EMS Properties (Trigger) Panel
You can specify up to fifteen EMS properties to be inserted in output messages in the EMS Properties (Trigger) panel.
Panel Layout
Note: You can also specify the
JMSCorrelationID header field,
tibss-BES,
tibss-cfg-id, and
tibss-ss-id in this panel. See
System Fields Used as Property Fields for more information on how to set up Substation ES system fields as property fields.
You can access this panel by entering PROP in the Trigger Details panel. For details, see Trigger Details Panel.
SXTP05PT ----------------- EMS Properties (Trigger) -------- Row 1 to 11 of 15
Command ===> Scroll ==> CSR
Output Buffer Id: New-Buffer1
Property Name B/V Value
-------------------- - ------------------------------------------------------
----------------------------------------------
Property-1 B IVP-BES-PGM-NAME
Property-2 V This is the property field
tibss-BES V $$SYSTEM
tibss-ss-id V $$SYSTEM
____________________ _ ______________________________________________________
______________________________________________
******************************* Bottom of data ********************************
Field Description
The following table lists the fields in the
EMS Properties (Trigger) panel: