Contents
Before you install TIBCO StreamBase® software:
-
Read this Release Notes document.
-
Confirm that your target system matches the hardware and software requirements discussed on Supported Configurations.
-
Read the Installation Guide.
-
For a summary of what's new in this release, see New and Noteworthy.
-
If you are new to StreamBase, read Getting Started after installation.
-
See the documentation home page to begin exploring the StreamBase documentation. The StreamBase documentation set is available as part of your StreamBase installation in several ways:
-
In TIBCO StreamBase® Studio, select
→ from the menu. This is the best option, and provides a searchable help system. -
On Windows, open
→ → → → -
From the installed file system, open the documentation home page in a web browser. The default locations are:
Linux and Solaris /opt/tibco/sb-cep/
n.m
/doc/index.html Windows C:\TIBCO\sb-cep\n.m
\doc\index.html Macintosh OS X {customer-specific-folder}/TIBCO StreamBasen.m.x
/doc/index.htmlTo open the documentation directly to the TIBCO LIve Datamart sections, open the file
lvindex.html
instead. -
If you were provided an installation DVD-ROM or disk image, open
doc/index.html
ordoc/lvindex.html
in a web browser.
-
Contact Information contains information about available support options. You can send us e-mail or get information from your TIBCO representative about our support portal.
The following sections provides lists of errors corrected and features updated in each maintenance release of TIBCO StreamBase, in descending release order.
Fixed in 7.6.7 | |
---|---|
Number | Resolution |
TIBCO StreamBase® 7.6.7 incorporates all fixes resolved in the release 7.5 series through 7.5.6. | |
SB‑30500 | The Web Reader input adapter can now output a tuple with all null values when reading in line by line mode, to signify completion. |
SB‑30476 | Typechecking was updated for the MQTT Client Publish and Subscribe adapters to fix issue involving an invalid URI check failure. |
SB‑30401 | An issue prevented some sbconf files from maintaining module-search entries from referenced projects. Now, when a change to the module or resource search path is detected, Studio can run a sbconf synchronization update for all projects that refer to the current project. |
SB‑30376 | Previously, when an inner module's input stream and its outer module's input stream had a capture field with the same typename, a compilation error would occur. This was fixed. |
SB‑30375 | A CompileException Unknown variable error caused some applications to fail when run in debug mode. This was resolved. |
SB‑30255 | Prior to 7.6.7, the mechanism to deploy decision tables from an Artifact Management Server to StreamBase was incompatible with the Decision Table operator. The operator was modified in 7.6.7 to correct this incompatibility. |
SB‑30249, SB‑29197 | 7.6.7 fixes an issue in which importing a schema from XSD would not handle nested tuple fields correctly. |
SB‑30156 | The TERR operator can experience performance issues when invoked with large lists. 7.6.7 improves the operator's performance when in dynamic mode. Also, the output of any failing script will be added as an INFO log message when a script fails. |
SB‑30318 | The Kafka Publisher adapter experienced an issue where it would not send the tuple outputs asynchronously when in async mode, which could cause a deadlock in some cases. This was fixed. |
SB‑30302 | A project created in release 7.6.5 occasionally failed to typecheck, and returned an NPE in 7.6.6. This was fixed, and typechecking now returns a meaningful message instead of NPE. |
SB‑30007 | Naming a Query operator's group-by fields identical to any of its input fields used to cause errors. This was fixed. |
SB‑29990 | When loading a feed simulation file, an issue prevented the Feed Simulation Input Adapter to fail to stop or pause properly in some cases. This was fixed. |
SB‑29961, SB‑29962 |
Prior to 7.6.7, the the Kafka Consumer adapter was ignoring the buffer size,
fetch size, and timeout properties found on the Advanced tab. This was fixed.
Also, to prevent the adapter from failing to read messages, a WARN message is
now sent when the highWatermark value for the
requested topic or partition is higher than the requested offset value.
|
SB‑29953 | In cases where the FTL Publishing Output or the FTL Subscribing Input adapter's configured EndPoint does not exist on the FTL server, the adapter kept creating new clients. Eventually the adapter ran out of possible clients, blocking all new access. This was fixed. |
SB‑29904 | Prior to 7.6.7, moving or deleting a row from an .sbdt decision table would not renumber the remaining rows. For example, deleting rule 5 out of 10 would not renumber rules 6 to 10 to rules 5 to 9. This was fixed. Now, right-clicking the ID block in the Decision Table editor presents two options: Reorder All Rules By ID, and Reset All Rule IDs. |
SB‑29897 | A memory leak issue hindered the FTL Map Set Operator's performance. This was fixed. |
SB‑29844 | The LiveView Query adapter would fail on occasion if the input contained a Capture field. Capture fields now work properly when used in the input schema for the LiveView Query adapter. |
SB‑29719, SB‑29539 | Setting a decision table version number in StreamBase Studio prevented the Artifact Management Server's API from retrieving those version numbers. The version field was removed from the StreamBase Decision Table editor. For backward compatibility, opening existing decision tables written with older versions of the Decision Table editor or with the Microsoft Excel add-in that contain a version number is still supported. |
SB‑29296 | The Decision Table Analyzer's Date and Time picker was improved to address numerous usability issues. |
SB‑29189 | An issue was fixed where the JMS configuration editor would erroneously report classpath warnings when running the Test Connection operation. |
SB‑29079 | The Decision Table editor in Studio failed to retain list types for any element, when creating StreamBase decision tables in .sbdt format. A List Type check box was added to the Add Column dialog to enable list retention. |
SB‑29056 | An issue prevented entering timestamps into a running Decision Table EventFlow module when using the Manual Input view. This was fixed to allow timestamp entry in the following format: YYYY-MM-DD hh-mm-ss. |
Fixed in 7.6.6 | |
---|---|
Number | Resolution |
TIBCO StreamBase® 7.6.6 incorporated all fixes resolved in the release 7.5 series through 7.5.6. | |
SB‑29921 | The HDFS File Writer adapter caused an NPE when the default file name was selected and the serialize type was set to Avro. This was fixed. |
SB‑29890 | The Map Set operator for FTL was raising an error when the FTLLockMap field was not null. This was fixed. |
SB‑29817 | The Bi-Directional Socket Input/Output adapter, when set to server mode, attempted to connect back to any clients that had disconnected. This was corrected. |
