Configure TIBCO Hawk Agent Running Condition

Polling Period (in seconds) for detection of TIBCO Hawk Agent running verification (required)
Enter an integer to specify the number of seconds between periodic verification checks that the TIBCO Hawk Agent is still running. 
If the TIBCO Hawk Agent becomes unresponsive to this verification then the process is automatically restarted.
Automatically Restart Silver Fabric Engine if TIBCO Hawk Agent fails to restart N successive times (required)
Enter an integer to specify the number of restart retries for the TIBCO Hawk Agent before the TIBCO Silver Fabric engine is restarted. A successful restart resets the count.
Force Kill of TIBCO Hawk Agent Process by Engine Daemon on Shutdown (if the regular stop is not successful)
If the regular stop does not work, then only use this option. Select this option if you want kill all the TIBCO Hawk Agent processes on shutdown. It stops all those processes those were started by engine daemon.