| SXT5101E | RV-Type is undefined | 
 
			  
				| Explanation: The Rendezvous Type field is not on the list of fields that can be processed. User Response: Correct the recipe definition. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5102E | RV-ARRAYs are not supported | 
 
			  
				| Explanation: The Rendezvous array types are not supported. User Response: Correct the recipe definition. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5103E | RV-User types are not supported | 
 
			  
				| Explanation: Rendezvous user types are not supported. User Response: Correct the recipe definition. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5104E | Receiving field too short | 
 
			  
				| Explanation: The receiving field is too short for the input data. User Response: Correct the recipe definition or input data. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5105E | Receiving field too long | 
 
			  
				| Explanation: The incoming data field is greater than 8 bytes which is the maximum for a binary number. User Response: Correct the recipe definition or input data. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5106E | Receiving field has invalid length | 
 
			  
				| Explanation: The receiving field has an invalid length. User Response: Correct the recipe definition. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5107E | Numeric overflow | 
 
			  
				| Explanation: The receiving numeric field is too small for the input data. User Response: Correct the recipe definition or input data. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5108E | String or Text overflow | 
 
			  
				| Explanation: The receiving string or text field is too small for the input data. User Response: Correct the recipe definition or input data. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5109E | Input value is not numeric | 
 
			  
				| Explanation: The input value is not numeric. User Response: Correct the recipe definition or input data. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5110E | Input float value invalid | 
 
			  
				| Explanation: The value of a float field is invalid. User Response: Correct the recipe definition or input data. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5111E | Date-Time conversion error | 
 
			  
				| Explanation: An error occurred during the conversion to or from a date-time value. User Response: Correct the recipe definition or input data. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5112E | U64 with high-order bit on | 
 
			  
				| Explanation: U64 with high-order bit is on. User Response: Correct the recipe definition or input data. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5113E | Decimal adjust error | 
 
			  
				| Explanation: An error occurred during the adjustment of the placement of the decimal point. User Response: Correct the recipe definition or input data. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5114E | Input string too large to pack | 
 
			  
				| Explanation: An input string is too large to pack into a packed decimal field. User Response: Correct the recipe definition or input data. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5115E | Packed operation too large | 
 
			  
				| Explanation: A packed value contains too many significant digits. User Response: Correct the recipe definition or input data. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5116E | Unknown buffer field type | 
 
			  
				| Explanation: The buffer definition contains an unknown type field. User Response: Correct the recipe definition. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5117E | Input RV-MSG not supported | 
 
			  
				| Explanation: 
				  RV-MSG is not supported at the field level. User Response: Correct the definition or input data. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5118E | Input ENCRYPT not supported | 
 
			  
				| Explanation: The Rendezvous type 
				  ENCRYPT is not supported. User Response: Correct the definition or input data. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5119E | Input NONE not supported | 
 
			  
				| Explanation: The Rendezvous type 
				  NONE is not supported. User Response: Correct the definition or input data. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5120E | Input XML not supported | 
 
			  
				| Explanation: The Rendezvous type XML is not supported. User Response: Correct the definition or input data. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5121E | Cannot convert OPAQUE to PACKED | 
 
			  
				| Explanation: Conversion of 
				  OPAQUE to 
				  PACKED has failed. User Response: Correct the recipe definition or input data. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5122E | Cannot convert OPAQUE to ZONED DECIMAL | 
 
			  
				| Explanation: Conversion of 
				  OPAQUE to 
				  ZONED DECIMAL has failed. User Response: Correct the recipe definition or input data. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5123E | Cannot convert OPAQUE to UNSIGNED BINARY | 
 
			  
				| Explanation: Conversion of 
				  OPAQUE to 
				  UNSIGNED BINARY has failed. User Response: Correct the recipe definition or input data. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5124E | Cannot convert OPAQUE to BINARY | 
 
			  
				| Explanation: Conversion of 
				  OPAQUE to 
				  BINARY has failed. User Response: Correct the recipe definition or input data. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5125E | Cannot convert OPAQUE to FLOATING POINT | 
 
			  
				| Explanation: Conversion of 
				  OPAQUE to 
				  FLOATING POINT has failed. User Response: Correct the recipe definition or input data. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5126E | Cannot convert IPADDR32 to PACK | 
 
			  
				| Explanation: Conversion of 
				  IPADDR32 to 
				  PACK has failed. User Response: Correct the recipe definition or input data. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5127E | Cannot convert IPADDR32 to ZDEC | 
 
