Error Codes

The exceptions that are thrown by the TIBCO ActiveMatrix BusinessWorks™ Plug-in for EDI are listed with the corresponding descriptions and resolutions.

Error Code and Message Role Category Description Resolution
TIBCO-BW-PALETTE-EDI-501000

The map is required.

errorRole EDI-Plug-in

ERROR_TRANSLATOR

A translation map is required. Specify a map to be used for translation.
TIBCO-BW-PALETTE-EDI-501001

The input data is required.

errorRole EDI-Plug-in

ERROR_TRANSLATOR

Input data for translation is required. Specify input data to be used for translation.
TIBCO-BW-PALETTE-EDI-501002

The operation type is required.

errorRole EDI-Plug-in

ERROR_TRANSLATOR

An operation type is required. Specify an operation type for translation (e.g., EDItoXML, XMLtoFLAT, etc).
TIBCO-BW-PALETTE-EDI-501004

TIBCO-BW-PALETTE-EDI-501004: return code [<return code>], error message : <error message>

errorRole EDI-Plug-in

ERROR_TRANSLATOR

This error points to a TIBCO Foresight® Translator return code.

For example:

TIBCO-BW-PALETTE-EDI-501004:return code [158], error message : Error 44 : Access map failed

Using the return code provided in the message, refer to the Return Codes section of the TIBCO Foresight® Translator Using Translator PDF document.
TIBCO-BW-PALETTE-EDI-501005

BYMEM_MISSINGSTD={0}

errorRole EDI-Plug-in

ERROR_TRANSLATOR

The selected standard is missing. Ensure the standard is in the correct location.
TIBCO-BW-PALETTE-EDI-501006

METHORD_ERROR={0}{1}

errorRole EDI-Plug-in

ERROR_TRANSLATOR

An exception occurred during translation. This is an internal product error. Contact TIBCO Support.
TIBCO-BW-PALETTE-EDI-501007

Callback is checked, but no class selected.

errorRole EDI-Plug-in

ERROR_TRANSLATOR

The Java Callback checkbox is selected, but no class was specified. Specify a Java Callback class name.
TIBCO-BW-PALETTE-EDI-501008

The output directory {0} does not exist.

errorRole EDI-Plug-in

ERROR_TRANSLATOR

Output directory does not exist in the specified location. Ensure output directory appears in the specified location.
TIBCO-BW-PALETTE-EDI-501009

The output directory is required.

errorRole EDI-Plug-in

ERROR_TRANSLATOR

An output directory is required. Specify a valid output directory.
TIBCO-BW-PALETTE-EDI-501009

The input file {0} does not exist.

errorRole EDI-Plug-in

ERROR_TRANSLATOR

Input file does not exist in the specified location. Ensure input file appears in the specified location.
TIBCO-BW-PALETTE-EDI-501010

CallBack selected, but there is no class defined.

errorRole EDI-Plug-in

ERROR_TRANSLATOR

The Java Callback checkbox is selected, but no class is defined. Define a Java Callback class name.
TIBCO-BW-PALETTE-EDI-502000

MESSAGE= return code [<return code>], error message : <error message>

errorRole EDI-Plug-in ERROR_RESPGEN This error points to a ResponseGenerator return code.

For example:

TIBCO-BW-PALETTE-EDI-501004:return code [180], error message : Failed to initialize Response Generator.

