Managing H2 Metadata

When the server accesses a data source, it needs to know how to interpret the data stored there. For each object the server will access, you create a synonym that describes its structure and the server mapping of the data types.

Creating Synonyms

 

Synonyms define unique names (or aliases) for each object that is accessible from the server. Synonyms are useful because they hide the underlying data source location and identity from client applications. They also provide support for extended metadata features of the server, such as virtual fields and additional security mechanisms.

Using synonyms allows an object to be moved or renamed while allowing client applications to continue functioning without modification. The only modification required is a redefinition of the synonym on the server. The result of creating a synonym is a Master File and an Access File, which represent the server metadata.

Create a Synonym

    Procedure
  1. From the WebFOCUS Reporting Server browser interface Application page, click Get Data.
  2. On the Configured Adapters section of the page, in Simple Mode, right-click an adapter and click Show Connections. Right-click a connection.

    Depending on the type of adapter you choose, one of the following options appears on the context menu.

    • Show DBMS objects. This option opens the page for selecting synonym objects and properties.
    • Create metadata objects. This option opens the page for selecting synonym objects and properties.
    • Show files. This option opens a file picker. After you choose a file of the correct type, the page for selecting synonym objects and properties opens.
    • Show local files. This option opens a file picker. After you choose a file of the correct type, the page for selecting synonym objects and properties opens.
    • Show topics. This option opens the page for selecting synonym objects and properties for topics within the environment.
  3. Enter values for the parameters required by the adapter as described in the chapter for your adapter.
  4. After entering the parameter values, click Add.

    This button may be labeled Next, Create Synonym, Create Base Synonyms, Create Cluster Synonym, or Update Base Synonyms.

    The synonym creation process for most adapters has been consolidated so that you can enter all necessary parameters on one page. However, for some adapters such as LDAP, continue clicking Next until you get to a page that has a Create Synonym button.

Result

The synonym is created and added under the specified application directory.

Note: When creating a synonym, if you select the Validate checkbox, where available, the server adjusts special characters and checks for reserved words. For more information, see Validation for Special Characters and Reserved Words.

Synonym Creation Parameters for H2

The following list describes the synonym creation parameters for which you can supply values.

Object Type

Restrict candidates for synonym creation based on the selected object type(s): Tables, Views, External SQL Scripts, and any other supported objects.

Choosing External SQL Scripts from the drop-down list enables you to represent an SQL Query as a synonym for read-only reporting. A Synonym candidate can be any file that contains one (and only one) valid SQL Query and does not contain end-of-statement delimiters (";" or "/") and comments.

Depending on the adapter, you can further restrict your search by choosing checkboxes for listed objects.

Owner/Schema

Selecting this option adds the Owner/Schema and Object Name parameters to the screen. Select an owner/schema from the drop-down list or type a string for filtering the selection, inserting the wildcard character (%) as needed at the beginning and/or end of the string. Then click Search. For example, enter: ABC% to select tables or views whose owner/schema begin with the letters ABC; %ABC to select tables or views whose owner/schema end with the letters ABC; %ABC% to select tables or views whose owner/schema contain the letters ABC at the beginning, middle, or end.

Object Name

Selecting this option adds the Owner/Schema and Object Name parameters to the screen. Type a string for filtering the object names, inserting the wildcard character (%) as needed at the beginning and/or end of the string. Then click Search. For example, enter: ABC% to select all objects whose names begin with the letters ABC; %ABC to select all whose names end with the letters ABC; %ABC% to select all whose names contain the letters ABC at the beginning, middle, or end.

Location of External SQL Scripts

 If you specify External SQL Scripts in the Object Type field, these additional fields are displayed.

The following standard naming conventions apply for UNIX, IBM i IFS, and z/OS HFS:

  • In the Base Location field, specify the physical directory location of the file that contains the SQL Query. You can type a directory name or click on the ellipsis. This opens the Select Base Location dialog.
  • In the Document Name field, enter the file name with or without wild card characters.
  • In the Document Extension field, enter the extension of the script files to filter the list of candidates.

On IBM i, you can use alternative IFS naming conventions to access library members. The following entry illustrates this method:

  • In the Base Location field, enter:
    /QSYS.LIB/MYLIBRARY.LIB/MYSRC.FILE
  • The Document Extension is understood to be MBR. You can enter this value explicitly or leave the input box blank.

During synonym generation, the adapter issues native API calls to obtain a list of elements in the select list and builds the Master File with a field for each element. The generated Access File references the location of the SQL script in the DATASET attribute, which contains the full path, including the name and extension of the file containing the SQL Query. For example,

DATASET=/ul/home2/apps/report3.sql

When a WebFOCUS report is created, the SQL Query is used to access data.

Row Limit

Select the number of objects to display on the Create Synonym page.

For Subquery

Only available when External SQL Scripts is selected from the object type drop-down menu. When selected, a SUBQUERY keyword is added to the Access File of the generated synonym. If the corresponding SQL string has valid syntax that can be used in the FROM statement of the generated SQL (what is known as a Derived Table), then the SQL SCRIPT will be processed as a subquery embedded into a FROM clause. This usage allows for more flexibility. For example, the synonym can be used as a target for a JOIN.

