Failover Events

The events that result in a failover, and the response to each event by the primary and secondary EMS server instances are described in this section.

Event Active EMS Instance Reaction Standby EMS Instance Reaction
Failure of the active EMS server instance, other than a write failure. The EMS server attempts to restart and synchronize with the activated standby server. Activates the EMS server instance and begins local writes.
Failure of the active EMS server hardware. n/a Activates the EMS server instance and begins local writes.
Failure of the standby EMS server hardware. Performs local writes only. n/a
An internal system error on the active appliance. Stops the EMS server instance. Activates the EMS server instance and begins local writes.
An internal system error on the standby appliance. Performs local writes only. Cannot be activated.
Active EMS server local write fails. Stops the EMS server instance. Activates the EMS server instance and begins local writes.
Standby EMS server local write fails. Performs local writes only. The EMS server restarts.
Failure of the standby EMS server, other than write failure. Performs local writes only. The EMS server attempts to restart and synchronize with the active server.