Configuring the Adapter for Teradata
Configuring the adapter consists of specifying connection and authentication information for each of the connections you want to establish.
Declaring Connection Attributes
In order to connect to a Teradata database server, the adapter requires connection and authentication information. You supply this information using the SET CONNECTION_ATTRIBUTES command. You can:
- Enter connection and authentication information in the WebFOCUS Reporting Server browser interface or ibi Data Migrator desktop interface configuration panes. The consoles add the command to the profile you select: the global server profile (edasprof.prf), a user profile (user.prf), or a group profile (if supported on your platform).
- Manually add the command in the global server profile (edasprof.prf), in a user profile (user.prf), or in a group profile (if supported on your platform).
You can declare connections to more than one Teradata database server by including multiple SET CONNECTION_ATTRIBUTES commands. The actual connection to the Teradata Server takes place when the first query that references the connection is issued. If you issue multiple SET CONNECTION_ATTRIBUTES commands:
- The connection named in the first SET CONNECTION_ATTRIBUTES command serves as the default connection.
- If more than one SET CONNECTION_ATTRIBUTES command contains the same connection name, the adapter uses the attributes specified in the last SET CONNECTION_ATTRIBUTES command.
Configuring an Adapter
- Procedure
- From the WebFOCUS Reporting Server browser interface Applications page, click Get Data.
- In the WebFOCUS Reporting Server browser interface, click the (+) button, and find the adapter on the page or, in the ibi Data Migrator desktop interface, exapnd the Available folder if it is not already expanded.
- In the ibi Data Migrator desktop interface, expand the appropriate group folder and the specific adapter folder. The group folder is described in the connection attributes reference.
- Right-click
the adapter name and/or version and select
Configure.
The Add Adapter to Configuration pane opens.
- Enter values for the parameters required by the adapter, as described in the chapter for the specific adapter you want to configure.
- Click
Configure. The configured adapter is added to the
Configured list in the
WebFOCUS Reporting Server browser interface or in the Adapters
list in the ibi Data Migrator desktop interface resources tree.
In the WebFOCUS Reporting Server browser interface, the adapter remains on the Available Adapters list with an asterisk to indicate that at least one connection has been configured. You can configure additional connections from either the Configured or Available list by right-clicking the adapter and clicking Add Connection.
Connection Attributes for Teradata
The Teradata adapter is under the SQL group folder.
The following list describes the connection attributes for which you can supply values. To complete the attribute declaration, click the Configure button.
Note that the release numbers on the WebFOCUS Reporting Server browser interface for DBMS Add and DBMS Change panes refer to the Teradata ODBC driver, not the Teradata DBMS release.
This is the logical name used to identify this particular set of connection attributes.
Valid Teradata data source name (DSN). There is no default DSN; you must enter a value.
For the ODBC interface, this DSN name should match the User, System, or File DSN configured in the ODBC Administrator on Windows or the DSN entry in the $HOME/.odbc.ini file on UNIX.
For the CLI interface, this field is labeled SERVER and requires a valid Teradata TDP value. On Windows and UNIX, this is the value of i_dbcpath in the clispb.dat file. The default is DBC or <default>. This value may also be derived from the host file entry for the TD server. For example, if the host file contains td13cop1, then the server value will be td13. Refer to the Teradata Tools and Utilities documentation for details.
There are two methods by which a user can be authenticated when connecting to a database server:
- Explicit. The user ID and password are explicitly specified for each connection and passed to the database, at connection time, for authentication.
- Password Passthru. The user ID and password received from the client application are passed to the database, at connection time, for authentication.
Primary authorization ID by which you are known to the data source.
Password associated with the primary authorization ID.
Select a profile from the drop-down menu to indicate the level of profile in which to store the CONNECTION_ATTRIBUTES command. The global profile, edasprof.prf, is the default.
If you wish to create a new profile, either a user profile (user.prf) or a group profile if available on your platform (using the appropriate naming convention), choose New Profile from the drop-down menu and enter a name in the Profile Name field (the extension is added automatically).
Store the connection attributes in the server profile (edasprof).
Declare Connection Attributes Manually
ENGINE SQLDBC SET CONNECTION_ATTRIBUTES {connection DSN_name|Server}
/userid,password
where:
Indicates the adapter. You can omit this value if you previously issued the SET SQLENGINE command.
