X and MR Chart for Variables, SixGraph Summary

Creates an X (individual observations) and MR (moving range) chart for each variable in the input descriptor continuous dependent Variable list. You can set the center line for the X-bar chart and sigma; also computes SixGraph summary and short-run charts.

 Short-run charts can also be computed; if a categorical variable is specified in the input descriptor, then that variable will be used to assign samples to parts; otherwise always k (as specified by the user) consecutive samples will be assigned to consecutive parts.

Element Name Description
General
Detail of computed results reported Specifies the level of computed results reported. By default, the respective chart summary is reported. If All results is requested, spreadsheet summaries for each chart and outlier summaries are also computed and reported in results spreadsheets.
Type of X chart Type of X chart for individuals (sigma will be estimated from moving ranges).
Short run chart Specifies whether the current chart is a short-run chart for multiple parts; if so, STATISTICA will either assign samples to parts based on the specified fixed number of samples per part, or take the second categorical predictor variable (if one is specified) to assign samples to parts.
Number of samples per part Number of samples per part (for short-run charts); if a categorical predictor variable is specified, STATISTICA will determine the assignment of samples to parts from the integer codes found in that variable; otherwise, STATISTICA will use this parameter to assign consecutive k samples to parts.
X Chart Specs
Applies user-defined centerline Applies user-defined centerline value for the X chart; if false, compute the centerline value from the data (mean).
User-defined centerline value User-defined centerline value for X chart.
Applies user-defined sigma Applies user-defined value for sigma to the X chart; if false, estimate sigma from the data via moving range.
User-defined sigma value User-defined value of sigma (will automatically compute center line value for X chart).
Specify limits as Specify how to set (compute) the control and warning limits for the chart, i.e., in terms of multiples of Sigma, computed from probability values, or as a constant. Then set the values below accordingly.
Lower control limit X Lower control limit for X chart; specify either in multiples of sigma, as p value, or as a constant, depending on the setting of the Specify-limits-as option.
Upper control limit X Upper control limit for X chart; specify either in multiples of sigma, as p value, or as a constant, depending on the setting of the Specify-limits-as option.
Show warning lines (X) Show warning lines in the X chart
Lower warning limit X Lower warning limit for X chart; specify either in multiples of sigma, as p value, or as a constant, depending on the setting of the Specify-limits-as option.
Upper warning limit X Upper warning limit for X chart; specify either in multiples of sigma, as p value, or as a constant, depending on the setting of the Specify-limits-as option.
MR Chart Specs
Specify limits as Specify how to set (compute) the control and warning limits for the chart, i.e., in terms of multiples of Sigma, computed from probability values, or as a constant. Then set the values below accordingly.
Lower control limit MR Lower control limit for MR chart; specify either in multiples of sigma (MR), as p value, or as a constant, depending on the setting of the Specify-limits-as option.
Upper control limit MR Upper control limit for MR chart; specify either in multiples of sigma (MR), as p value, or as a constant, depending on the setting of the Specify-limits-as option.
Show warning lines (MR) Show warning lines in the MR chart.
Lower warning limit MR Lower warning limit for MR chart; specify either in multiples of sigma (MR), as p value, or as a constant, depending on the setting of the Specify-limits-as option.
Upper warning limit MR Upper warning limit for MR chart; specify either in multiples of sigma (MR), as p value, or as a constant, depending on the setting of the Specify-limits-as option.
Process Capability
Creates Cpk, Ppk, etc. Creates process capability and performance indices (summaries).
Type of specification limits Type of specification limits: Two-sided: Nominal plus/minus delta; Nominal, lower, Upper; One-sided: Lower, nominal; Nominal, upper.
Nominal value (for spec limits) Nominal value, for process capability computations.
Delta value (for spec limits) Value of delta, for defining specification limits as nominal plus/minus delta.
Lower specification limit Lower specification limit; not applicable if Type of specification limits is equal to Nominal Upper (one-sided).
Upper specification limit Upper specification limit; not applicable if Type of specification limits is equal to Lower Nominal (one-sided).
Show specs in chart Show process specification limits in the X or X-bar chart.
Displays
Runs tests Select whether or not to compute runs tests, and if so, whether or not to indicate violations of runs tests in the charts.
Formats for values on axes Select how to determine the display format of scale (axis) labels in control charts; choose From variable formats to format the scale (axis) labels using the display format of the respective variable in the plot; use Number of digits to specify a fixed number of digits for the display format.
Number of digits for scale Specifies the number of digits for the display format, for scale (axis) labels in charts; this options is only applicable if the Formats for values on axes option is set to Number of digits.
Number of digits values Specifies the number of digits to be used for displaying numbers (values other than scale or axes values for charts) in various charts and results tables.
Process capability, n of digits Specifies the number of digits to be used for displaying process capability indices and related statistics.
Separate parts in charts If true, consecutive samples belonging to different parts (in short-run charts) will be separated by vertical lines; not applicable for standard (non short-run) charts.
Label parts in charts If true, samples belonging to different parts (in short-run charts) will be labeled with the part names; not applicable for standard (non short-run) charts.