com.tibco.wcc.schema.eventViewsRemoved
This topic describes the data passed in the payload for PageBus event, com.tibco.wcc.schema.eventViewsRemoved.
Data in the PageBus event:
topic: The PageBus topic for the event -- see Non-WCC Components Publishing Events. message: schemaId = "com.tibco.wcc.schema.eventViewsRemoved" scope = "public" items = [ { "View": The event view being removed. "Description": Description of the event view. "DescriptionType": "detail" or "summary". These are defined in the appropriate eventDescriptions.xml file. See the Configuring Events chapter in the Workspace Configuration and Customization guide. "FilterId": The ID of the <filter/> element that is used to initially populate the event list when the view is selected. "ViewType": Describes how the view was created: "context" (for contextual) or "templatex" (for views created with the wizard, where x is a number starting at 0 (zero) indicating sequential position of template in eventViewTemplates.xml file). “UserChangedBase”: Indicates if the user changed the filter using the wizard, which becomes the “base” filter in the event list. “UserChangedFilter”: Indicates if the user changed the filter using the Filter function on the event list. “UserChangedSort”: Indicates if the user changed the sort using the Sort function on the event list. “UserChangedColumns”: Indicates if the user changed the columns using the Column Selector on the event list. "EventImage": Image displayed for view in the event view list. "ViewSource": Indicates “User” or “System” view. "SystemView": "true" if system view’ “false” if user view. "systemViewDate": Date and time the sysyem view was created. "systemViewDescription": "true" if user can modify system view description. "systemViewFilter": "true" if user can modify system view filter. "systemViewBaseFilter": "true" if user can modify system view base filter. "systemViewSort": "true" if user can modify system view sort. "systemViewColumns": "true" if user can modify system view columns. "systemViewEventList": "true" if user can modify the events included in the system view "systemViewReplace": Indicates if the system view definition will replace existing view of same name. "systemViewStartDate": Date system view takes effect. "systemViewEndDate": Date system view is no longer in effect. "systemViewOwner": GUID of user that created system view. "systemViewOwnerName": Name of user that created system view. "systemViewRecipientGroups": GUID of groups specified as recipients of the system view. "systemViewRecipientPositions": GUID of positions specified as recipients of the system view. "systemViewRecipientResources": GUID of resources specified as recipients of the system view. "systemViewAuthorGroups": GUID of groups specified as authors of the system view. "systemViewAuthorPositions": GUID of positions specified as authors of the system view. "systemViewAuthorResources": GUID of resources specified as authors of the system view. "systemViewRecipientVersion": The major version number of the organization model in which the recipient resides. "systemViewAuthorVersion": The major version number of the organization model in which the author resides. "Filter": String value used to query the event collector database for events that are to be displayed in the event view. } ] remainingCount = The number of event views remaining after the removal.
Example:
topic: "com.tibco.wcc.order.wccPrototype.wccEventViews.listItemRemoved"
message: schemaId = "com.tibco.wcc.schema.eventViewsRemoved"
scope = "public"
items = [
{
"View": "My Instances Started",
"Description": "Process instances started by me",
"DescriptionType": "summary",
"FilterId": "All",
"ViewType": "template3",
“UserChangedBase”: “true”
“UserChangedFilter”: “false”
“UserChangedSort”: “false”
“UserChangedColumns”: “false”
"EventImage": "JSXAPPS/base/application/images/
ProcessInstances.gif",
"ViewSource": “User”
"SystemView": “true”
"systemViewDate": "Tue Oct 2 09:22:07 PDT 2012",
"systemViewDescription": "true",
"systemViewFilter": "true",
"systemViewBaseFilter": "true",
"systemViewSort": "true",
"systemViewColumns": "true",
"systemViewEventList": "false",
"systemViewReplace": "true",
"systemViewStartDate": "Mon, 8 Oct 2012 07:00:00 UTC",
"systemViewEndDate": "Fri, 30 Nov 2012 08:00:00 UTC",
"systemViewOwner": "5395A979-AC8C-4D08-AD2F-F2790B449560",
"systemViewOwnerName": "Clint Hill",
"systemViewRecipientGroups": "",
"systemViewRecipientPositions": "",
"systemViewRecipientResources":
"07346908-E92E-4C1F-BF79-8EB6069EDECF",
"systemViewAuthorGroups": "",
"systemViewAuthorPositions": "",
"systemViewAuthorResources":
"A19F1BFB-0739-449A-8572-96EB4743E29D",
"systemViewRecipientVersion": "3",
"systemViewAuthorVersion": "3",
"Filter": "messageId='BX_INSTANCE_PROCESS_STARTED'",
"EventFilters": "<filters>\r\n <filter id=\"All\"
query=\"messageId='BX_INSTANCE_PROCESS_STARTED'\"
description=\"Process instance started events\"/>
\r\n </filters>",
}
]
remainingCount = 6
Copyright © 2022. TIBCO Software Inc. All Rights Reserved.