SB‑29771 | An issue in the shutdown logic caused the UDP Receiver adapter to block sbd shutdown. This was resolved. |
SB‑29722 | The HDFS File Writer allows setting a user either in the Properties view or via the incoming tuple (which overrides the Properties value). When the serialize type was set to Parquet, the user field was not working properly and instead the current system user was used. This was fixed. |
SB‑29680 | And issue prevented the JMS Connect operator from outputting connected messages on the status port. The JMS Connect operator now always outputs a CONNECTED status message when the connection is successful. |
SB‑29661 | An issue caused the XML to Tuple operator to handle the BOM character at the start of a file incorrectly. BOM characters are now removed before performing XML operations. |
SB‑29599 | Prior to StreamBase version 7.6.6, the decision table operator could incur the following exception during the processing of an input tuple if one of its fields was of type tuple and had the same name as the named schema for that field: "Evaluation exception: Reference to multiply defined field in Decision Table operator." This was fixed. |
SB‑29590 | An NPE could occur on the Bloomberg B-Pipe adapter if Market List Snapshow or Reference Data option ports were disabled and their associated command was executed. This was fixed. Also, users will now receive a warning message in the logger, as well as a status port message. |
Fixed in 7.6.5 | |
---|---|
Number | Resolution |
TIBCO StreamBase® 7.6.5 incorporated all fixes resolved in the release 7.5 series through 7.5.6. | |
SB‑29595 | The response message from the Bloomberg B-Pipe Input adapter was not helpful in cases where a market list snapshot request failed. The adapter was updated to provide error log information in this case. |
SB‑29588 | The File Writer adapter was emitting an exception on startup if the control port was not enabled. This was corrected. |
SB‑29565 | The Kafka Admin adapter incorrectly rejected broker commands when the Topics port was disabled. This was fixed. |
SB‑29430 | Previously, the intersect() and has_intersection() functions only worked on list(string). This was corrected such that both functions now work on ANY list type, as documented, as long as the two lists in the argument list are of the same type. For example, if the first list is a list of string, the second must also be a list of string. |
SB‑29396 | Under certain conditions when streambase.codegen.allow-refactoring was set to true and when using applications that have very large schemas, the application would fail to compile with a JaninoRuntimeException. This was fixed. |
SB‑29206, SB‑29200 | Release 7.6.5 fixes a deadlock issue that could occur when making remote container connections between StreamBase servers. Remote container connections are implemented internally using StreamBase-to-StreamBase adapters and these were making synchronous connections. The deadlock was fixed by requiring the adapter to use an asynchronous connection. |
Fixed in 7.6.4 | |
---|---|
Number | Resolution |
TIBCO StreamBase® 7.6.4 incorporated all fixes resolved in the release 7.5 series through 7.5.6. | |
SB‑29243 | An issue prevented the copy, cut, and paste functionality from working in the Decision Table Editor. This was fixed. |
SB‑29233 | Release 7.6.4 fixes a problem in the JMS Configuration Editor that caused updates to the server connection type to be dropped occasionally when toggling between JNDI and Direct. |
SB‑29196 | An error in the HBase Scan Operator caused an NPE in cases where the schema did not include tuple top level items. Typecheck now correctly ensures that the user-defined schema must have only tuples at the top level. |
SB‑29195 | Previously, the Import proposed schemas hyperlink on the HBase Admin operator's Properties view was not importing sub-schemas properly. This was resolved, such that both the main and sub-schemas are now imported. |
SB‑29194 | An issue prevented the MQTT Client Publish adapter from copying the input tuple's binary data when set up to send data as a blob. This was corrected. |
SB‑29154 | The Kafka Producer adapter was not correctly handling custom serializer settings. This was fixed. |
SB‑29146 | The XML to Tuple and Tuple to XML operators were failing to process tuples containing capture fields. The XML operators now work correctly when using passthrough fields that contain capture fields. |
SB‑29115 | Previously, an issue caused the FIX adapter, and all adapters inherited from the FIX adapter, to pass duplicate tags. This was fixed. |
SB‑29109 | The Bidirectional Socket adapters were providing inaccurate typecheck error messages when running Custom Data Transformer applications. The adapters were updated to provide more informative error messages during typecheck. |
Fixed in 7.6.3 | |
---|---|
Number | Resolution |
TIBCO StreamBase® 7.6.3 incorporated all fixes resolved in the release 7.5 series through 7.5.5. | |
SB‑29129 | A problem was fixed in the EventFlow Debugger where, at a breakpoint, Query Tables listed in the <Tables> node of the Variables view could not be toggled open if any of the Query Tables had a large number of rows. The toggle triangles before the names of such tables were missing. With this fix, all Query Tables can be toggled open, regardless of the number of rows in the tables. |
SB‑29039 | Previously, passing literal nulls as an argument to Java functions caused an NPE. This was fixed, such that a typecheck error now occurs instead. |
SB‑29807 | When using the StreamBase JUnit feature, code generated to run the test was not correctly escaping quotes in JSON strings. This was fixed. |
SB‑29008 | The CSV Reader adapter could go into an infinite read loop when reading CSV files that had invalid lines at the end of the file. This was resolved. |
SB‑28980 | In previous releases, an error caused the Trading Component Framework's handler for DB Rapid Market to order the depth of book prices incorrectly. This was corrected. |
SB‑28894 | The ActiveSpaces Listen operator has an input stream schema with a required field, listenerID. Previous releases failed to document this field, even though it is shown being used in the ActiveSpaces sample. As of this release, this field is now documented both in the ActiveSpaces operator's page and in comments in the sample. |
SB‑28822 | The CSV Writer adapter was not correctly passing the input control tuple to the event port. This was resolved. |
SB‑28777 | The Web Reader adapter did not properly handle the 404 error code. This was fixed. |
SB‑26899 | In previous releases, the Vertica Load adapter was not correctly included with Mac OS X installations of StreamBase. This was corrected. |
SB‑25630 |
In previous releases, included sbconf files
containing sections that required merging with upper-level sbconf sections did not have their enciphered values
deciphered. This was fixed.
