Spotfire Streaming provides a Logback appender for Windows, which is configured using the standard Logback configuration mechanisms. The supported appender configuration values are shown in the following table.
Configuration Value | Description | Required? |
---|---|---|
application
|
Application name for logged events. |
No. Default value is Application .
|
class
|
Log appender class name. Must be set to com.tibco.ep.dtm.logappenders.windowseventlogger.WindowsEventLoggerAppender .
|
Yes. |
layout
|
LogBack appender layout. See the LogBack layout documentation. | Yes. |
server
|
Windows UNC name of the remote log server. | No. Default is local machine's log server. |
source
|
Event source name. | Yes. |
The following is an example of a Logback configuration for an Windows event log appender:
<appender name="win-appender" class="com.tibco.ep.dtm.logappenders.windowseventlogger.WindowsEventLoggerAppender"> <source>sample.event.source.name</source> <layout class="ch.qos.logback.classic.PatternLayout"> <pattern>d{HH:mm:ss.SSS} %thread %-5level %logger: %msg%n</pattern> </layout> </appender>
The next table shows how Logback log levels are mapped to the Windows Event Log event types.
LogBack Log Level | Windows Event Log Event Type |
---|---|
ERROR | 0x1 |
WARN | 0x2 |
All others | 0x4 |
Logback log levels are also mapped to the Windows Event Logger category identifiers:
LogBack Log Level | Windows Event Log Category Mapping |
---|---|
ERROR | 1 |
WARN | 2 |
INFO | 3 |
INFO | 4 |
TRACE | 5 |