Configuring TIBCO Hawk Agent Running Condition

Set the polling period in number of seconds for checking that the TIBCO Hawk Agent is properly responding. If the TIBCO Hawk Agent fails to restart after the specified number of attempts then the TIBCO Silver Fabric Engine will be restarted automatically.

Procedure

  • In the TIBCO Hawk Agent Running Condition window, enter values in each field.
    TIBCO Hawk Agent Running Conditions

    The configuration parameters in the TIBCO Hawk Agent Running Condition window are as described.

    • Polling Period (in seconds) for detection of TIBCO Hawk Agent running verification (required)
      Enter an integer to specify the number of seconds between periodic verification checks that the TIBCO Hawk Agent is still running. 
If the TIBCO Hawk Agent becomes unresponsive to this verification then the process is automatically restarted.
    • Automatically Restart Silver Fabric Engine if TIBCO Hawk Agent fails to restart N successive times (required)
      Enter an integer to specify the number of restart retries for the TIBCO Hawk Agent before the TIBCO Silver Fabric Engine will be restarted. A successful restart will reset the count.
    • Force kill of TIBCO Hawk agent process by engine daemon on shutdown (If the regular stop is not successful)

      Use this option only if the regular stop does not work. Select this option if you want to kill all the TIBCO Hawk Agent processes on shutdown. It stops all those processes which were started by the engine daemon.