|
Fixed in 7.6.2 | |
---|---|
Number | Resolution |
TIBCO StreamBase® 7.6.2 incorporated all fixes resolved in the release 7.5 series through 7.5.5, and the release 7.4 series through 7.4.5. | |
SB‑28723 | The TERR Operator was updated to automatically insert quotes around strings used as timestamps. |
SB‑28715 | Previously, instances of one of the bidirectional socket adapters in client mode experienced issues reconnecting to StreamBase Server. Starting with this release, the bidirectional socket now tries to automatically reconnect on failure. If you send a disconnect command, the retry does not occur. This fix affects all adapters with Bidirectional Socket in their names. |
SB‑28699 | In earlier releases of the .NET operator, an error caused garbled characters to appear when StreamBase received a string of encoded byte data. The cause was detected and resolved. |
SB‑28694 | In previous releases, the UDP adapter packet size was set to 5K bytes. In release 7.6.2, an option was added to allow the UDP receiver to set the packet size. |
SB‑28677 | In previous releases, the CSV Socket Reader adapter would generate an error if the String Quote Character property was not set. This was fixed. |
Fixed in 7.6.1 | |
---|---|
Number | Resolution |
TIBCO StreamBase® 7.6.1 incorporated all fixes resolved in the release 7.5 series through 7.5.5, and the release 7.4 series through 7.4.5. | |
SB‑28692 | In release 7.6.0, a build error prevented the standalone StreamBase Manager program from launching on 64-bit Windows. This cause was detected and resolved. |
SB‑28683 | In release 7.6.0, a build error prevented the .NET operator sample, and certain other .NET related features, from running correctly. This issue was resolved. |
SB‑28658 | In release 7.6.0, a required third parameter was added to the control port for the StreamBase Feed Simulation adapter, but this caused problems for certain LiveView-related programs that were not expecting the parameter. As of 7.6.1, this adapter now has an optional File Name Field property that is disabled by default. |
SB‑28646 |
In previous releases, you could pass an empty value in a module parameter in
outer modules by using two quotes ("" ), and this
empty value was successfully passed to inner modules. Recent 7.4.x releases
changed this behavior. As of release 7.6.1, empty parameters in outer modules
were once again successfully passed to inner modules.
|
SB‑28593 | In previous releases, the percentile() function in the StreamBase expression language was restricted to having a fixed maximum number of tuples. This could cause obscure IndexOutOfBoundException errors when the containing Aggregate operator handled more than 10,000 tuples. This was corrected, such that the maximum is now calculated as a percentage of the available JVM memory, as long as the maximum number of bytes used by one Aggregate operator does not exceed integer.MAX_VALUE, or 2,147,483,647. |
SB‑28545 | In previous releases, the StreamBase Feed Simulation adapter could exit in a Null Pointer Exception error if the feed simulation's schema included a list. This was corrected. |
SB‑28529 | The Web Server Request adapter, when configured to handle web socket requests, was updated to produce the actual URI, URL, headers, cookies, and parameters fields in the output. Under these conditions previously, the adapter was copying these settings as specified in the Properties view. |
SB‑28051 | In previous releases, a Classcast Exception error could result at runtime when using any capture field in a Gather operator's input stream. This was fixed. |
Fixed in 7.6.0 | |
---|---|
Number | Resolution |
TIBCO StreamBase® 7.6.0 incorporated all fixes resolved in the release 7.5 series through 7.5.4, and the release 7.4 series through 7.4.5. | |
SB‑28498 | An issue where the Application Output view would fail to expand a list element that contained a file with null value was corrected. |
SB‑28447 | A possible Null Pointer Exception could occur when using a group-by field in the Additional Expressions tab of a Query operator. This was fixed. |
SB‑28325 |
Previously, running the EventFlow trace debugger on a module having at least
one Query Table could result in an Unable to parse
trace metadata file error. The cause was identified and corrected.
|
SB‑28312 | Studio would fail to open the JMS Configuration Editor when requested from an operator's Properties view if an XML editing session for one of the project's sbconf files was already open. Such requests were referred to the XML editing session. This no longer occurs, and, although it is against best practice, you can now have an XML editing session and a JMS Configuration Editor session open at the same time on the same sbconf files. |
SB‑28298 | Calling aggregate functions with aggregate functions as arguments was not reported as an error. These conditions now result in an error message. |
SB‑28254 | Using a Join operator with at least one of the input streams carrying an empty schema would cause an internal error. This was fixed. |
SB‑28201 | The new JMS Configuration Editor introduced in release 7.5.4 to support the new JMS and EMS adapters had its JMS versus EMS support determined by whether it was first opened from a JMS or EMS adapter's Properties view. This could inadvertently let an EMS adapter select a JMS provider. This behavior was corrected so that a dialog now warns you of the mismatch under the same circumstances. |
SB‑28187, SB‑28174 | The Copy Schema From dialog was updated to correctly import XML Schema (.xsd) files that define a list of tuples and importing from XML files was corrected and improved. |
SB‑28162 |
Running StreamBase Server as a Windows service would leave behind many
temporary directories whose names begin with sb-bindir* or sbdata-* . This
was fixed.
|
SB‑28146 | When using the HBase adapters, a lock issue could arise with the connect status message when using connect on startup. This was corrected. |
SB‑28137 | In previous releases, passing an expression to eval() that returned a tuple whose schema is different from the expected schema would result in ArrayIndexoutOfBound exceptions. This was corrected such that the same conditions now result in an error message reporting that the schemas don't match. |
SB‑27990 | Previously, using the API call DataType.forType(new BasicFunction(null, null, null, null ,null)) returned DataType.CAPTURE. This was corrected to return DataType.FUNCTION. |
SB‑27924 | In previous releases, custom Java operators or adapters that chose to reuse tuples could result in corrupted data in inner fields. This was corrected. |
SB‑27694 |
In previous releases, there were circumstances in which Studio or locally run
StreamBase Server would leave behind a number of temporary directories in the
system TMP directory, whose names all began with sb-bindir . The cause was identified and corrected.
|
SB‑27402 | The com.streambase.sb.TimeService interface was added to the Java Client API in release 7.4.0 to allow StreamBase JUnit tests to be devised for EventFlow modules with time sensitive operators such as a Metronome or an Aggregate operator with a time-based window. In 7.4.x and 7.5.x releases, this interface worked with a subset of operators. As of 7.6.0, the interface was updated and corrected to work with all time sensitive operators. Adding this updated support incidentally corrected a number of outstanding TimeService related issues. See API Changes for further details. |
SB‑27198 | In previous releases, when you tried to call functions that returned information on the state of the running module in an operator's property field, you could get compilation errors. Functions in this category include getPath(), getContainer(), getParallelRoot(), and so on. This was corrected. |
SB‑26242 | Previously, overriding a submodule's parameter with constants from the calling module would cause a typecheck exception. This was fixed. |
SB‑25591 | In previous releases, calling a null object as a function could cause operand-stack-underrun errors. This was fixed. |
SB‑25215 |
Previously, logical OR expressions with null ==
null on the right hand side could cause bytecode verification errors.