			  
				| Explanation: Conversion of 
				  IPADDR32 to 
				  ZDEC has failed. User Response: Correct the recipe definition or input data. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5128E | Cannot convert IPADDR32 to FLOAT | 
 
			  
				| Explanation: Conversion of 
				  IPADDR32 to 
				  FLOAT has failed. User Response: Correct the recipe definition or input data. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5129E | Cannot convert OPAQUE to U-PACKED | 
 
			  
				| Explanation: Conversion from 
				  OPAQUE to Unsigned packed is not supported. User Response: Correct the conversion rule or input message. 
				   System Action: The conversion is marked as error. 
				   | 
 
			  
				| SXT5130E | Cannot convert OPAQUE to UZ-DEC | 
 
			  
				| Explanation: Conversion from 
				  OPAQUE to Unsigned zoned decimal is not supported. User Response: Correct the conversion rule or input message. 
				   System Action: The conversion is marked as error. 
				   | 
 
			  
				| SXT5131E | Cannot convert IPADDR32 to UPACK | 
 
			  
				| Explanation: Conversion from 
				  IPADDR32 to Unsigned packed is not supported. User Response: Correct the conversion rule or input message. 
				   System Action: The conversion is marked as error. 
				   | 
 
			  
				| SXT5132E | Cannot convert IPADDR32 to UZDEC | 
 
			  
				| Explanation: Conversion from 
				  IPADDR32 to Unsigned zoned decimal is not supported. User Response: Correct the conversion rule or input message. 
				   System Action: The conversion is marked as error. 
				   | 
 
			  
				| SXT5201E | RV-Type is undefined | 
 
			  
				| Explanation: The Rendezvous Type field is not on the list of fields that can be processed. User Response: Correct the recipe definition. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5202E | RV-ARRAYs are not supported | 
 
			  
				| Explanation: The Rendezvous array types are not supported. User Response: Correct the recipe definition. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5203E | RV-User types are not supported | 
 
			  
				| Explanation: The Rendezvous user types are not supported. User Response: Correct the recipe definition. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5205E | Receiving field has invalid length | 
 
			  
				| Explanation: The receiving field has an invalid length User Response: Correct recipe definition. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5206E | Numeric overflow | 
 
			  
				| Explanation: The receiving numeric field is too small for the input data. User Response: Correct the recipe definition or input data. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5207E | Input value is not numeric | 
 
			  
				| Explanation: The input value is not numeric. User Response: Correct the recipe definition or input data. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5208E | Input float value invalid | 
 
			  
				| Explanation: The value of a float field is invalid. User Response: Correct the recipe definition or input data. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5209E | Decimal adjust error | 
 
			  
				| Explanation: An error occurred during the adjustment of the placement of the decimal point. User Response: Correct the recipe definition or input data. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5210E | Input string too large to pack | 
 
			  
				| Explanation: An input string is too large to pack into a packed decimal field. User Response: Correct the recipe definition or input data. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5211E | Sending field too long | 
 
			  
				| Explanation: The sending field is too long. User Response: Correct the recipe definition or input data. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5212E | Sending length is not positive | 
 
			  
				| Explanation: The sending field is described by a nonpositive length. User Response: Correct the recipe definition or input data. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5213E | IPADDR32 string is invalid | 
 
			  
				| Explanation: The sending field is not in the proper IPADDR32 format. User Response: Correct the recipe definition or input data. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5214E | Unknown buffer field type | 
 
			  
				| Explanation: The buffer definition contains an unknown type field. User Response: Correct the recipe definition. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5215E | Output RV-MSG not supported | 
 
			  
				| Explanation: 
				  RV-MSG is not supported at the field level. User Response: Correct the recipe definition or input data. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5216E | Output ENCRYPT not supported | 
 
			  
				| Explanation: The Rendezvous type ENCRYPT is not supported. User Response: Correct the recipe definition. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5217E | Output NONE not supported | 
 
			  
				| Explanation: The Rendezvous type NONE is not supported. User Response: Correct the recipe definition. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5218E | Output XML not supported | 
 
			  
				| Explanation: The Rendezvous type 
				  XML is not supported. User Response: Correct the recipe definition. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5219E | Cannot convert [STRING | TEXT] to DATETIME | 
 
			  
				| Explanation: Conversion of 
				  STRING or 
				  TEXT to 
				  DATETIME failed. User Response: Correct the recipe definition. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5220E | Cannot convert PACK to IPADDR32 | 
 
