Preconfigured System Alerts
System Alerts notify you when system health and status criteria exceed the acceptable bounds.
All LogLogic appliances include several system alerts that are preconfigured and enabled. By default, these alerts have:
- Email notifications sent to the appliance admin user
- Priority set to high
- Default reset time of 300 seconds except (TCP Forward Falling Behind alert has a default reset time of 3600 seconds)
All these alert settings can be customized as needed.
Alert | Description | Default |
---|---|---|
System Alert - CPU Temperature | The temperature of the appliance CPU has exceeded the specified High Threshold | 70 degrees Celsius |
System Alert - Disk Usage | The usage of the specified drive on the appliance has exceeded the specified High Threshold | 80% |
System Alert - Dropped Message | The number of messages dropped by the appliance has exceeded the specified High Threshold | 10 msg/sec |
System Alert - Fail Over | A failover has occurred on the appliance | n.a. |
System Alert - Migration Complete | A data migration involving the appliance is successfully complete | n.a. |
System Alert - Network Connection Speed | The speed of the network connection for the appliance has become lower than the specified Low Threshold | 10-Half |
System Alert - Network Interface | A problem occurred with the appliance network interface | n.a. |
System Alert - RAID Disk Failure | A failure occurred on an appliance RAID disk | n.a. |
System Alert - Synchronization Failure | A failure occurred during log data synchronization on the appliance | n.a. |