Changing Log Level Settings for Central Logger

To change the log level settings for the Central Logger, follow these steps:

Procedure

  1. Start the Config UI. See Starting GUI.
  2. Move the mouse pointer on the gateway configuration project and select Publish Project Configuration icon.
  3. On the dialog box wizard, set the values for the fields as follows:
    • Type: from the drop-down list, select Update Central Logger Log Level.
    • Gateway URL: Enter the URL of the Core Engine instance where the log level settings are to be applied. For example,

      http://ASGServerMachine:PortName

      where ASGServerMachine is the server machine and PortName is the port number for a running Core Engine instance.

    • Log Level: Enter the level of logging from the drop-down list. For example, Detail Logging ON. See Central Logger Log Level.
  4. Click Submit.
    Note:
    • The Update log level settings for the Core Engine and the Central Logger are applicable only at run time.
    • When the Core Engine is restarted, the original log level settings for the Core Engine and the Central Logger component are picked up from the ASG_CONFIG_HOME/asg.properties and ASG_CONFIG_HOME/asg_cl.properties files respectively.
      • For the Core Engine, the log level setting is defined by the tibco.clientVar.ASG/Logging/MinLogLevel property in the ASG_CONFIG_HOME/asg.properties file.
      • For the Central Logger component, the log level setting is defined by the tibco.clientVar.ASG/Logging/clLogLevel property in the ASG_CONFIG_HOME/asg_cl.properties file.