1978
(Value):SW_WISINST value (Value) doesn't match already allocated WIS (WISInstance)
Description
This message is generated by the WQS process when there is a mismatch between the WISIntance that is currently handling a queue and the Value of the SW_WISINST attribute. The SW_WISNST attribute is used to specify a WISinstance that a work queue is to be handled by. On a MOVESYSINFO the value of SW_WISINST is checked for all queues. For existing queues that are already being handled by a WIS process, any mismatch between the value of the SW_WISINST attribute and the WIS process handling it, is logged.
This message is for information only. It's to inform the administrator of the system that a queue is not being handled by the WISinstance that the SW_WISINST attribute Value is set to. There is no action that you can take as you cannot move a queue from one WIS process to another.
Appears In
SWDIR\logs\sw_warn
Severity
3 (Warning)
Action
No action required.
See Also
“Controlling the Assignment of Queues to WIS Processes” in the TIBCO iProcess Engine: Administrator's Guide, for information about different methods of assigning queues to WIS processes.