Chapter 12 Administering the Work Queue Server and Work Item Server Processes : Troubleshooting Work Queues

Troubleshooting Work Queues
This section provides troubleshooting information for when users have problems accessing work queues.
When experiencing problems with the WIS processes, there are three common error messages that appear in the Work Queue Manager:
Failed to Open Work Item List for Queue
or
Work Queue Servers Not Responding
when moving between queues in Work Queue Manager, and
That Facility is Not Available
when attempting to start a case.
In these examples, the client is unable to contact the WIS or WQS process to find out what queues or work items exist. The problem is that users are unable to access their work items in the queues because the work queues are grayed out in Work Queue Manager.
To resolve the problem, try one of the following:
Use plist -w to check the status of each WIS process.
Check to make sure that the WQS and WIS processes are running:
On UNIX, run the ps -fe command.
The processes are named wisrpc and wqsrpc.
Use the swsvrmgr Process Sentinels command line utility, which is under the SWDIR\util directory, to report the status of the processes. See View Process Status.
Check the sw_warn and sw_error files, which is located in the SWDIR\logs directory, for any error messages to see if any problems have been logged. See iProcess Engine Log Files for more information.