Log Entries Panel

In the Log Entries panel, you can select a log or trace record written to the log or trace disk file.

Panel Layout

SXLP002---------------------- Log Entries ------------------------ Row 1 of 29
Command ===>                                                   Scroll ==> PAGE

Sel  Time      Type   Msg Id    RC  Rsn Message
- ------------- ---- -------- ---- ---- --------------------------------------
  11:09:54.0919 154  SXG1600I    0    0 Log Agent Starting - Logging to TIBLOG
  11:09:54.1126 154  SXG1800I    0    0 Parameter Log Agent Starting - Logging
  11:09:54.4368 154  SXS1000I    0    0 Starting ~ TIBCO Substation (ES) for O
  11:09:54.4596 154  SXS1009I    0    0 Substation (ES) - Version 2.0.0
  11:09:54.7894 154  SXG2801I    0    0 Initialized ~ Substation ES - Admin &
  11:09:55.0454 154  SXG2800I    0    0 Starting ~ Substation ES - Transformer
  11:09:55.0479   0  SXT5717I    0    0 Trace level 1, 10 work threads; Cfg:TI
  11:09:55.2871 154  SXG2801I    0    0 Initialized ~ Substation ES - Transfor
  11:09:55.3874 154  SXG2800I    0    0 Starting ~ Substation ES - CICS Interf
  11:09:55.4673 154  SXC3000I    0    0 CICSTS4G - Connect IICICS to CICS Regi
  11:09:55.5539 154  SXC3001I    0    0 CICSTS4G - Connect IICICS to CICS Regi
  11:09:55.5590 154  SXG2801I    0    0 Initialized ~ Substation ES - CICS Int
  11:09:55.5950 156  SXC3400I    0    0 CICSTS4G - Started CICS EXCI Session (
  11:09:55.6130 156  SXC3400I    0    0 CICSTS4G - Started CICS EXCI Session (
  11:09:55.6352 154  SXG2800I    0    0 Starting ~ Substation ES - IMS Interfa
  11:09:55.6612 154  SXI4000I    0    0 A01IMSG - Connect IIIMS to IMS Region
  11:09:55.7283 154  SXI4001I    0    0 A01IMSG - Connect IIIMS to IMS Region
  11:09:55.7326 154  SXG2801I    0    0 Initialized ~ Substation ES - IMS Inte
  11:09:55.7336 154  SXS1001I    0    0 Initialized ~ Substation ES for IVP's
  11:09:55.8350 154  SXG1801I    0    0 Parameter Log closed
  11:09:55.8362 154  SXS2120I    0    0 (B) HiMark:0 Occ:1024 Incr:0 Curr:0
  11:09:55.8363 154  SXS2121I    0    0 (F) Stress Levels Strt:768 Slow:819 St
  11:09:55.8408 154  SXS2120I    0    0 (A) HiMark:410 Occ:1024 Incr:102 Curr:
  11:09:55.8504 154  SXG2806I    0    0 Activated ~ Substation ES - CICS Inter
  11:09:55.8521 154  SXG2806I    0    0 Activated ~ Substation ES - Transforme
  11:09:55.8525   0  SXT5036I    0    0 All transformer tasks are Good To Go
  11:09:55.8525 154  SXG2806I    0    0 Activated ~ Substation ES - Admin & Op
  11:09:55.8531 154  SXG2806I    0    0 Activated ~ Substation ES - IMS Interf
  11:09:55.8610 154  SXG2806I    0    0 Activated ~ Substation ES for IVP's
******************************* Bottom of data ********************************

Field Description

The following table lists the fields in the Log Entries panel:
Field Description
Sel If you specify S or X in the input column, a panel with all the values that relate to the selected message is displayed.

Valid selections: S and X.

Time The time that this message was recorded at by Substation ES LTA Agent.
Type The internal message type code.
Msg Id The message identifier.
RC The return code associated with the message.
Rsn The reason code associated with the message.
Message The initial part of the message description. The entire message is available if you select the panel with all the values that relate to the selected message.