			  
				| Explanation: Conversion of 
				  PACK to 
				  IPADDR32 has failed. User Response: Correct the recipe definition. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5221E | Cannot convert ZDEC to IPADDR32 | 
 
			  
				| Explanation: Conversion of 
				  ZDEC to 
				  IPADDR32 has failed. User Response: Correct the recipe definition. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5222E | Cannot convert FLOAT to IPADDR32 | 
 
			  
				| Explanation: Conversion of 
					 FLOAT to 
					 IPADDR32 has failed. 
				   User Response: Correct the recipe definition. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5223E | Cannot convert OPAQUE to DATETIME | 
 
			  
				| Explanation: Conversion of 
				  OPAQUE to 
				  DATETIME has failed. User Response: Correct the recipe definition. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5224E | Cannot convert OPAQUE to binaries | 
 
			  
				| Explanation: Conversion of 
				  OPAQUE to binary fields has failed. User Response: Correct the recipe definition. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5225E | Cannot convert OPAQUE to any float | 
 
			  
				| Explanation: Conversion of 
				  OPAQUE to floating point fields has failed. User Response: Correct the recipe definition. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5226E | Cannot convert OPAQUE to BOOL | 
 
			  
				| Explanation: Conversion of 
				  OPAQUE to 
				  BOOL has failed. User Response: Correct the recipe definition. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5227E | Cannot convert OPAQUE to IPPORT16 | 
 
			  
				| Explanation: Conversion of 
				  OPAQUE to 
				  IPPORT16 has failed. User Response: Correct the recipe definition. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5228E | Cannot convert OPAQUE to IPADDR32 | 
 
			  
				| Explanation: Conversion of 
				  OPAQUE to 
				  IPADDR32 has failed. User Response: Correct the recipe definition. 
				   System Action: The Input field is not processed. 
				   | 
 
			  
				| SXT5229E | Cannot convert UNSIGN-PACK to IPADDR32 | 
 
			  
				| Explanation: Conversion from Unsigned Packed to 
				  IPADDR32 is not supported. User Response: Correct the conversion rule. 
				   System Action: The conversion is marked as error. 
				   | 
 
			  
				| SXT5230E | Cannot convert UNSIGN-ZDEC to IPADDR32 | 
 
			  
				| Explanation: Conversion from Unsigned Packed to 
				  IPADDR32 is not supported. User Response: Correct the conversion rule. 
				   System Action: The conversion is marked as error. 
				   | 
 
			  
				| SXT5231E | OPAQUE cannot be zero length | 
 
			  
				| Explanation: The source field in the buffer resolved to a zero length, which is not supported in an 
				  OPAQUE field type. User Response: Correct the conversion rule or data. 
				   System Action: The conversion is marked as error. 
				   | 
 
			  
				| SXT5306E | Required and not found | 
 
			  
				| Explanation: The field is defined in the recipe as required but is not in the input message. User Response: Review the recipe definition. 
				   System Action: The remainder of the fields in the message are processed and then the message is rejected. 
				   | 
 
			  
				| SXT5309E | Required and not found | 
 
			  
				| Explanation: The field is defined in the recipe as required but is not in the input message. User Response: Review the recipe definition. 
				   System Action: The remainder of the fields in the message are processed and then the message is rejected. 
				   | 
 
			  
				| SXT5319E | Addfield failed | 
 
			  
				| Explanation: While constructing an output message, a messaging API call failed. User Response: Contact TIBCO Support with the information on the error from the log and trace files. 
				   System Action: The field is not added to message. 
				   | 
 
			  
				| SXT5324E | Field must be type RVMSG | 
 
			  
				| Explanation: The recipe step defines the field as 
				  RVMSG but the input message field is of some other type. User Response: Review the recipe definition. 
				   System Action: Processing of the message terminates. 
				   | 
 
			  
				| SXT5325E | SubMsg create failed | 
 
			  
				| Explanation: While processing an output message with embedded submessages, a call to API 
				  Func to create a submessage failed. Func: 
					 tibrvMsg_Create for Rendezvous message, 
					 tibemsMapMsg_Create, or 
					 tibemsStreamMsg_Create for EMS message 
				   User Response: Contact TIBCO Support with the information on the error from the log and trace files. 
				   System Action: Processing of the submessage terminates. 
				   | 
 
			  
				| SXT5328I | For CICS: U-Trc(RR) UoW:uow-number Task:task-number Idx:idx-number TID:Token-Id For IMS: U-Trc(RR) UoW:number TID:Token-Id 
				   | 
 
