HVT Trigger Transactions
The following table shows the command-line parameters for sample HVT tasks.
| Command | Description | 
|---|---|
| SXTF/SXT6 | Sends one message through HVT in IVP format. | 
| SXTF/SXT6,HELP-? | Lists all the keywords for the available commands. | 
| SXTF/SXT6,type(G|R|O|S),number_of_records | Sends multiple IVP trigger messages through HVT in type. The valid type values are G for Guaranteed, R for Reliable, O for Ordered, and S for Temporary Storage Trigger. | 
| SXTF/SXT6,type(G|R|O|S),number_of_records,data_length(1 - 4096000) | Sends multiple messages through HVT in 
				  type and 
				  data_length. The valid 
				  type values are 
				  G for Guaranteed, 
				  R for Reliable, 
				  O for Ordered, and 
				  S for Temporary Storage Trigger. The maximum data length for the TSQ Trigger is 32000. | 
| SXTF/SXT6,type(G|R|O|S),number_of_records,data_length(1 - 4096000),service_name | Sends multiple messages through HVT in 
				  type and 
				  data_length to 
				  service_name (the trigger identifier). The valid 
				  type values are 
				  G for Guaranteed, 
				  R for Reliable, 
				  O for Ordered, and 
				  S for Temporary Storage Trigger. The maximum data length for the TSQ Trigger is 32000. | 
| SXTF/SXT6,Type(G|R|O|S),number_of_records,data_length(1 - 4096000),service_name,CTN | Sends multiple messages through HVT in type and 
				  data_length to 
				  service_name (the trigger identifier), using 
				  CTN number of containers. The valid type values are G for Guaranteed, R for Reliable, O for Ordered, and S for Temporary Storage Trigger. The maximum data length for the TSQ Trigger is 32000. The valid range for CTN is 1 to 20. | 
| SXTF,Type(G|R|O|S),number_of_records,data_length(1 - 4096000),service_name,CTN, 
				  delay_in_seconds SXT6,Type(G|R|O|S),number_of_records,data_length(1 - 4096000),service_name,CTN, delay_in_seconds .01,#Tasks | Sends multiple messages through HVT in 
				  type and 
				  data_length to 
				  service_name (the trigger identifier), using 
				  CTN number of containers, and with a delay of 
				  delay in seconds between calls to 
				  SXCQWRIT or 
				  SXCQWTSQ. The valid 
				  type values are 
				  G for Guaranteed, 
				  R for Reliable, 
				  O for Ordered, and 
				  S for Temporary Storage Trigger. The maximum data length for the TSQ Trigger is 32000. The valid range for CTN is 1 to 20. | 
The messages sent are either the default IVP messages or, if data_length is specified, a record of length data_length filled with 1--------10--------20------.