Using the return code provided in the message, refer to the Return Codes section of the Response Generator Technical Manual PDF document.
TIBCO-BW-PALETTE-EDI-502001

At least one acknowledgment must be selected.

errorRole EDI-Plug-in ERROR_RESPGEN No acknowledgment types are selected. Select at least one acknowledgment type.
TIBCO-BW-PALETTE-EDI-502002

Output directory parameter must be supplied.

errorRole EDI-Plug-in ERROR_RESPGEN An output directory is required. Specify a valid output directory.
TIBCO-BW-PALETTE-EDI-502003

Invalid output directory {0}.

errorRole EDI-Plug-in ERROR_RESPGEN The specified output directory is invalid. Specify a valid output directory.
TIBCO-BW-PALETTE-EDI-502004

Could not configure 997 and 999 at the same time.

errorRole EDI-Plug-in ERROR_RESPGEN A 997 acknowledgment and a 999 acknowledgment cannot be generated simultaneously. Generate these response documents separately.
TIBCO-BW-PALETTE-EDI-502005

Could not configure Control and X12 ACK at the same time.

errorRole EDI-Plug-in ERROR_RESPGEN A CTRL response and an X12 acknowledgment cannot be generated simultaneously. Generate these response documents separately.
TIBCO-BW-PALETTE-EDI-503000

MESSAGE= return code [<return code>], error message : <error message>

errorRole EDI-Plug-in ERROR_INSTREAM This error points to an Instream® return code.

For example:

TIBCO-BW-PALETTE-EDI-501004:return code [131], error message : $dir.ini or fsdir.ini cannot be found.

Using the return code provided in the message, refer to the Return Codes section of the Instream Validation Technical Manual PDF document.
TIBCO-BW-PALETTE-EDI-503001

Instream callback missing guideline name.

errorRole EDI-Plug-in ERROR_INSTREAM The Callback checkbox is selected, but no guideline was specified. Specify a guideline name.
TIBCO-BW-PALETTE-EDI-503002

Access input file failed, please check operation mode.

errorRole EDI-Plug-in ERROR_INSTREAM There is a mis-match between the operation mode selected (file or memory) and the input file. Select the correct Operation Type.
TIBCO-BW-PALETTE-EDI-503003

Guideline is required.

errorRole EDI-Plug-in ERROR_INSTREAM A validation guideline is required. Specify a guideline to be used for validation.
TIBCO-BW-PALETTE-EDI-503004

999997=Could not configure 997 and 999 at the same time.

errorRole EDI-Plug-in ERROR_INSTREAM A 997 acknowledgment and a 999 acknowledgment cannot be configured simultaneously. Configure these response documents separately.
TIBCO-BW-PALETTE-EDI-503005

Could not configure Control and X12 ACK at the same time.

errorRole EDI-Plug-in ERROR_INSTREAM A CTRL response and an X12 acknowledgment cannot be configured simultaneously. Configure these response documents separately.
TIBCO-BW-PALETTE-EDI-503006

For document level validation, doconly_parameters parameter must be supplied.

errorRole EDI-Plug-in ERROR_INSTREAM The Document Level Validation checkbox is selected on the General tab but no Separators were specified. Uncheck Document Level Validation checkbox

OR

Specify separators. Refer to document_only_parameters field in Instream.

TIBCO-BW-PALETTE-EDI-503007

Invalid output directory [{0}].

errorRole EDI-Plug-in ERROR_INSTREAM A valid output directory is required. Specify a valid output directory.
TIBCO-BW-PALETTE-EDI-506000

Unsupported encoding [{0}].

errorRole EDI-Plug-in ERROR_X12PRESCANNER The specified encoding option is not supported. Ensure a supported encoding type is selected: UTF-8, UTF-16, UTF-16BE, UTF-16LE, ISO-8859-1.
TIBCO-BW-PALETTE-EDI-506001

Invalid EDI document.

errorRole EDI-Plug-in ERROR_X12PRESCANNER The specified EDI document is invalid. Supply a valid EDI document for prescanning.
TIBCO-BW-PALETTE-EDI-506100

Unsupported encoding [{0}].

errorRole EDI-Plug-in ERROR_EDIFACTPRESCANNER The specified encoding option is not supported. Ensure a supported encoding type is selected: UTF-8, UTF-16, UTF-16BE, UTF-16LE, ISO-8859-1.
TIBCO-BW-PALETTE-EDI-506101

Invalid EDIFACT document.

errorRole EDI-Plug-in ERROR_EDIFACTPRESCANNER The specified EDIFACT document is invalid. Supply a valid EDIFACT document for prescanning.
TIBCO-BW-PALETTE-EDI-507000

MESSAGE={0}

errorRole EDI-Plug-in ERROR_SHUFFLER This error points to a Shuffler return code.

