File Writer Output Adapter

Introduction

The Spotfire Streaming File Writer output adapter takes in tuples and can write either the entire tuple as a string to the file or can be set to write a single field of the tuple to the current file.

The adapter can be configured to open a file for writing on start-up.

The adapter has samples, described in File Writer Output Adapter Samples.

File Writer Properties

This section describes the properties you can set for this adapter, using the various tabs of the Properties view in StreamBase Studio.

General Tab

Name: Use this required field to specify or change the name of this instance of this component. The name must be unique within the current EventFlow module. The name can contain alphanumeric characters, underscores, and escaped special characters. Special characters can be escaped as described in Identifier Naming Rules. The first character must be alphabetic or an underscore.

Adapter: A read-only field that shows the formal name of the adapter.

Class name: Shows the fully qualified class name that implements the functionality of this adapter. If you need to reference this class name elsewhere in your application, you can right-click this field and select Copy from the context menu to place the full class name in the system clipboard.

Start options: This field provides a link to the Cluster Aware tab, where you configure the conditions under which this adapter starts.

Enable Error Output Port: Select this checkbox to add an Error Port to this component. In the EventFlow canvas, the Error Port shows as a red output port, always the last port for the component. See Using Error Ports to learn about Error Ports.

Description: Optionally, enter text to briefly describe the purpose and function of the component. In the EventFlow Editor canvas, you can see the description by pressing Ctrl while the component's tooltip is displayed.

Adapter Properties Tab

Property Description
Default File Name The default file name to create on start-up. If no file is specified the control port must be enabled to send control tuples to open a file for writing.
Data Field The field from the incoming data port to write to the file. If left blank the entire tuple will be written as a string.
FileName Field The field from the incoming data to use to determine which file to write data to. This option is only valid when Enable Multiple Open Files is used.
Enable Control Port If checked this enables the control port, which allows the user to send control commands to open, flush, and close files.
Enable Status Port If checked this will enable the status port, which gives information about what actions are being taken against files.
Write Line Separator After Tuple If checked this will write the system new line character after each tuple is received and written to the file.
File Create Mode This determines how a file will be created:
  1. Append: If the file exists, its contents will remain and the new data is appended at the end.

  2. Overwrite: If the file exists, its contents are overwritten.

  3. Fail: If the file exists, a Reject status tuple is emitted and the file will not be opened for writing.

File Compression This determines how a file will be compressed when written:
  1. None: The file will be written with no compression.

  2. GZip: The file will be written with the GZip compression format.

  3. BZip2: The file will be written with the BZip2 compression format.

  4. Zip: The file will be written with the standard Zip format and contain a single entry with the same name as the file name you specify, minus the extension.

Flush Interval The value in milliseconds to perform a flush on the file to write out any buffered data. A value of 0 means a flush is performed after each tuple is received.
Synchronized Open Command If enabled the operator will perform the open command and wait for it to complete before continuing.
Synchronized Close Command If enabled the operator will perform the close command and wait for it to complete before continuing.
Synchronized Flush Command If enabled the operator will perform the flush command and wait for it to complete before continuing.
Synchronized Write Command If enabled the operator will perform the write command and wait for it to complete before continuing.
Enable Multiple Open Files If enabled the operator will allow multiple files open at the same time. This option requires that every command has a filename associated.
Log Level Controls the level of verbosity the adapter uses to send notifications to the console. This setting can be higher than the containing application's log level. If set lower, the system log level is used. Available values, in increasing order of verbosity, are: OFF, ERROR, WARN, INFO, DEBUG, TRACE.

Cluster Aware Tab

Use the settings in this tab to enable this operator or adapter for runtime start and stop conditions in a multi-node cluster. During initial development of the fragment that contains this operator or adapter, and for maximum compatibility with releases before 10.5.0, leave the Cluster start policy control in its default setting, Start with module.

Cluster awareness is an advanced topic that requires an understanding of StreamBase Runtime architecture features, including clusters, quorums, availability zones, and partitions. See Cluster Awareness Tab Settings on the Using Cluster Awareness page for instructions on configuring this tab.

Concurrency Tab

If is highly suggested to not use this feature with this adapter.

Use the Concurrency tab to specify parallel regions for this instance of this component, or multiplicity options, or both. The Concurrency tab settings are described in Concurrency Options, and dispatch styles are described in Dispatch Styles.

Caution

Concurrency settings are not suitable for every application, and using these settings requires a thorough analysis of your application. For details, see Execution Order and Concurrency, which includes important guidelines for using the concurrency options.

Description of This Adapter's Ports

The File Writer adapter's ports are used as follows:

  • Data (input): Tuples are received on this port and written to the current file. The schema for this port can be anything.

  • Control (input): Tuples enqueued on this port cause the adapter to perform actions on files. The schema for this port has the following fields:

    • Command, string. The command to perform:

      1. Open: Open a file for written with the options given.

      2. Close: Close the currently open file.

      3. Flush: Force a flush operation on the current file to write out any buffered data.

    • FileName, string. Required by the Open command. The name of the file to open.

    • CreateMode, string. Determines how a file will be created. If null this remains unchanged and the last value loaded is used:

      1. Append: If the file exists its contents will remain the new data will be appended at the end.

      2. Overwrite: If the file exists its contents will be overwritten.

      3. Fail: If the file exists a Reject status tuple will be emitted and the file will not be opened for writing.

    • Compression, string. Determines how a file will be compressed when written. If null this remains unchanged and the last value loaded is used:

      1. None: The file will be written with no compression.

      2. GZip: The file will be written with the GZip compression format.

      3. BZip2: The file will be written with the BZip2 compression format.

      4. Zip: The file will be written with the standard Zip format and contain a single entry with the same name as the file name you specify minus the extension.

    • FlushInterval, int. The value in milliseconds to perform a flush on the file to write out any buffered data. If null this remains unchanged and the last value loaded is used.

    • WriteLineSeparator, boolean. Determines if the system new line character will be written after each tuple is received. If null this remains unchanged and the last value loaded is used.

  • Status (output): The adapter emits tuples from this port when significant events occur, such as when an attempt to open, flush, or close a file occurs. The schema for this port has the following fields:

    • Type, string: returns one of the following values to convey the type of event:

      • User Input

      • System

    • Action, string: returns an action associated with the event Type:

      • Rejected

      • Open

      • Close

      • Flush

      • Error

    • Object, string. Returns an event type-specific value, such as the name of the file which a open failed or the control input tuple that was rejected.

    • Message, string. Returns a human-readable description of the event.

    • Time, timestamp. Returns the time this event occurred.

    • InputTuple, tuple. Returns a combined data and control tuple which was used during this event.

Typechecking and Error Handling

The File Writer adapter uses typecheck messages to help you configure the adapter within your StreamBase application. In particular, the adapter generates typecheck messages for the following reasons:

  • The Control Input Port does not have the required schema.

  • The field specified in the data field does not exists in the incoming data schema.

  • The flush interval is not an integer value greater than or equal to 0.

  • The Default File Name property is blank and the control port is disabled.

  • The compression mode is Zip and the file create mode is Append.

Suspend and Resume Behavior

When suspended, the adapter stops processing requests to write files.

When resumed, the adapter once again starts processing requests to write files.

Related Topics