignore the errors and proceed further with uninstallation. |
| AMBW-45183 | Summary: A non-readable POM file error is thrown upon importing CXF project from Maven repository. Workaround: None. It does not affect the functionality. |
| AMBW-45146 | Summary: The FluentD container fails to insert the activity (input/output) data if the data size is greater than 4000 characters for the Oracle database. Workaround: Set the MAX_STRING_SIZE = EXTENDED for the Oracle database, which increases the byte size capacity from 4000(default) to 32767. Note that this change is at the server level and is irreversible. |
| AMBW-45015 | Summary: An activity having a large input data is not shown in the job details on the Execution History tab for MySQL. Workaround: None |
| AMBW-44769 | Summary: On some Linux machines, you cannot launch TIBCO Business Studio for BusinessWorks. Workaround: You must ensure that you have GTK 3.2 installed on your machine and then re-launch TIBCO Business Studio for BusinessWorks. |
| AMBW-44643 | Summary: The Transform XML activity's output is not visible in Job Data debugger output tab.
Workaround: This issue occurs only on Windows operating system. So a mouse click and mouse hover on the Job Data section during debugging the application on the Transform XML activity displays the output. |
| AMBW-44437 | Summary: Two .application folders are created when a new application is created in a new workspace.Workaround: On launching TIBCO Business Studio for BusinessWorks wait for 5-10 seconds to ensure that it loads completely and then create a new application. If there are two |
| AMBW-43862 | Summary: EMF Validation does not work for imported existing projects by using Module Property to Keystore URL. Workaround: Reassigning the same module property resolves the validation error. |
| AMBW-43860 | Summary: Consuming a TIBCO Flogo service with parameters having Object data type in Input and Output schema from ActiveMatrix BusinessWorks client is not supported.
Workaround: None |
| AMBW-43779 | Summary: Unit testing does not start when a connection is not successful for the HTTP Receiver being mocked.
Workaround: None |
| AMBW-43743 | Summary: Unit testing framework does not support Java palette activities.
Workaround: None. |
| AMBW-43118 | Summary: For Open API Specification 3.0 service, the array of Form Parameters is sent as comma-separated values from Swagger UI which causes the request to fail with the 500 internal server error in TCI.
Workaround: Use Runtime swagger file to create the service. |
| AMBW-42385 | Summary: You can't launch TIBCO Business Studio for BusinessWorks after adding it into Dock in MAC OS.
Workaround: None. |
| AMBW-42174 | Summary: Customization of template for an unencrypted project template fails. Workaround: Import the template directly in TIBCO Business Studio for BusinessWorks and rename it as per your requirement. |
| AMBW-42046 | Summary: Encryption Setting Window shows no editable fields when opened by clicking on the Lock Icon if
TIBCO Business Studio™ for BusinessWorks™ is not in full-screen mode.
Workaround: Open Encryption Settings when TIBCO Business Studio for BusinessWorks is in full-screen mode or enter into full-screen mode for Encryption setting if it is opened in a minimized view. |
| AMBW-41991 | Summary: Eclipse command line options such as
-clean does not work with TIBCO_HOME/studio/4.0/eclipse/TIBCOBusinessStudio.app/Contents/MacOS/TIBCOBusinessStudio executable on macOS platform.
Workaround: Use the following command: TIBCO_HOME/studio/4.0/eclipse/Eclipse.app/Contents/MacOS/TIBCOBusinessStudio --launcher.ini TIBCO_HOME/studio/4.0/eclipse/TIBCOBusinessStudio.ini -clean or any other eclipse command line option |
| AMBW-41950 | Summary: In bwdesign, if we export
substvar files with the same name twice in the same location, it does not overwrite the
substvar file.
Workaround: Delete the previous substvar file and export substvar again. |
| AMBW-41948 | Summary: Many to one mapping is not supported for Smart Mapper.
Workaround: None |
| AMBW-41846 | Summary: Any operation on the module or application properties that leads to a change in their order results in a faulty difference generation. So, such operations are not supported in
TIBCO ActiveMatrix BusinessWorks™ 6.7.0.
Workaround: None. |
| AMBW-41832 | Summary: The lock icon on the encrypted profile in the difference viewer perspective is shown based on whether the workspace copy of the profile is encrypted or not. Currently, if the workspace copy of the profile is encrypted, then in the difference viewer perspective, the lock icon is shown even on the un-encrypted revisions of that profile.
Workaround: None. |
| AMBW-41827 | Summary: The properties and profile are not showing in the application property editor on opening the editor for the first time in a new workspace.
Workaround: Close and reopen the editor, it shows all the details. |
| AMBW-41779 | Summary: If a
keystore file location or name is changed then on refresh blank property value is shown and on running the application, the
File Not Found Exception is thrown.
