forcestart
This command forces the EMS server instances on the fault tolerant pair of appliances to transition from the wait-for-peer to active-standalone state.
forcestart
When activated, the EMS server begins serving clients even when its fault tolerant peer is not available.
Before you can use this command, the appliance must be in the wait-for-peer state. For details on states, see TIBCO Enterprise Message Service Server States.
Under normal circumstances, an EMS server instance starts automatically when the appliance is powered on. However, the server instance will not start if the appliance is unable to synchronize with its peer.
This command is used to activate an EMS server instance in a fault tolerant pair when the connection to the other appliance is unavailable. This command should only be used to activate a server instance when the other machine in the fault tolerant pair cannot be made available and this machine is in the wait-for-peer state. If the fault tolerant pair is in any other state, this command will not be accepted. Furthermore, this skips any file synchronization between the two machines, resulting in the loss of any new data on the peer.