SPC Charts - Run Rules Types 1

Use this tab to define the following parameters:

Element Name Description
On the same side of center line (Zone C or beyond) Select this checkbox to test for samples in a row on the same side of the center line in or beyond Zone C ( or Type 1 Runs Rule violation).
One the same side of center line (Zone C or beyond) value Use this miniscroll to select the minimum number of samples in a row to trigger a same side of center line in or beyond Zone C Runs Rule violation.
One the same side of center line (beyond Zone C) Select this checkbox to test for samples in a row on the same side of the center line beyond Zone C ( or Type 8 Runs Rule violation).
One the same side of center line (beyond Zone C) value Use this miniscroll to select a value for the minimum number of samples in a row to trigger a same side of center line and beyond Zone C Runs Rule violation.
Increasing or decreasing tend Select this checkbox to test for samples in a row showing increasing or decreasing trend ( or Type 2 Runs Rule violation).
Increasing or decreasing tend value Use this miniscroll to select a value for the minimum number of samples in a row showing increasing or decreasing trend to trigger a Runs Rule violation.
Alternating up and down Select this checkbox to test for samples in a row showing alternating up and down trend ( or Type 3 Runs Rule violation).
Alternating up and down value Use this miniscroll to select a value for the minimum number of samples in a row showing alternating up and down trend to trigger a Runs Rule violation.