Define - Admin Interface Details

From the Define - Interfaces: Admin page, click Add or double-click an existing Admin interface, and then the Admin Interface Details page is displayed.

The following table describes the items that are available on the Admin Interface Details page:

Item Description
Name Type an Admin interface name.
Description Type a short description for the Admin interface.
Interface ID Type a Substation ES interface identifier.
Admin Endpoint Type an Admin endpoint name, or click the icon to select one.
Workers Enter the number of concurrent internal threads that service Substation ES administration performance.

Valid values for this field are in the range 1 - 30.

The default value is 3.

Trace Level: Operational Commands Enter the trace level of the messages produced for a Substation ES operational command.
Log Remote Commands If you want to log remote operational commands to the Substation log file, select this check box.
In the Heartbeat area, the following items are available:
Interval (sec) Enter the heartbeat trigger message publish rate.

Valid values for this field are in the range 0 - 300 seconds.

The value of 0 stops the heartbeat trigger service.

Service: Trigger Type the trigger service name used for the heartbeat message, or click the icon to select one.
Output Interface Type an output interface, or click the icon to select one.
Heartbeat Command Type the CONSOLE command that the heartbeat trigger message publishes. Up to five commands can be specified.