Workaround: Restore file with a valid name at a specified location on disk and do project clean. |
| AMBW-41716 | Summary: Any changes in the module or application properties inside groups are not supported in
ActiveMatrix BusinessWorks 6.7.0 and the corresponding difference generation is faulty in such cases.
Workaround: None. |
| AMBW-41715 | Summary: The difference viewer calculates the difference and highlights the properties, but does not highlight any corresponding fields of the properties.
Workaround: Switch to the text difference mode and see the difference in the non-UI fields. |
| AMBW-41499 | Summary: In the substitution variables file, only five types of module properties are saved: String, Integer, Long, Boolean, and Password.
When a module property is assigned a type other than the above-mentioned types then that type is saved as a String in the substvar file in the Diff Viewer window. Workaround: None. |
| AMBW-41474 | Summary: If there are any changes in the Description field of a module or application property, it is not highlighted in the difference viewer.
Workaround: None. |
| AMBW-41417 |
Summary: Multiple coercion does not work upon trying to toggle the faulty process. Workaround: The QName conflict here refers to having two schemas defining two elements with exact same name and same namespace, but the element contents differ. This causes design-time problems without warning when you use both elements in the same process. |
| AMBW-41307 | Summary: Application property editor does not display value in case of removing encryption setting using the
Clear All button and exporting profile.
Workaround: Close the application properties editor and open it again. |
| AMBW-41277 | Summary: When you try to install a missing plugin using the
Quick Fix option and you select or unselect a plugin version from the list of provided versions; the following message is displayed:
Cannot complete the install because of a conflicting dependency.
However, you can still install the plugin successfully. Workaround: None. |
| AMBW-41271 | Summary: The application property editor doesn't get refreshed intermediately on encrypting profiles.
Workaround: None. |
| AMBW-41252 | Summary: The New Name field in the Rename Projects section on the Create Project From Template window is not enabled on a single click.
Workaround: First click on the old name of the module or the application after which the field is enabled. . |
| AMBW-41155 | Summary: The Password field is shown as changed while doing a Shared Resource diff, even if the password are the same.
Workaround: None. |
| AMBW-41238 | Summary: Confirmation message is displayed with any operation on encrypted profiles.
Workaround: Click Yes. |
| AMBW-41035 | Summary: The
Authentication field is shown while doing a diff when the
Confidentiality field is set for HTTP Connector shared resource.
Workaround: None. |
| AMBW-40811 | Summary: Default icon shown instead of Custom icon for the Call Process and Java Invoke activities within external shared module.
Workaround: Manually browse the Custom icon field value and add respective icon to activity on importing external shared module. |
| AMBW-40464 | Summary:ActiveMatrix BusinessWorks applications fail at run time in TIBCO Cloud Integration if they consume a Flogo endpoint that has Post/Put Operations.
Workaround: None. |
| AMBW-40010 | Summary:null pointer exception is thrown at run time on
ActiveMatrix BusinessWorks Mesh client when the organization name contains a space character.
Workaround: When importing the ASR descriptor json file to create a Mesh client, there is a second wizard page for customizing json file location (Change swagger name). In that wizard page, remove the space from the folder name. |
| AMBW-39899 | Summary: The
null pointer exception reported on clicking Binding Section in Components after the Refactoring operation.
Workaround: Post refactoring, close the Module Descriptor section and reopen it. No popup is displayed. |
| AMBW-39887 | Summary:ActiveMatrix BusinessWorks Mesh Client applications fail at runtime in TIBCO Cloud Integration if they consume a Flogo Mesh Service that has Post or Put Operations.
Workaround: None. |
| AMBW-39837 | Summary: The
collectappnodedata command is not working on the AIX platform.
Workaround: None. |
| AMBW-39804 | Summary: SVN compare with revision option doesn't work for any revision other than the base revision.
Workaround: None. |
| AMBW-38593 | Summary: Condition fails to evaluate completely when you try to equate a boolean value to a string.
For example:-If an expression is
Workaround: Simply update "false" to false() or 0 and run the project. It runs as expected (or vice-versa if its equated to "true" value) |
| AMBW-38580 | Summary:Transition configuration error for specific customer projects.
Workaround: When a project has the Invalid expression value: [: not a Boolean] error, complete the transition by equating it to either "true" ("1") or "false" ("0") and run the project. |
| AMBW-37714 | Summary:Local Transaction group option is not present in the drop-down list present for the Group Type field for a group.
Workaround: User should ungroup the existing group and create a new group. |
| AMBW-37594 | Summary: Breakpoints are not working when execution flow goes from one process to another.