This was fixed.
|
Fixed in 7.5.6 | |
---|---|
Number | Resolution |
TIBCO StreamBase® 7.5.6 incorporates all fixes resolved in the release 7.4 series through 7.4.5. | |
SB‑28699 | In earlier releases of the .NET operator, an error caused garbled characters to appear when StreamBase received a string of encoded byte data. The cause was detected and resolved. |
SB‑28593 | In previous releases, the percentile() function in the StreamBase expression language was restricted to having a fixed maximum number of tuples. This could cause obscure IndexOutOfBoundException errors when the containing Aggregate operator handled more than 10,000 tuples. This was corrected, such that the maximum is now calculated as a percentage of the available JVM memory, as long as the maximum number of bytes used by one Aggregate operator does not exceed integer.MAX_VALUE, or 2,147,483,647. |
Fixed in 7.5.5 | |
---|---|
Number | Resolution |
TIBCO StreamBase® 7.5.5 incorporates all fixes resolved in the release 7.4 series through 7.4.4 and in the release 7.3 series through 7.3.12. | |
SB‑28505 | The CSV File Writer adapter could sometimes crash with a null pointer exception when checking for its output file with daily file rolling enabled. The cause was identified and corrected. |
SB‑27663 | In previous releases, the JMS Configuration Editor would allow you to select Destination Options as Queues, but still provide a value for the Subscriber Name field. This illogical combination would cause the adapter to fail to start. The combination is now prevented. |
SB‑28536 |
In previous releases, StreamBase was not passing on the truststore and truststore-password parameters for two-way SSL
authentication when entered in the .sbconf file
used by the sbproxy server.
This was corrected.
|
SB‑28493 | Complex uses of a number of TIBCO ActiveSpaces operators in the same application could result in a module lock deadlock. This underlying cause was corrected. |
SB‑28474 | Connection attempts using the CME Order Routing Adapter or the BM&FBovespa UMDF Input Adapter were seen to fail with "Error creating FAST session handler". The cause was identified and corrected. |
SB‑28447 | A possible Null Pointer Exception could occur when using a group-by field in the Additional Expressions tab of a Query operator. This was fixed. |
SB‑28312 | Studio would fail to open the JMS Configuration Editor when requested from an operator's Properties view if an XML editing session for one of the project's sbconf files was already open. Such requests were referred to the XML editing session. This no longer occurs, and, although it is against best practice, you can now have an XML editing session and a JMS Configuration Editor session open at the same time on the same sbconf files. |
SB‑28254 | Using a Join operator with at least one of the input streams carrying an empty schema would cause an internal error. This was fixed. |
SB‑28201 | The new JMS Configuration Editor introduced in release 7.5.4 to support the new JMS and EMS adapters had its JMS versus EMS support determined by whether it was first opened from a JMS or EMS adapter's Properties view. This could inadvertently let an EMS adapter select a JMS provider. This behavior was corrected so that a dialog now warns you of the mismatch under the same circumstances. |
SB‑28146 | When using the HBase adapters, a lock issue could arise with the connect status message when using connect on startup. This was corrected. |
SB‑27976 | For any adapter using the FIX protocol as implemented by the QuickFIX FIX engine, the SenderSubID, SenderLocationID, TargetSubID and TargetLocationID fields are now correctly set on tuples representing incoming FIX admin messages. |
SB‑27924 | In previous releases, custom Java operators or adapters that chose to reuse tuples could result in corrupted data in inner fields. This was corrected. |
SB‑27694 |
In previous releases, there were circumstances in which Studio or locally run
StreamBase Server would leave behind a number of temporary directories in the
system TMP directory, whose names all began with .sb-bindir . The cause was identified and corrected.
|
Fixed in 7.5.4 | |
---|---|
Number | Resolution |
TIBCO StreamBase® 7.5.4 incorporates all fixes resolved in the release 7.4 series through 7.4.4 and in the release 7.3 series through 7.3.12. | |
CQS‑3199 |
In previous releases, using a literal list expression that had all null
elements resulting in an index out of bounds exception. Now this condition
results in an error message List of type null is not
supported .
|
SB‑28156 | The MQTT adapter was incorrectly using the sslKeyStoreType parameter in the adapter configuration XML stored in the project's server configuration files. This was corrected. |
SB‑28138 | As of release 7.5.4, the Tuple2JSON operator now correctly unwraps then writes StreamBase escaped identifiers to JSON. |
SB‑28049 | The TIBCO ActiveSpaces operators were failing to map ActiveSpaces names that contained characters that violated the StreamBase naming rules. This was corrected. |
SB‑28006 |
In previous releases, if your input schema has a field named old , StreamBase could emit an ambiguous error or warning,
even if you qualified the reference to it with input.old in your Query operator. This was corrected.
|
SB‑28003 | The MQTT client adapter set was failing to respect the username, password, SSL, and clean session options while connecting to an MQTT resource. This was corrected. |
SB‑28000 | In the Web Server Input Adapter, request-response adapter instances configured as web sockets could fail to write before a read. This was fixed. |
SB‑27993 | Using the JMS-EMS adapters from release 7.5.3 and earlier, setting cache-destinations=false could break the ability to publish to destinations. This does not occur with the new JMS-EMS adapters of release 7.5.4 or later. |
SB‑27970 | Referencing operator parameters in module parameters caused an error in previous 7.5.x releases. This was fixed, restoring the behavior of the 7.4 and earlier release series. |
SB‑27000 | Using the JMS-EMS adapters from release 7.5.3 and earlier, a custom MessageConverter class would catch any TupleException and fail to pass it on to StreamBase Server. This situation does not arise in the new JMS-EMS adapters of release 7.5.4 and later. |
SB‑21104 | In previous releases, Studio would incorrectly report recursive references to modules when the Properties view and EventFlow editor attempted to typecheck the same module reference concurrently. This was fixed. |
Fixed in 7.5.3 | |
---|---|
Number | Resolution |
TIBCO StreamBase® 7.5.3 incorporates all fixes resolved in the release 7.4 series through 7.4.4 and in the release 7.3 series through 7.3.12. | |
SB‑27913 | The Web Reader adapter was not correctly returning the error stream message when it failed. This was fixed. |
SB‑27905 |
In previous releases, if you set one output port, perhaps port 1, of a Filter
operator to emit on condition true , then later
moved the true condition to another output port,
such as port 3, the operator could incorrectly see both ports 1 and 3 as the
true condition stream, potentially corrupting
the data sent over one or both ports. The cause was identified and corrected.
