TIBCO Hawk Agent Running Condition Configuration

In the TIBCO Hawk Running condition window, enter values in each field.

TIBCO Administrator and Hawk Agent Running Conditions
Polling Period (in seconds) for detection of TIBCO Hawk Agent running verification (required)
Enter an integer to specify the number of seconds between periodic verification checks that the TIBCO Hawk Agent is still running. 
If the TIBCO Hawk Agent becomes unresponsive to this verification, the process is automatically restarted.

The running condition check might be disabled with a value of 0.

Automatically Restart Silver Fabric Engine if TIBCO Hawk Agent fails to restart N successive times (required)
Enter an integer to specify the number of restart retries for the TIBCO Hawk Agent before you restart the TIBCO Silver Fabric engine enabler. A successful restart resets the count.

The automatic restart might be disabled with a value of 0.

Force kill of TIBCO Hawk agent process by engine daemon on shutdown (If the regular stop is not successful)
Use this option, only if the regular stop does not work. Select this option if you want to kill all the TIBCO Hawk Agent processes on shutdown. It stops all those processes which were started by the engine daemon.