This is the logical name used to identify this particular set of connection attributes.
Note that one blank space is required between connection and DSN_name.
For the Adapter for Teradata ODBC, this is the Teradata Data Source Name (DSN) you wish to access. It must match an entry in the odbc.ini file.
For the Adapter for Teradata CLI, this is the Teradata Director Program number (TDPn), where n is the number. This is the value of i_dbcpath in the clispb.dat file.
Is the primary authorization ID by which you are known to Teradata.
Is the password associated with the primary authorization ID.
Declaring Connection Attributes
The following SET CONNECTION_ATTRIBUTES command connects to the Teradata database server named SAMPLESERVER with an explicit user ID (MYUSER) and password (PASS). To ensure security, specify connection attributes from the WebFOCUS Reporting Server browser interface, which encrypts the password before adding it to the server profile.
ENGINE SQLDBC SET CONNECTION_ATTRIBUTES CON1 SAMPLESERVER/MYUSER,PASS
Updating the Connection String for Teradata
The syntax for the CONNECTION_ATTRIBUTES command for this adapter has been enhanced to include a logical connection name that is designed to support the porting of applications from development to production environments. This enhanced syntax may necessitate the migration of existing CONNECTION_ATTRIBUTES commands.
The WebFOCUS Reporting Server browser interface Migrate option migrates your server settings to the newer release. To access this option, select Workspacefrom the Toolsmenu.SelectMigrate fromSettings. On the Migrate pane, type the full path of the configuration instance directory (EDACONF) and click the Continue button. This is the recommended approach.
If you choose not to use the Migrate option, please note the following information:
- Connection names declared.
- If you create a new connection for the purpose of creating new synonyms, your existing connections are re-saved in a new format, and the existing synonyms continue to work without any changes.
- If you add a new connection for the purpose of using an existing
synonym, you must change the default logical connection name to
match the value that is stored in the existing Access File attribute
CONNECTION=value.
For example, suppose that prior 7.6.1 the connection was defined as:
ENGINE SQLDBC SET CONNECTION_ATTRIBUTES DSN_A/uid,pwdWhen synonyms based on objects stored in this DSN_A are created, the Access Files contains the following description:
CONNECTION=DSN_A
If you then add a new connection, you must change the connection name from the default CON01 to DSN_A and save it as DSN_A in order to reuse the existing synonym. The connection is stored in the profile as:
ENGINE SQLDBC SET CONNECTION_ATTRIBUTES DSN_A DSN_A/uid,pwd
Overriding the Default Connection
Once connections have been defined, the connection named in the first SET CONNECTION_ATTRIBUTES command serves as the default connection. You can override this default using the SET DEFAULT_CONNECTION command.
Change the Default Connection
ENGINE SQLDBC SET DEFAULT_CONNECTION connection
where:
Indicates the adapter. You can omit this value if you previously issued the SET SQLENGINE command.
Is the connection defined in a previously issued SET CONNECTION_ATTRIBUTES command. If this name was not previously declared, the following message is issued:
FOC1671, Command out of sequence
- If you use the SET DEFAULT_CONNECTION command more than once, the connection name specified in the last command serves as the default connection.
- The SET DEFAULT_CONNECTION command cannot
be issued while an uncommitted transaction (LUW) is pending. In
that case, the following message is issued:
FOC1671, Command out of sequence.
Selecting the Default Connection
The following SET DEFAULT_CONNECTION command selects the database server named SAMPLE as the default database server:
ENGINE SQLDBC SET DEFAULT_CONNECTION SAMPLE
Controlling the Connection Scope
The SET AUTODISCONNECT command controls the persistence of connections when using the adapter for each of the connections you want to establish.
Control the Connection Scope
ENGINE SQLDBC SET AUTODISCONNECT ON {FIN|COMMAND|COMMIT}
where:
Indicates the adapter. You can omit this value if you previously issued the SET SQLENGINE command.
Disconnects automatically only after the session has been terminated. FIN is the default value.
Disconnects automatically after each request. Depending on how often the event occurs, the SET AUTODISCONNECT command may result in considerable overhead. Almost all of this overhead is not related to the server. It is related to the operating system and the data source.
Disconnects automatically only after COMMIT or ROLLBACK is issued as a native SQL command.