Configuring haltOnError
haltOnError is enabled on a new installation of the BPM runtime. Its setting is unchanged when the BPM runtime is upgraded.
To configure haltOnError, modify the value of the haltOnError property in the bx.properties file. For more information, see Process Instance Properties (bx.properties).
haltOnError can also be configured on a per-process or per-activity basis. For more information about how to do this, see the description of the System Error Action and BPM Task Retry properties in the TIBCO Business Studio Modeling User’s Guide.