			  
				| Explanation: While processing an outbound back-end request/reply message, this message is produced if trigger trace level is 2 or greater.  
					 uow-number is the unit of work ID assigned to this message. 
					 task-number is the CICS task number generating the message. 
					 idx-number is the CICS request/reply slot being used. 
					 token-id is the value for tibss-envelope. 
					  User Response: Review the log for information on the request/reply process that might be of use for debugging. 
				   System Action: Processing continues. 
				   | 
 
			  
				| SXT5330E | Invalid Optional Special field | 
 
			  
				| Explanation: A special field defined in the recipe is not in the message. Though optional, that field is not a valid special field for input. User Response: Review the recipe definition. 
				   System Action: The remaining fields in the message are processed and then the message is rejected. 
				   | 
 
			  
				| SXT5333E | SubMsg AddMsg failed | 
 
			  
				| Explanation: While processing an output message with embedded sub-messages, a call to API Func for a sub-message failed. Func: 
					 tibrvMsg_AddMsg for Rendezvous message, 
					 tibemsMapMsg_SetMapMsg, 
					 tibemsMapMsg_SetStreamMsg, 
					 tibemsStreamMsg_WriteMapMsg, or 
					 tibemsStreamMsg_WriteStreamMsg functions for EMS message 
				   User Response: Contact TIBCO Support with the information on the error from the log and trace files. 
				   System Action: Processing of the submessage terminates. 
				   | 
 
			  
				| SXT5334W | SubMsg Destroy failed | 
 
			  
				| Explanation: While processing an output message with embedded submessages, the 
				  tibrvMsg_Destroy function for a submessage failed. User Response: Contact TIBCO Support. 
				   System Action: Processing continues. 
				   | 
 
			  
				| SXT5342E | Invalid Optional Special field | 
 
			  
				| Explanation: A Special field defined in the recipe is not in the message. Though optional, that field is not a valid special field for input. User Response: Review the recipe definition. 
				   System Action: The remaining fields in the message are processed and then the message is rejected. 
				   | 
 
			  
				| SXT5343E | Invalid Attributes | 
 
			  
				| Explanation: An input special field is not of the correct type or size. User Response: Review the recipe definition. 
				   System Action: The remaining fields in the message are processed and then the message is rejected. 
				   | 
 
			  
				| SXT5344E | Special Field not for Input | 
 
			  
				| Explanation: An input special field is not of the correct type or size. User Response: Review the recipe definition. 
				   System Action: The remaining fields in the message are processed and then the message is rejected. 
				   | 
 
			  
				| SXT5346E | Special Field not for Input | 
 
			  
				| Explanation: A special field that is defined in an input conversion cannot be an input field. User Response: Review the recipe definition. 
				   System Action: The remaining fields in the message are processed and then the message is rejected. 
				   | 
 
			  
				| SXT5347E | Add Envelope failed | 
 
			  
				| Explanation: While constructing an outbound message, the recipe requested the special field Envelope. 
				  Func failed. Func: 
					 tibrvMsg_AddOpaque for Rendezvous message, 
					 tibemsMapMsg_SetBytes, or 
					 tibemsStreamMsg_WriteBytes functions for EMS message 
				   User Response: Contact TIBCO Support with the information on the error from the log and trace files. 
				   System Action: The field is not added to the message. 
				   | 
 
			  
				| SXT5348E | Add config id failed | 
 
			  
				| Explanation: While constructing an outbound message, the recipe requested the special field config ID. 
				  Func failed. Func: 
					 tibrvMsg_AddString for Rendezvous message, 
					 tibemsMapMsg_SetString, or 
					 tibemsStreamMsg_WriteString functions for EMS message 
				   User Response: Contact TIBCO Support with the information on the error from the log and trace files. 
				   System Action: The field is not added to the message. 
				   | 
 
			  
				| SXT5349E | Add SS-id failed | 
 
			  
				| Explanation: While constructing an outbound message, the recipe requested the special field SS-id. 
				  Func failed. Func: 
					 tibrvMsg_AddString for Rendezvous message, 
					 tibemsMapMsg_SetString, or 
					 tibemsStreamMsg_WriteString functions for EMS message 
				   User Response: Contact TIBCO Support with the information on the error from the log and trace files. 
				   System Action: The field is not added to the message. 
				   | 
 
