Node
User Profile
Responder Profile
|
The following definitions are checked:
- The server credential for the TIBCO MFT Command Center user for that TIBCO MFT Command Center server.
- The Server Credentials section of the server definition on the
Add Server page.
If user ID and password are not defined in the above definitions, the request terminates with an error.
|
Transfer
|
The following definitions are checked:
- The
Initiator User Id and
Initiator Password parameters in the Credentials and Security Properties section of a Platform transfer definition on the
Add/Execute Platform Transfer page.
- The server credential for the
TIBCO MFT Command Center user for that
TIBCO MFT Command Center server.
- The Server Credentials section of the server definition.
If user ID and password are not defined in the above definitions, the request terminates with an error.
|
Platform Server Manual Poll
|
The following definitions are checked:
- The server credential for the
TIBCO MFT Command Center user for that
TIBCO MFT Command Center server.
- The Server Credentials section of the server definition.
If user ID and password are not defined in the above definitions, the request terminates with an error.
|
Collector
|
The following definitions are checked:
- The server credential for the user Collector for that
TIBCO MFT Command Center server.
- The Server Credentials section of the server definition.
If user ID and password are not defined in the above definitions, the request terminates with an error.
|