WQDJMS_PORTNO
Activity Monitoring and Work Queue Delta Configuration
Summary
This attribute defines the port number that is used for work queue delta message communications between the WIS
processes and the IAPJMS
process. It is read when iProcess Engine starts up.
Applies To
The attribute should be set for ALL processes.
Default Value
The attribute is assigned the following default value when iProcess Engine is installed.
Machine ID |
Process |
Instance |
Value |
0 |
ALL |
0 |
9075 |
Notes
If you change the value of this attribute, the change does not take effect until you stop and restart iProcess Engine.