If the SQL SCRIPT has parameter markers, such as ? or :, or the syntax contains constructs that are invalid for a derived table, for example ORDER BY, then this keyword should not be selected. At runtime, if SUBQUERY=Y is present and it is determined that the SQL SCRIPT cannot be used in the FROM statement, the setting will be ignored, and a FOC1782 warning message will be issued. The default is selected (SUBQUERY=Y).

Application

Select an application directory. The default value is baseapp.

Prefix/Suffix

If you have tables with identical table names, assign a prefix or a suffix to distinguish them. For example, if you have identically named human resources and payroll tables, assign the prefix HR to distinguish the synonyms for the human resources tables. Note that the resulting synonym name cannot exceed 64 characters.

If all tables and views have unique names, leave the prefix and suffix fields blank.

Customize data type mappings

To change the data type mappings from their default settings, select this checkbox. The customizable mappings are displayed.

For information about customizable mappings, see Access File.

Create: Cluster Synonym or Base Synonyms

Select the button for the type of synonym you want to create.

Default Synonym Name

This column displays the name that will be assigned to each synonym. To assign a different name, replace the displayed value.

Owner/Schema

The user account that created the object or a collection of objects owned by a user.

Fact or Dimension

You can check Fact or Dimension to generate the segment as a fact table or a dimension segment. If you are creating a cluster synonym, you can right-click a selected fact table and select Show Related Dimensions or Add Related Dimensions to show a list of related dimensions or add related dimensions to the synonym.

Table name

Is the name of the underlying object.

Type

The object type (Table, View, and so on).

Select tables

Select tables for which you wish to create synonyms:

  • When creating base synonyms, you can select all tables in the list by clicking the Select All checkbox.
  • To select specific tables, select the corresponding checkboxes.

Once you have selected the objects for which you want to create synonyms, click the Create Base Synonyms or Create Cluster Synonym button on the ribbon.

Sample Generated Synonym

An Adapter for H2 synonym comprises a Master File and an Access File. This is a synonym for the table nf29104.

Master File nf29104.mas

FILENAME=NF29104, SUFFIX=SQLH2D  , $
  SEGMENT=NF29104, SEGTYPE=S0, $
    FIELDNAME=DIVISION4, ALIAS=division4, USAGE=I11, ACTUAL=I4,
      MISSING=ON, $
    FIELDNAME=DIVISION_NA4, ALIAS=division_na4, USAGE=A25V, ACTUAL=A25V,
      MISSING=ON, $
    FIELDNAME=DIVISION_HE4, ALIAS=division_he4, USAGE=I11, ACTUAL=I4,
      MISSING=ON, $

Access File nf29104.acx

SEGNAME=NF29104, 
   TABLENAME="r729999d"."nf29104", 
   CONNECTION=CON1, $

Access File Keywords

This chart describes the keywords in the Access File.

Keyword

Description

SEGNAME

Value must be identical to the SEGNAME value in the Master File.

TABLENAME

Identifies the H2 table. The value assigned to this attribute can include the name of the owner (also known as schema) and the database link name as follows:

TABLENAME=[owner.]table
CONNECTION

Indicates a previously declared connection. The syntax is:

CONNECTION=connection

CONNECTION=' ' indicates access to the local data source.

Absence of the CONNECTION attribute indicates access to the default database server.

KEYS

Indicates how many columns constitute the primary key for the table. Corresponds to the first n fields in the Master File segment.

See the KEY attribute below for information about specifying the key fields without having to describe them first in the Master File.

KEY

Specifies the columns that participate in the primary key without having to describe them as the first fields in the Master File. The syntax is:

KEY=fld1/fld2/.../fldn
WRITE

Specifies whether write operations are allowed against the table.

KEYFLD
IXFLD

Supply the names of the primary key and foreign key fields that implement the relationships established by the multi-table Master File. Together, KEYFLD and IXFLD identify the field shared by a related table pair.

  • KEYFLD is the FIELDNAME of the common column from the parent table.
  • IXFLD is the FIELDNAME of the common column from the related table.

KEYFLD and IXFLD must have the same data type. It is recommended, but not required, that their lengths also be the same.

Note: An RDBMS index on both the KEYFLD and IXFLD columns provides the RDBMS with a greater opportunity to produce efficient joins. The columns must have the same data type. If their length is the same, the RDBMS handles the join more efficiently.

Managing Synonyms

Once you have created a synonym, you can right-click the synonym name in the navigation pane of either the WebFOCUS Reporting Server browser interface or ibi Data Migrator desktop interface to access the available options.

For a list of options, see Synonym Management Options.

Data Type Support Report

SQL Data Type mapping options are available in a report available from the WebFOCUS Reporting Server browser interface.

For more information, see Access the Data Type Report.

Changing the Precision and Scale of Numeric Columns

You can alter the length and scale of numeric columns returned by a SELECT request to the server by creating different specifications in your login profile or in a stored procedure. The conversion settings are reflected in the Master File in the USAGE and ACTUAL formats of the fields generated by CREATE SYNONYM. This affects how the fields are processed and formatted by the server.

Tip: You can change this setting manually or from the WebFOCUS Reporting Server browser interface.

For more information, see Override the Default Precision and Scale.