Advisory and Error Status Codes
This section describes all the status codes that TIBCO BusinessConnect Container Edition - RosettaNet Protocol generates, some of which are forwarded to the private process. In advisory and error messages, the code and its description are found in the statusCode and statusMsg fields, respectively.
See the following table for descriptions to the codes, as well as suggestions for resolutions when meeting a specific code.
statusCode | statusMsg | Role | Category | Resolution |
---|---|---|---|---|
200
|
OK | |||
201-299 | HTTP(S) OK codes | |||
300 - 499 | HTTP(S) error codes | Error | ||
900 | HTTP(S) send of action/signal failed...attempt retry | Error | System | TIBCO BusinessConnect Container Edition - RosettaNet Protocol attempts retry internally. |
901 | HTTP(S) send of action/signal failed...retry count exceeded | Error | System | Contact your trading partner to verify their gateway's stability or any network problems. |
922 | Time out waiting for Response Document from Private Process | Error | System | Check your private process for problems. |
924 | PIP terminated | Error | System | |
925 | Fatal error in incoming Message | Error | System | Contact your trading partner to verify the incoming message as it appears to be corrupted |
926 | Error in incoming message service header | Error | System | Contact your trading partner to verify the incoming message as it appears malformed in the Service Header. |
927 | Error in incoming message service content | Error | System | Contact your trading partner to verify the incoming message as it appears malformed in the Service Content |
928 | Failed to store Non-Repudiation information | Error | System | Contact your DBA to verify stability of the database. |
929 | Retry attempts exceeded, no incoming acknowledgment from trading partner | Error | System | Contact your Trading Partner to verify their gateway's stability or any network problems |
933 | Received Response Document, expecting acknowledgment receipt from trading partner | Error | System | Contact your trading partner to verify their gateway's software as it appears that they have a messaging sequencing issue. |
999 | Unsupported Response Type | Error | System | Contact your trading partner to verify their gateway's software as it appears that this PIP transaction is not configured to perform the nominated response-type. |
1000 - 1999 | Trading partner–defined codes | Error |
Copyright © Cloud Software Group, Inc. All rights reserved.