|
SB‑27904, SB‑27902 | Two fixes for the Tuple to JSON conversion routines were made: (1) JSON data with mixed numeric and string data types in a list can now be correctly converted into a list of strings. (2) JSON to tuple operations can now properly convert lists of lists of unnamed field data into list<list<tuple>> based on field index. These corrections affect several internal conversions in StreamBase as well as the Tuple2JSON adapter. |
SB‑27875 | The OSI PI adapter was failing to provide the OSI PI default login information when the user name and password fields of the adapter's Properties view were left blank. This was corrected. |
SB‑27873 | The OSI PI AF adapter was incorrectly gathering historical data. This was fixed such that the adapter now applies the requested date to both the database and the retrieval of data. |
SB‑27835, SB‑27528, SB‑27509 | Several issues with using the TIBCO StreamBase High-Performance FIX Engine were corrected, including a heartbeat loop issue, a problem starting a session when using a custom Acceptor module, and an Illegal Thread State Exception thrown. |
SB‑27809 | In previous releases, the byte array output from Tuple.serialize() of a generated-class sub-tuple would incorrectly include its parents' fields as well. This was fixed. |
SB‑25218 | In the Field Serializer global operator, inner tuple field data was not being correctly updated in subsequent uses of the operator. This was corrected. |
Fixed in 7.5.2 | |
---|---|
Number | Resolution |
TIBCO StreamBase® 7.5.2 incorporates all fixes resolved in the release 7.4 series through 7.4.4 and in the release 7.3 series through 7.3.12. | |
SB‑27817 | The feed simulation mechanism was incorrectly populating generated tuples based on index in the feed simulation specification's field list, and the corresponding index in the generated tuple's field list. If the field names were the same but in different orders, field values would be assigned to the wrong fields. This was fixed: field names are now correctly used instead of indexes. |
SB‑27777 |
Previously, in rare cases, a Query-Write operator could cause a spurious row
deletion in the table. The case was, In a write or update Query operator, if
an impure expression was used as a key's match expression, two different
values for the key could appear during the course of the write or update
operation. (An impure expression is one that evaluates to different values
every time it is called.) This led to unexpected and undefined behavior, such
as rows being deleted randomly.
The fix was to make sure StreamBase only evaluates the key's expression one time and thereafter caches its value, regardless of the key expression's purity. |
SB‑27753 | Generating a StreamBase bundle from Studio could produce a bundle that failed to start, while generating a bundle on the same project from the command line with the sbbundle command produced a normal working bundle. The cause was identified and corrected. |
SB‑27714 |
A rare corner case could result in a Duplicate
index error that had no visible cause or fix. The cause of the error
was identified and corrected. For the record, the rare case is: a hygienic
parent module has two module references, both of which are non-hygienic, and
one of the sub-module's tables is a placeholder and wants to be overridden by
the other sub-module's table.
|
SB‑27704 | The Bloomberg B-Pipe Input adapter now correctly handles cases where the same field name occurs in different data feeds. |
SB‑27702 |
The FxAll Relationship Trading Provider adapter was throwing a null pointer
exception when a message contained <FwdPoints></FwdPoints> , which resulted in a
null integer value. The cause was identified and corrected.
|
SB‑27685 | The TIBCO Spotfire Automation Services Output adapter now correctly handles files that have the UTF-8 BOM code as the first byte of the file. |
SB‑27684 | Including more than one asterisk in an expression would cause a typecheck error even when the specified expansions did not conflict. This was fixed. |
SB‑27681 | In the IBM WebSphere MQ Input adapter, the payload of incoming EBCDIC-encoded MQ messages was being translated to strings using the default character set instead of the appropriate EBCDIC character set. This was corrected. |
SB‑27680 | The Feed Simulation adapter was failing to convert fields of the list data type into list fields for the target input stream. This was fixed. |
SB‑27670 | The Bidirectional Socket adapter was updated to provide speed improvements. |
SB‑27643 |
In previous releases, if a schema field had the same name as a built-in or
custom Java function, calling that name resulted in a warning about an
ambiguous reference. Starting with this release, StreamBase's name resolution
order is honored without a message. That is, the built-in or custom function
is always called first. You can disambiguate fields named with a reserved
term by adding a prefix to the field name. For example, a field named
random can be distinguished from the internal
random() function by referencing it as input.random .
|
SB‑27635 |
Starting a LiveView project could result in a java.util.ConcurrentModificationException exception. The
cause was identified and corrected.
|
SB‑27514 | A High Performance FIX Engine session with a mid-day session gap could prevent an acceptor from accepting connections. The cause was identified and corrected. |
SB‑27513 | The High Performance FIX engine could fail to disconnect initiators after a scheduled stop of a session. This was fixed. |
SB‑27433 | The Deutsche Bank AutobahnFX Classic FIX execution handler (part of the Trading Components Framework) was failing to process SWAP trade requests. This was corrected. |
SB‑27287 | The CSV File Reader adapter now correctly reports the line number of the source file in error messages. |
SB‑27318 | Releases 7.5.0 and 7.5.1 did not fully take into account an OS X Yosemite change in the way OS X Yosemite handles LD_LIBRARY_PATH entries. In OS X versions prior to Yosemite, any entries added to the LD_LIBRARY_PATH were automatically added to the DYLD_LIBRARY_PATH; but starting with Yosemite, such double adds to both paths must be handled manually. This only affects OS X users building client applications or custom functions with C++ on OS X. |
Fixed in 7.5.1 | |
---|---|
Number | Resolution |
TIBCO StreamBase® 7.5.1 incorporates all fixes resolved in the release 7.4 series through 7.4.4 and in the release 7.3 series through 7.3.12. | |
SB‑27612 | In release 7.5.0, StreamBase Studio's remote execution feature failed to connect to remote StreamBase Servers. The cause was identified and corrected. |
SB‑27581 | The Log adapter was producing an error message if the Compress Frequent Messages option was enabled. This was fixed. |
SB‑27536 | The Web Server Request adapter was emitting incorrect payloads when it encountered a large concurrent request count with a large body payload. The cause was identified and corrected. |
SB‑27487 |
The sbprofile -f filter option, which matches a regular expression against
operator and queue names to restrict output, was not working for streams.
