MSA Attribute Data - Acceptance Options Tab
Select the Acceptance options tab of the MSA Attribute data dialog box to access the options described here.
- Effectiveness
- Select the appropriate equality operator (< , < = , >, >=) and enter the appropriate threshold value for acceptable and unacceptable effectiveness.
- P(FR)
- Select the appropriate equality operator (< , < = , >, >=) and enter the appropriate threshold value for acceptable and unacceptable probability of false rejection.
- P(FA)
- Select the appropriate equality operator (< , < = , >, >=) and enter the appropriate threshold value for acceptable/unacceptable probability of false acceptance.
- Bias
- Select the appropriate equality operator (< , < = , >, >=) and enter the appropriate threshold value for acceptable and unacceptable bias.