			  
				| SXT5350E | Spec Fld not for output | 
 
			  
				| Explanation: While constructing an outbound message, the recipe requested a Special field that cannot be used for output. User Response: Review the recipe or trigger definition. 
				   System Action: The field is not added to the message. 
				   | 
 
			  
				| SXT5351E | Add Envelope by bit failed | 
 
			  
				| Explanation: While constructing an outbound message, a bit setting requested the special field Envelope. 
				  Func failed. Func: 
					 tibrvMsg_AddOpaque for Rendezvous message, 
					 tibemsMapMsg_SetBytes, or 
					 tibemsStreamMsg_WriteBytes functions for EMS message 
				   User Response: Contact TIBCO Support with the information on the error from the log and trace files. 
				   System Action: The field is not added to the message. 
				   | 
 
			  
				| SXT5365E | F-Name Input Bytes size 
				  size greater than buffer 
				  bufsize | 
 
			  
				| Explanation: In an EMS Bytes message, the data included is larger than the receiving buffer. 
				   User Response: Correct the recipe or input message. 
				   System Response: Transaction is rejected with an error message. 
				   | 
 
			  
				| SXT5406E | No destination for output | 
 
			  
				| Explanation: While sending a response message, the reply failed and no response subject was specified. User Response: Specify one or more output destinations. 
				   System Action: This error is added to the error submessage. The entire response message is sent to the error subject, if specified. 
				   | 
 
			  
				| SXT5414E | Msg_Detach failed | 
 
			  
				| Explanation: The call to 
				  tibrvMsg_Detach has failed. User Response: Contact TIBCO Support. 
				   System Action: Processing of this message is terminated and responses are sent. 
				   | 
 
			  
				| SXT5416E | No thread specific info found | 
 
			  
				| Explanation: The call to 
				  pthread_getspecific has returned a 
				  null pointer. User Response: Contact TIBCO Support. 
				   System Action: Processing of this message is terminated and responses are sent. 
				   | 
 
			  
				| SXT5418E | No open entry in UOW list | 
 
			  
				| Explanation: No UOW entry is available to process with this message. User Response: Enlarge the UOW list or slow the pace of input. 
				   System Action: Processing of this message is terminated and responses are sent. 
				   | 
 
			  
				| SXT5423E | Failure in UOW Storage request | 
 
			  
				| Explanation: No user area is available to service this message. User Response: Contact TIBCO Support. 
				   System Action: Processing of this message is terminated and responses are sent. 
				   | 
 
			  
				| SXT5431E | Backend interface: 
				  Applid not responding Rsn: 
				  RSN | 
 
			  
				| Explanation: The nonzero return code 
				  RSN is sent to 
				  QandDispatch_Work. User Response: Contact TIBCO Support. 
				   System Action: Processing of this message is terminated and responses are sent. 
				   | 
 
			  
				| SXT5445E | BES data size less than required CFGID data size | 
 
			  
				| Explanation: During the processing of a trigger, the user data area in the COMMAREA was found to be smaller than the buffer size defined in the configuration file. User Response: Adjust the buffer sizes in the configuration file and ensure that 
					 TRIG-MAXSIZE in the CICS Interface parameters file is large enough. 
				   System Action: Processing of this message is terminated and responses are sent. 
				   | 
 
			  
				| SXT5464E | BES RC 
				  RC rsn 
				  RSN Unknown failure | 
 
			  
				| Explanation: The back-end processor has returned code 
				  RC with reason code 
				  RSN. User Response: Review the definition of the back-end processor. 
				   System Action: Processing of this message is terminated and responses are sent. 
				   | 
 
			  
				| SXT5476E | Create Msg failed rc 
				  RC | 
 
			  
				| Explanation: While processing a trigger, the call to 
				  Func failed with return code 
				  RC. Func: 
					 tibrvMsg_Create for Rendezvous message or 
					 tibemsMapMsg_Create for EMS message 
				   User Response: Contact TIBCO Support with the information on the error from the log and trace files. 
				   System Action: Processing of the trigger’s definition terminates. 
				   | 
 
			  
				| SXT5480E | Create Msg failed rc 
				  RC | 
 
			  
				| Explanation: The call to 
				  Func failed with return code 
				  RC. Func: 
					 tibrvMsg_Create for Rendezvous message or 
					 tibemsMapMsg_Create for EMS message 
				   User Response: Contact TIBCO Support with the information on the error from the log and trace files. 
				   System Action: Processing of this message is terminated and responses are sent. 
				   |