Configuring Fault Tolerant Behavior
For fault tolerant configurations, specify peer appliance information.
Prompt | Description |
---|---|
Is this in a Fault-Tolerant pair (yes): | Hit enter if this appliance is connected to a second Appliance as part of a fault-tolerant pair.
If this appliance is intended to run as a single installation, type no and hit enter and proceed to Beginning Appliance Operations. |
Primary Instance (0 or 1) on local EMS Server (): | Enter
0 if the primary TIBCO Enterprise Message Service™ server instance on this appliance should be identified as instance
0.
Enter 1 if the primary EMS server instance should be instance 1. Both appliances in a fault tolerant pair may not use the same instance number to identify their primary EMS servers. One appliance must be configured to have its primary server be instance 0 and the other must have its primary server be instance 1. |
EMS Server Instance Name of the other host of the FT pair (): | Enter the EMS Instance Name used to identify the EMS server instance on the second appliance in the fault tolerant pair. This name is set in
Configuring EMS Server Information.
For example inst1. |
EMS Server IP of the other host of the FT pair (): | Enter the EMS server IP address for the other appliance in the fault tolerant pair.
This address is used to configure the secondary listen URL for the secondary EMS server instance. |
EMS Server Port of the other host of the FT pair (): | Enter the port number of the fault tolerant peer appliance's primary EMS server instance. |
Copyright © Cloud Software Group, Inc. All rights reserved.