Workaround: Select an activity where debugging with the breakpoint is halted. It enables the Resume button. Click the button to resume debugging. |
| AMBW-36990 | Summary: When you delete a module shared variables or job shared variables from the
Unused Resources view, then the editor for module shared variables or job shared variables does not get refreshed automatically.
Workaround: Close the module shared variables or job shared variables editor and open it again. |
| AMBW-34416 | Summary: Failed to connect to AppNode using SSH client
Workaround: Use HTTP client. Preferred way is using curl. |
| AMBW-34404 | Summary: Incorrect trace is generated for the invoke process with default jaeger properties.
Workaround: Set
|
| AMBW-34396 | Summary: Clicking
Help Contents shows
HTTP ERROR: 500 error.
Workaround: None |
| AMBW-34343 | Summary: An application fails to start in
TIBCO Business Studio™ for BusinessWorks™ when you install the latest EMS driver.
Workaround: Restart TIBCO Business Studio for BusinessWorks. |
| AMBW-32761 | Summary: The user will not be able to create the references for the custom operations such as Merge, Update, Trace using the drag and drop swagger file approach.
Workaround: Users can create the references for the custom operations using the REST Reference wizard. |
| AMBW-28941 | Summary: Ungrouping nested groups created inside a
Catch block of a group may not ungroup as expected.
Workaround: None |
| AMBW-28663 | Summary: The
tibco.bw.sample.policy.samlcredentialmapping.SoapHttpBinding sample fails intermittently with the error:
com.tibco.governance.agent.action.ActionException.
Workaround: None |
| AMBW-28378 | Summary: When a process property is renamed , the change is not reflected in the activity and an error is displayed.
Workaround: None |
| AMBW-28319 | Summary: WSDL interface fails to resolve correctly if multiple WSDLs share the same target namespace and the SOAP invoke is created with an external binding reference.
Workaround: Instead of an external reference binding, use binding reference. |
| AMBW-28264 | Summary: When groups with the On Catch, Catch All and the OnEvent faults are created inside a constructor or a proxy operation, the activities inside them are lost after ungrouping.
Workaround: None |
| AMBW-27253 | Summary: The
Identity Provider field in the
WSS Consumer policy resource does not support module properties.
Workaround: None |
| AMBW-25219 | Summary: Multiple
End activities use the same variable in
TIBCO ActiveMatrix BusinessWorks™.
Workaround: None |
| AMBW-25073 | Summary: The option to test connections, for example JMS or sFTP, in a shared resource that has a profile is not supported in
TIBCO Business Studio for BusinessWorks.
Workaround: Specify the server configuration details as literal value or module properties. |
| AMBW-24508 | Summary:TIBCO-THOR-FRWK-CMN-500001:Error while renaming bundle file to final location: - error could be displayed due to low disk space.
Workaround: None |
| AMBW-19746 | Summary: When you initialize the module shared variable of XSD type with the select value option to point the XML instance, application fails to start at run time.
Workaround: Enforce the default encoding of AppNode JVM to UTF-8 by adding
|
| AMBW-19540 |
Summary: When a project contain abstract and concrete WSDL using same target namespace, a validation error is generated. Workaround: None |
| AMBW-18459 | Summary: The ability to reference from a standalone (external) schema to an inline schema is not supported. If your project contains such a reference, a validation error is generated.
Workaround: Externalize the WSDL-inline schema and change the import statements to reference the newly created (external) schema. |
| AMBW-17562 | Summary: The OSGi configuration properties have been aligned between the debug environment launched from within
TIBCO Business Studio for BusinessWorks and the AppNode that is launched in an installation. However, a difference in behavior of the
osgi.compatibility.bootdelegation property in both the environments has been observed.
Workaround: None |
| AMBW-16256 | Summary: The first attempt to change the data type of an Operator's input or output schema element fails and the change is not committed. Subsequent attempts complete without any failure.
Workaround: To commit the change, you must press the return key after every change. |
| AMBW-14861 | Summary: Unable to enter an XPath expression on a transition using the XPath Builder. This issue is observed on Mac OS only.
Workaround: Enter the XPath expression directly in the Properties tab > Expression field for the transition without using the XPath Builder. |
| AMBW-12490 | Summary: Under certain circumstances, substitution types do not resolve properly in the mapper. The mapper shows errors for them.
Workaround: Try closing and reopening the project. If that does not solve the issue, try closing and reopening Eclipse. If the errors still persist, perform a project clean (that is, go to the Project menu and click Clean...). |
| AMBW-11534 | Summary:TIBCO Business Studio for BusinessWorks crashes occasionally on Windows 2012 R2 platform when switching workspace from
.
Workaround: Retry by switching the workspace. |