For example:

TIBCO-BW-PALETTE-EDI-507000:return code [2], error message : STC default file name failed.

Using the return code provided in the message, refer to the Shuffler Return Codes section of the TIBCO Foresight® Instream® MAC Adapter Introduction PDF document.
TIBCO-BW-PALETTE-EDI-507001

Input parameter must be supplied,{0}

errorRole EDI-Plug-in ERROR_SHUFFLER An input file path and name is required. Specify an input file path and name.
TIBCO-BW-PALETTE-EDI-507002

Config parameter must be supplied,{0}

errorRole EDI-Plug-in ERROR_SHUFFLER A configuration file path and name is required. Specify a configuration file path and name.
TIBCO-BW-PALETTE-EDI- 507003

Instream result parameter must be supplied,{0}

errorRole EDI-Plug-in ERROR_SHUFFLER An Instream Detail file path and name is required. Specify an Instream Detail file path and name.
TIBCO-BW-PALETTE-EDI-507004

output file name could not empty.

errorRole EDI-Plug-in ERROR_SHUFFLER An output file name is required. Specify a name for the output file.
TIBCO-BW-PALETTE-EDI-507009

Open STC files {0} failed.

errorRole EDI-Plug-in ERROR_SHUFFLER The specified STC file could not be opened. Ensure the permissions on the file allow open access.
TIBCO-BW-PALETTE-EDI-507010

Open map file {0} failed.

errorRole EDI-Plug-in ERROR_SHUFFLER The specified map file could not be opened. Ensure the permissions on the file allow open access.
TIBCO-BW-PALETTE-EDI-507011

Open instream result file {0} failed.

errorRole EDI-Plug-in ERROR_SHUFFLER The specified Instream result file could not be opened. Ensure the permissions on the file allow open access.
TIBCO-BW-PALETTE-EDI-507012

Read instream result file {0} failed.

errorRole EDI-Plug-in ERROR_SHUFFLER The specified Instream result file could not be read. Ensure the permissions on the file allow open access.
TIBCO-BW-PALETTE-EDI-507013

Parsing input data failed.

errorRole EDI-Plug-in ERROR_SHUFFLER The input data could not be parsed. Ensure input file formatting is valid.
TIBCO-BW-PALETTE-EDI-507014

Parse table {0} failed {1}.

errorRole EDI-Plug-in ERROR_SHUFFLER DEBUG_MESSAGE ONLY N/A
TIBCO-BW-PALETTE-EDI-507015

{0} {1}

errorRole EDI-Plug-in ERROR_SHUFFLER DEBUG_MESSAGE ONLY N/A
TIBCO-BW-PALETTE-EDI-507017

Open output file {0} failed.

errorRole EDI-Plug-in ERROR_SHUFFLER The specified output file could not be opened. Ensure the permissions on the file allow open access.
TIBCO-BW-PALETTE-EDI-508000

{0}Config parameter must be supplied.

errorRole EDI-Plug-in ERROR_ERRORREFINER A configuration file path and name is required. Specify a file path and name for the configuration file.
TIBCO-BW-PALETTE-EDI-508001

Input parameter must be supplied.

errorRole EDI-Plug-in ERROR_ERRORREFINER An input file path and name is required. Specify a file path and name for the input file.
TIBCO-BW-PALETTE-EDI-508002

INVALIDARGUMENT_MESSAGE={0}

errorRole EDI-Plug-in ERROR_ERRORREFINER One or more arguments are invalid. Refer to the supporting text, which appears in {0} for more information.
TIBCO-BW-PALETTE-EDI-508003

File {0} could not be opened.

errorRole EDI-Plug-in ERROR_ERRORREFINER The specified file could not be opened. Ensure the permissions on the file allow open access.
TIBCO-BW-PALETTE-EDI-508004

IOException {0}.

errorRole EDI-Plug-in ERROR_ERRORREFINER An IOException occurred. This is an internal product error. Contact TIBCO Support.
TIBCO-BW-PALETTE-EDI-508005

{0}

errorRole EDI-Plug-in ERROR_ERRORREFINER This error points to a ISErrorRefiner return code.

