Spotfire® User Guide

ParallelCoordinatePlot preferences

Preferences that an administrator can specify for the parallel coordinate plot.

Preference Description
AutoConfigureAggregationLimitHigh

Specifies the number of rows at which automatic (default) configuration of parallel coordinate plots should start using aggregation for users running the installed Spotfire client.

Default limit is 500000.

AutoConfigureAggregationLimitLow

Specifies the number of rows at which automatic (default) configuration of parallel coordinate plots should start using aggregation for users running the Spotfire web client.

This limit is generally set to a lower value than the high limit used elsewhere in order to improve the response time of the Spotfire web clients.

Default limit is 4000.

BreakLinesOnEmptyValues Specifies whether lines should be broken or remain connected when an empty value is found in the data used to create the line.
Default Title Specifies the default title of new parallel coordinate plots. For example, Parallel Coordinate Plot.
LegendVisible Specifies whether the legend should be shown when creating a new parallel coordinate plot.
LineWidth Specifies the width (in pixels) of the lines in the parallel coordinate plot.

Enter a value between 1 and 10.

UseSeparateColorForMarkedItems Specifies whether the parallel coordinate plot should use a separate color for marked items or just dim the unmarked items.