This was corrected.
|
SB‑27481 | The sbmonitor command-line tool was showing multiple entries for the same stream. This was fixed. |
SB‑27456 | The output order of table columns returned by StreamSQL SELECT statements and EventFlow Query operators was arbitrary when indexes were hashed. This was corrected to preserve the order of input columns on output. This fix restores the default behavior of StreamBase 7.2. |
SB‑27441 | Calling unique() on the output of another list function sometimes caused a code generation error or a null pointer exception at run time. This was fixed. |
SB‑27439 | POST requests to the TIBCO StreamBase® Web Server Request adapter could generate duplicate requests when one of the endpoints was subordinated to another one that failed to respond quickly enough. This was fixed. |
SB‑27436 | The TIBCO StreamBase® Web Server Request adapter now returns an HTTP ONLY field for cookies. Cookie fields were re-ordered to enable their direct streaming into the response side. For other updates to this adapter, see New and Noteworthy. |
SB‑27375 | In release 7.5.0, the Thomson Reuters demo in the SB Demos perspective was failing to send data to its Java client. This was corrected. |
SB‑26408 | StreamBase Studio reported spurious typecheck errors for valid parent schemas when passed down through multiple levels of module imports. This was corrected. |
SB‑25565 | The Order property of Query Delete operations did not function correctly when the direction was selected. This was fixed. |
SB‑25403 |
The sbc readTable -v command
displayed tupleid=0 for all dequeued tuples,
rather than a sequence of numeric values. You can now specify that sequential
or hashed values be assigned for returned tuple IDs by setting the Java property
streambase.appgen.tupleid to sequential or hash ,
respectively. If you do not set this property, tuple IDs are still all
reported as 0. For further information, see sbc.
|
Fixed in 7.5.0 | |
---|---|
Number | Resolution |
TIBCO StreamBase® 7.5.0 incorporates all fixes resolved in the release 7.4 series through 7.4.3 and in the release 7.3 series through 7.3.12. | |
SB‑27381 | The TIBCO StreamBase® Adapter for Exegy was ignoring its isAggregated flag for subscription requests, causing prices to be returned in the default format (merged or expanded) of the XCAPI library. (The library returns expanded prices by default in XCAPI versions prior to 3.2.0 and returns merged (aggregated) prices thereafter.) This was fixed. |
SB‑27305 | Removing an arc issuing from a sub-module could make an application's internal state inconsistent with its EventFlow representation. This was corrected. |
SB‑27303 | Under certain conditions, removing a Filter operator predicate from the Predicate Settings tab triggered a null pointer exception. This was fixed. |
SB‑27297 | Previously, when a Query operator's input schema was not compatible with the schema of the table that it was reading or writing, a compile error resulted. Now, a typechecking error is generated that describes the problem. In addition, implicit casts to the string data type, which was formerly deprecated, is now disallowed. Instead of generating a warning, attempts at such casts now produce a typecheck error. |
SB‑27292 |
Previously, if the schema of a stream in a hygienic inner module did not match that of the
outer module, StreamBase would attempt to rectify the mismatch and proceed
without issuing an error. In some situations, however, this could cause
CautionIf any of your applications have been relying on this lack of strictness, they may now start to fail typechecking. Reported will be: the source and target of the mismatched streams, the number of fields in each, and a list of schemas. To fix, either change the schemas supplied to and expected from modules to have identical field names and data types (order of fields is not important), or mark the inner module as non-hygienic. For more information, see mark the inner module as non-hygienic. |
SB‑27288 | The TIBCO StreamBase® Adapter for Deutsche Bank Autobahn FX Rapid was reporting quotes as Indicative instead of Tradable. This was fixed. |
SB‑27285 | You can now define a dynamic variable without providing an update expression. Whatever initial value you provide for the variable will not change. Formerly, doing this raised an error and Studio prompted you to enter an expression for updating the variable. |
SB‑27256 | In certain use cases, the CSV File Reader input adapter caused typecheck errors because it hard-coded schema names for outbound tuples that could clash with existing schema names. This was corrected. |
SB‑27188 | Previously, when you used expressions as secondary table indexes, those indexes would not be used, causing a table scan to be performed. This was fixed. |
SB‑27090 |
To fix a divide-by-zero issue, the slope() and
intercept() functions were modified to return
zero when an Aggregate window contains a single point (that is, one row) or
multiple identical points (that is, duplicate rows containing the same
values).
|
SB‑27042 |
Parameter substitution in previous releases consisted of simple text
substitution at runtime. This caused a situation where parameters that
referenced other parameters saw only the values of the referenced parameters, not the
parameter itself. For example, an expression might include:
top=3, bot=2, div=${top}/${bot}But at runtime, ${div} was actually stored as
div=3/2 . Thus, when you updated the values of
${top} or
${bot} , those updates were not reflected in
${div} . Parameter
substitution was corrected to produce the expected results.
|
SB‑26912 |
Previously, the CSV File Writer output adapter provided no notification if
its output file was deleted during execution, causing its output to be
silently discarded. This is fixed, so that now this condition generates a
status event of type Error on the event port.
|
SB‑26885 | The File Reader Input adapter was updated to handle fast rates of incoming control port tuples specifying the names of files to be read. Prior to this fix, the adapter might read the same file multiple times instead of processing multiple files in sequence. |
SB‑26798 |
In some situations, such as in Aggregate windows, assigning values to tuple
subfields could cause all of the fields to acquire the same value. For
example, specifying:
(1 AS a, 2 AS b, 3 AS c) AS myTuple might produce an erroneous result such as: (1 AS a, 1 AS b, 1 AS c) This was corrected. |
SB‑26627 |
Exporting a bundle from StreamBase Studio could fail with a class loader
exception such as com.streambase.fastjson.parser.Feature; cannot be loaded via the
given classloader . This was fixed.
|
SB‑26623 |
Previously, jsbc dequeue when
used with the -v option (to output
human-readable tuples) could not output tuples in JSON format. The fix also
now allows you to output JSON tuples from sbc
dequeue. The sbc utility can now input and issue tuples
in JSON format with the -v option, which only
jsbc could do previously.
|
SB‑26469 |
Previously, in a field grid, when you DECLAREd a field having the name of an
existing field and then referenced the field, you did not get any warning or
error. Now you get warned that this reference is ambiguous. For example:
the reference to field "x" is ambiguous; you must qualify the field reference with one of "input.", "input1.", "new." |
SB‑25101 | You can now declare an aggregate function and reuse it. Previously, only simple functions could be declared in the Aggregate Functions tab of an Aggregate operator. |
SB‑24925 |
Previously, a field that you included in the output grid of a Map or other
operator could not be referenced from subsequent entries within that grid.