For example:

TIBCO-BW-PALETTE-EDI-508005:return code [4], InStream results file must start with a VERsion record. (at line # n)"

Using the return code provided in the message, refer to the ISErrorRefiner Return Codes section of the ISErrorRefiner PDF document.
TIBCO-BW-PALETTE-EDI-508006

Illegal severity value {0} found in input file. Unable to continue.

errorRole EDI-Plug-in ERROR_ERRORREFINER The input file contains one or more invalid Error Severity codes. Analyze the input file for invalid Error Severity codes (i.e., codes less than zero or greater than 6).
TIBCO-BW-PALETTE-EDI-508007

Illegal type value {0} found in input file. Unable to continue.

errorRole EDI-Plug-in ERROR_ERRORREFINER The input file contains one or more invalid HIPAA Type codes. Analyze the input file for invalid HIPAA Type codes (i.e., codes less than zero or greater than 8).
TIBCO-BW-PALETTE-EDI-508008

STRUCT={0}

errorRole EDI-Plug-in ERROR_ERRORREFINER A structure-related error has occurred. Refer to the supporting text, which appears in {0} for more information.
TIBCO-BW-PALETTE-EDI-508009

RESULTFILE={0}

errorRole EDI-Plug-in ERROR_ERRORREFINER A result file-related error has occurred. Refer to the supporting text, which appears in {0} for more information.
TIBCO-BW-PALETTE-EDI-508010

Error on loading configure file {0}

errorRole EDI-Plug-in ERROR_ERRORREFINER The specified configuration file could not be loaded. Ensure the configuration file is valid.
TIBCO-BW-PALETTE-EDI-508011

Access configure file {0} failed.

errorRole EDI-Plug-in ERROR_ERRORREFINER The specified configuration file could not be accessed. Ensure the configuration file appears in the specified location.
TIBCO-BW-PALETTE-EDI-508020

The output directory is required.

errorRole EDI-Plug-in ERROR_ERRORREFINER An output directory is required. Specify a valid output directory.
TIBCO-BW-PALETTE-EDI-509000

Input parameter must be supplied.

errorRole EDI-Plug-in ERROR_DOCSPLITTER No Input Mode parameter was selected. Select an Input Mode parameter: File or Memory.
TIBCO-BW-PALETTE-EDI-509001

InstreamResult parameter must be supplied.

errorRole EDI-Plug-in ERROR_DOCSPLITTER An Instream Detail file path and name is required. Specify a file path and name for the Instream Detail file.
TIBCO-BW-PALETTE-EDI-509002

{0}

errorRole EDI-Plug-in ERROR_DOCSPLITTER This error points to a DocumentSplitter return code.

For example:

TIBCO-BW-PALETTE-EDI-509002 :return code [205], Docsplitter could not open the INI config file.

Using the return code provided in the message, refer to the DocumentSplitter Return Codes section of the Document Splitter PDF document.
TIBCO-BW-PALETTE-EDI-509003

Output parameter must be supplied.

errorRole EDI-Plug-in ERROR_DOCSPLITTER No Output Mode parameter was selected. Select an Output Mode parameter: File or Memory.
TIBCO-BW-PALETTE-EDI-509004

Invalid output directory {0}.

errorRole EDI-Plug-in ERROR_DOCSPLITTER The specified output directory is invalid. Specify a valid output directory.