1601
FATAL ERROR <start_case: Reached maximum case number> <ProcName>
or
Changed at v11: Keith T review email
FATAL ERROR <FuncName> <Maximum REQID reached>
Description
An iProcess system limit has been reached. Either:
| • | The maximum number of cases has been reached, when trying to start a new case of procedure ProcName. |
or
| • | The maximum number of request ids (REQID) has been reached, by function FuncName, when trying to either start a case or send out a new work item. |
Appears In
SWDIR\logs\sw_error
Severity
1 (Critical)
Action
Investigate the error immediately. Contact TIBCO Support for further assistance.
See Also
"Sequence Number Caching" in TIBCO iProcess Engine Administrator's Guide for more information about REQIDs.