This is now possible.
Note
|
SB‑22255 |
In previous releases, an unused import warning
would be issued in Studio for EventFlow modules that defined a constant or
function that referenced an imported named schema. This was corrected.
|
SB‑20430 | A CancelledKeyException was sometimes thrown by the StreamBase HTTP Server for a key that was no longer valid. This was fixed to eliminate such exceptions. |
See the StreamBase Release Note Archives for the list of issues resolved in previous releases.
This section describes known limitations in the current release of TIBCO StreamBase®. Each item includes a tracking number, description, and whenever possible, one or more workarounds.
Known limitations for using the EventFlow debugger are described separately, in the Limitations, Tips, and Tricks section of the Using the EventFlow Debugger page.
SB‑29576 | Web Server Request adapter in Maven builds needs a certain jetty.jar | |
Description | When building a StreamBase application with Maven, where the application uses the Web Server Request adapter, the wrong version of the required Jetty JAR file is selected by default. | |
Workaround | The StreamBase distribution includes two versions of the Jetty JAR file for different purposes. Configure your Maven POM file to require the Jetty JAR file shipped in $STREAMBASE_HOME/lib/ext for use with this adapter. | |
SB‑29275 | In 7.5.x, features using .NET require JDK 7. | |
Description | The 7.5.x release series ships with an embedded JDK 7 version. All .NET functionality in StreamBase, including the OSIsoft PI adapter, work fine in 7.5.x with a JDK 7 version. However, if you configure StreamBase 7.5.x to use an external JDK 8, .NET functionality fails. | |
Workaround | The 7.6.x release series ships with an embedded JDK 8 version, and all .NET functionality was updated to work with JDK 8 on that series. If you must use both JDK 8 and a StreamBase .NET feature, TIBCO recommends upgrading your StreamBase installation to the latest 7.6.x release. | |
SB‑29050 | Error when debug stepping into or stepping over a Decision Table operator. | |
Description | When using EventFlow debugging, stepping into or over a Decision Table operator is not supported. | |
Workaround | Set your breakpoints upstream or downstream. Also, consider using the features of the Decision Table Analyzer to get a debug-like view of how the operator responds to different input tuples. | |
SB‑28856 | Deleting decision table rows does not re-number rule IDs | |
Description | When using the Decision Table editor to delete and then add a new decision table rule, the rule ID does not renumber. For example, by deleting row 5 and adding a new row, the rule ID numbering is now 1...4, 6. | |
Workaround | None. | |
SB‑28669 | Error message: Grows beyond 64KB. | |
Description |
In rare cases, compiling small StreamBase applications can produce an error
message containing the words Grows beyond 64KB .
|
|
Workaround | Contact TIBCO StreamBase Technical Support for a workaround for this issue. | |
SB‑28598 | Multi-container StreamBase applications cannot use the same ActiveSpaces metaspace. | |
Description |
StreamBase applications deployed with multiple containers receive
metaspace already exists errors when attempting
to connect to the same TIBCO ActiveSpaces metaspace from different
containers.
|
|
Workaround | None. | |
SB‑28452 | Delta stream arc limitations in the EventFlow Debugger. | |
Description | If a delta stream arc is a direct connection between a Query Table and an Output Stream, and if that arc has a Debugger breakpoint, the breakpoint is not hit at during debugging with the EventFlow Debugger. Similarly, while debugging, stepping over to try to reach that arc does not suspend on that arc. | |
Workaround | Insert a no-op Map operator between the Query Table and the Output Stream. Then a breakpoint on the arc between the Query Table and the Map does work, and stepping over reaches that arc as well. | |
SB‑27517 | sbd --eval treats initial hyphen as an sbd option on Windows | |
Description | In the rare case that you have an expression to evaluate at the Windows Command Prompt with sbd --eval where (a) the expression to evaluate begins with a hyphen, such as a math expression '-2+5', and (b) you use single quotes instead of double quotes, then sbd interprets the initial hyphen as the start of another sbd option. | |
Workaround | 1. Rewrite your expression to avoid the initial hyphen. 2. Use double quotes instead of single. | |
SB‑27488 | Runtime exception when using Drools operator with sbd under Java 8. | |
Description |
StreamBase applications containing Drools operators may compile under Java 8
but fail with a wrong class format exception
when they run.
|
|
Workaround | Run the application under Java 7. | |
SB‑27278 | Custom timestamp formats for the sbc command may produce unexpected results or fail on Windows. | |
Description |
On Windows, the C++-based sbc
command returns different results compared to the Java-based jsbc command for certain custom timestamp
formats, such as %F (which on Windows needs to
be %Y-%m-%d ) and %z
(which returns a time zone identifier instead of its offset), and might
return an error.
|
|
Workaround | Use Windows-specific formats in the few cases where format string options differ from OS X and Linux formats. | |
SB‑27096 | Standalone Help Viewer and sbhelp not provided. | |
Description | Starting with StreamBase 7.5.0, the standalone Help Viewer on Windows, and the sbhelp utility on OS X and Linux, no longer function. The move to Eclipse 4.4 as a base for StreamBase Studio caused complications that were solved for Studio, but not for the Help Viewer. | |
Workaround | Use the Eclipse Help provided as part of StreamBase Studio, or the website version of the documentation, as described in Using the Help System | |
SB‑26629 | RPM installation method issues on RHEL 7 | |
Description |
StreamBase and Live Datamart are supported on Red Hat Enterprise Linux
version 7.x. The archive installer is the recommended installation method. If
you use the RPM installation method, RHEL 7 issues several warning messages
during installation that complain about file removal failures, and issues an
overall warning that RHEL 7 "may not be compatible with this version of
StreamBase."
