Graceful shutdown configuration settings
Before you make a configuration change or an upgrade that causes Spotfire Server to shut down, consider enabling the following settings to control the shutdown behavior.
A graceful shutdown can be initiated explicitly with a call to graceful-shutdown, or it can be initiated by the server due to a change in the configuration. If the shutdown is initiated as a result of a detected change or upgrade, then the server checks for the following settings.
| Setting | Description |
|---|---|
lifecycle.changes-monitoring.interval-seconds
|
0 or a negative value
disables changes to monitoring. The default is
-1.
|
lifecycle.changes-monitoring.database-schema-change-action
|
Can be set to
IGNORE,
GRACEFUL_SHUTDOWN, or
IMMEDIATE_SHUTDOWN. The default is
IGNORE.
|
lifecycle.changes-monitoring.technical-version-change-action
|
Can be set to
IGNORE,
GRACEFUL_SHUTDOWN, or
IMMEDIATE_SHUTDOWN. The default is
IGNORE.
|
lifecycle.changes-monitoring.configuration-change-action
|
Can be set to
IGNORE,
GRACEFUL_SHUTDOWN, or
IMMEDIATE_SHUTDOWN. The default is
IGNORE.
|
lifecycle.changes-monitoring.draining.minimum-seconds
|
The minimum draining period, in seconds. The
default is
60.
|
lifecycle.changes-monitoring.draining.timeout-seconds
|
The maximum timeout for draining, in seconds.
The default is
120.
|
lifecycle.changes-monitoring.draining.shutdown
|
Specifies whether an immediate shutdown
should be performed at the end of the draining period. The default is
true.
|
For a cluster installation, you can use the following settings to control a rolling shutdown.
| Setting | Description |
|---|---|
lifecycle.changes-monitoring.draining.rolling.enabled
|
Set to
true to enable rolling shutdown of a Spotfire
Server cluster. The default is
false.
|
lifecycle.changes-monitoring.draining.rolling.maxwait-seconds
|
The maximum timeout for draining, in seconds.
The default is
lifecycle.changes-monitoring.draining.timeout-seconds.
|
lifecycle.changes-monitoring.draining.rolling.semaphore-retry-seconds
|
The default is
5.
|
lifecycle.changes-monitoring.draining.rolling.max-unavailable
|
The default is
1.
|
A rolling shutdown should have, at the most, the value of
lifecycle.changes-monitoring.draining.rolling.max-unavailable