Define - RV Interface Details

From the Define - Interfaces: RV page, click Add or double-click an existing RV interface, the RV Interface Details page is displayed.

The following table describes the items that are available on the RV Interface Details page:

Item Description
Name Type an RV interface name.
Description Type a short description for the RV interface.
Interface ID Type an interface ID.
Workers Enter the number of worker tasks for each listener.

Valid values for this field are in the range 0 - 40.

The default value is 5, and the value of 0 indicates that no worker is assigned.

Workers (End of Task)

Enter the number of End of Task (EOT) concurrent worker threads that are started to service the Substation ES UoW termination requests.

Valid values for this field are in the range 2 - 40.

The default value is 30.

Message Free List Size Enter the value to dynamically set the messages free list size.
Suspend Services If you want to turn on the suspended function for this ESB interface, select this check box.

By default, this check box is selected.

Enable message receipt If you want to listen to the Rendezvous messages being delivered to a subject or destination, which is defined at configuration time, select this check box.

By default, this check box is selected.

Enable message delivery If you want to send Rendezvous messages to a subject or destination, which is defined at configuration time, select this check box.

By default, this check box is selected.