Contents
The Spotfire Streaming Binary File Reader is an embedded input adapter that reads structured binary files created with the Spotfire Streaming Binary File Writer Output Adapter. It is not a general purpose tool to read arbitrary binary files.
In general, you will use the Binary File Writer and Binary File Reader as an adapter pair to write a stream of tuples to a file, then read them back from that file at a different point in your application. The Binary File Reader and Writer adapters are much like the CSV File Reader and Writer adapter pair, except that reading and writing binary files is significantly faster than reading and writing text files in CSV format. You might use the Binary File Writer and Reader as part of a High Availability scenario to preserve the contents of a tuple stream to disk. As part of a failover event, the secondary server in a StreamBase Server cluster could restore the contents of a stream with a fast read of the saved file.
If the Binary File Writer wrote its output file with its Compress data option enabled (which writes the output file in gzip
format with .gz
extension), then the Binary File Reader
adapter automatically uncompresses the file when reading it.
By default, an instance of the Binary File Reader adapter has a single output port. In this case, the name of the file to process is designated in the File Name setting, and the adapter begins processing that file as soon as it starts.
You can add one or more of the following optional ports:
-
An Error Output Port, which outputs a StreamBase error tuple for any adapter error.
-
A Control Input Port, which accepts a tuple containing the name of an input file to process.
-
A Event Output Port, which outputs a tuple every time an input file is opened or closed.
The optional ports are further described in the next section.
The Binary File Reader Adapter has the following properties on the General tab in its Properties View in StreamBase Studio:
Name: Use this required field to specify or change the name of this instance of this component. The name must be unique within the current EventFlow module. The name can contain alphanumeric characters, underscores, and escaped special characters. Special characters can be escaped as described in Identifier Naming Rules. The first character must be alphabetic or an underscore.
Adapter: A read-only field that shows the formal name of the adapter.
Class name: Shows the fully qualified class name that implements the functionality of this adapter. If you need to reference this class name elsewhere in your application, you can right-click this field and select Copy from the context menu to place the full class name in the system clipboard.
Start options: This field provides a link to the Cluster Aware tab, where you configure the conditions under which this adapter starts.
Enable Error Output Port: Select this checkbox to add an Error Port to this component. In the EventFlow canvas, the Error Port shows as a red output port, always the last port for the component. See Using Error Ports to learn about Error Ports.
Description: Optionally, enter text to briefly describe the purpose and function of the component. In the EventFlow Editor canvas, you can see the description by pressing Ctrl while the component's tooltip is displayed.
The Binary File Reader Adapter has the following properties on the Adapter Settings tab in its Properties View in StreamBase Studio:
Property | Data Type | Description |
---|---|---|
File Name | string |
Specify the name of a binary input file to read. The file must have been
created by the Binary File Writer Adapter. This Reader adapter
automatically determines whether the file was created with the compression
option when using the Writer adapter.
As an alternative to hard-coding an input file name, you can use the Start Control Port setting described below. |
Read As Resource | checkbox | If enabled and the path given is not absolute then the file will be resolved as a resource file |
Capture Transform Strategy | radio button | The strategy to use when transforming capture fields for this operator. The FLATTEN strategy expands capture fields at the same level as non-captured fields. FLATTEN is the default and is usually sufficient. The NEST strategy expands captured fields by encapsulating them as type Tuple. Use NEST to avoid duplication of field names, at the cost of a more complex schema. |
Period | int | The time, in milliseconds, to wait between processing each record. If 0, the adapter reads the file one record after another without pausing. Use this setting to slow down processing of the input file. |
Start Control Port | check box | If selected, this setting adds an input port to the adapter instance. The input port is a control port that accepts a schema with a single field of string type. Your application can send a tuple to this control port containing the name of a binary file to read. In this case, the adapter waits for a tuple to arrive at the input control port before it begins reading any files. You can send a sequence of file names to the control port, for each to be processed by the adapter in turn. |
Start Event Port | check box | If selected, this setting adds an event output port to the adapter instance. The event port outputs a tuple for each file open and file close event in the adapter. That is, an event tuple is sent every time an input file is opened or closed. |
Log Level | INFO | Controls the level of verbosity the adapter uses to issue informational traces to the console. This setting is independent of the containing application's overall log level. Available values, in increasing order of verbosity, are: OFF, ERROR, WARN, INFO, DEBUG, TRACE. |
Use the Edit Schema tab to specify the schema of the output tuple for this adapter. For general instructions on using the Edit Schema tab, see the Properties: Edit Schema Tab section of the Defining Input Streams page.
Use the settings in this tab to enable this operator or adapter for runtime start and stop conditions in a multi-node cluster. During initial development of the fragment that contains this operator or adapter, and for maximum compatibility with releases before 10.5.0, leave the Cluster start policy control in its default setting, Start with module.
Cluster awareness is an advanced topic that requires an understanding of StreamBase Runtime architecture features, including clusters, quorums, availability zones, and partitions. See Cluster Awareness Tab Settings on the Using Cluster Awareness page for instructions on configuring this tab.
Use the Concurrency tab to specify parallel regions for this instance of this component, or multiplicity options, or both. The Concurrency tab settings are described in Concurrency Options, and dispatch styles are described in Dispatch Styles.
Caution
Concurrency settings are not suitable for every application, and using these settings requires a thorough analysis of your application. For details, see Execution Order and Concurrency, which includes important guidelines for using the concurrency options.
Typechecking fails if the schema does not have at least one parameter. The File Name field fails to typecheck only if it is blank and you have not enabled the Start Control Port option.
On suspend, the Binary File Reader will finish processing the current record, output the tuple, and then pause. The input file will remain open and the adapter will retain its position in the file. It will stay paused until it is either shut down or resumed.
When it resumes, the Binary File Reader continues processing with the next record in the input file.