Despite these warnings, the installation does succeed. The only consequence
is that |
|
Workaround | Remove StreamBase directories manually to uninstall an RPM installation on RHEL 7. Otherwise, all StreamBase and Live Datamart processes run as expected on RHEL 7. | |
SB‑26927 |
<MyNamedSchema> is not a function that can be
called error.
|
|
Description |
In compiling the updating expression for a dynamic variable where the
expression references a named schema, if a field in the tuple presented by
the updating stream also has the same name as the named schema used in the
expression, the field is instead evaluated as a function. This raises the
error <MyNamedSchema> is not a function that can
be called . This compilation behavior and language ambiguity was
introduced with the function data type in StreamBase 7.4.0.
|
|
Workaround | The required migration step is to rename either the field or the named schema to eliminate the ambiguity. | |
SB‑26627 | Exception when exporting application bundle from StreamBase Studio with | →|
Description | Exporting an application bundle in StreamBase Studio can raise a class loader error, preventing the operation. | |
Workaround | Run all the apps in the project before exporting the bundle from StreamBase Studio. If that fails, use the sbbundle command line tool to export the bundle. | |
SB‑26237 | Constant definitions used as component properties are not used at runtime. | |
Description | StreamBase Studio properly typechecks defined constants when used in operator properties, but at runtime substitutes their names instead of their values. | |
Workaround | Do not use defined constants when specifying operator properties. | |
SB‑26017 | Asynchronous timeouts for Gather operators in parallel applications can be inaccurate | |
Description | High availability applications that include Gather operators may incorrectly compute timeout intervals because the operator relies on now() instead of calling out to the parallel scheduling service. | |
Workaround | None | |
SB‑25527 | Extension points cannot be externally configured for deployed .sbar files. | |
Description |
It is currently not possible to configure extension points for precompiled
StreamBase applications deployed as .sbar
files. Attempting to do so raises the error: SBAR file
for container < .
|
|
Workaround | None | |
SB‑25403 | Tuple IDs returned by sbc readTable all contain zero. | |
Description |
The sbc readTable -v command
displays tupleid=0 for all tuples retrieved from
a query table, rather than a sequence of numeric values.
|
|
Workaround | To obtain sequential values for tuple IDs, run StreamBase server in a Java 8 environment. | |
SB‑23835 | Command line bundler does not find JUnit jar | |
Description | When referenced by the usual Eclipse JUnit library, the junit.jar is not found by the bundler from the command line using the -P option. | |
Workaround |
Manually add junit.jar (from %STREAMBASE_HOME%\lib ) as an external .jar reference in StreamBase Studio (not to the .sbconf file) to enable the command-line bundler to find it
on the build path. Also add rfa.jar from
%STREAMBASE_HOME%\lib\bootext in the same way.
|
|
SB‑23741 | Studio crashes on older 32-bit Linux distributions. | |
Description | A reported Eclipse bug causes Studio to crash on 32-bit Linux when attempting to render a non-empty EventFlow application. This problem is seen with 32-bit RHEL 4 and SuSE 10 distributions, and only with Studio 7.3.0 or later, where the base Eclipse installation is 3.8. | |
Workaround | Try using a 64-bit version of the same distributions, where this problem does not occur. | |
SB‑22297 | Commented-out error input streams consume error tuples. | |
Description | An error input stream, despite being disabled with the EventFlow comment-out feature, still catches errors thrown, but consumes any incoming errors and fails to pass them on. | |
Workaround | To temporarily disable error streams, copy them to a placeholder module and remove them from the active module. | |
SB‑21843 | In the TableAccessor API, ClassCastException is thrown if not using a Tuple from TableAccessor#createRow. | |
Description |
If methods in the com.streambase.sb.operator.TableAccessor interface that
accept a Tuple are not provided a Tuple retrieved from TableAccessor#createRow , a ClassCastException may be
thrown by the API.
|
|
Workaround |
Always use TableAccessor#createRow when using
TableAccessor API methods.
|
|
SB‑21107 | Problems using activemq-all.jar. | |
Description | Projects that include references to the activemq jar file may not load slf4j or exhibit other classpath problems. | |
Workaround | Replace the actviemq library with the individual jar files provided by apache.org for activemq, which are listed at http://activemq.apache.org/version-5-initial-configuration.html.. | |
SB‑20449 | Display issues with years before 2 AD. | |
Description | The timestamp data type can hold timestamp values in the range -(2^62) to (2^62)-1, and can successfully display any future date in the next 146 million years and any past date to around year 2 AD. However, the year value for dates earlier than 2 AD may not display correctly. | |
Workaround | None. | |
SB‑18294 | Union operator: sub-field order of tuple fields must match with strict options. | |
Description | When using the Union operator with its Strict union or Declared schema options, the order of sub-fields of tuple fields must match exactly. This is in contrast with the default Loose union option, where strict sub-field ordering is no longer required. | |
Workaround | None. | |
SB‑18189 | Some Windows UI themes fail to render borders. | |
Description | On some Windows UI themes, such as the Windows XP Classic theme, some UI elements are drawn without a border. This affects the JDBC SQL text box of the Query operator, among others. | |
Workaround | Try a different Windows theme. | |
SB‑17414 | Order of layout parameters changed one time after import into 6.5 or later. | |
Description |
When importing an EventFlow module created with StreamBase 6.4 or earlier
into StreamBase 6.5 or later, some layout parameter lines may shift positions
in the .sblayout file (or .sbapp file if you do not use separate layout files). This
may affect difference comparisons or version control systems.
|
|
Workaround | The reordering of layout parameter lines is a one-time occurrence after the first save in StreamBase 6.5 or later. Thereafter, these lines are stored consistently with each save. | |
SB‑16594 | Extract as Module feature copies items instead of importing them. | |
Description | The Extract as Module feature makes a copy of the source module's definitions and named schemas, and places the copies in the newly created module. Best practice would be to import those features from the source module to the new module, and to copy all imports from the source to new modules. | |
Workaround | After using Extract as Module, manually convert the copied definitions and named schemas to imports. | |
SB‑16555 | Doubled menu items in Windows Start menu. | |
Description |
The Start menu should be cleared when a previous StreamBase release is
uninstalled, so that you only see menu entries for the most recently
installed release. However, on systems with more than one StreamBase release
installed (such as releases 6.4 and 6.5), the uninstaller can sometimes fail
to remove the old entries from the Start menu. In previous releases, this was
not an problem, because the new installer (for, say, 6.5.3) would simply
overwrite the same entries for the previously installed release (say, 6.5.1).
However, starting with release 6.5.4, the StreamBase installer now adds the release number to Start menu entries for the StreamBase Command Prompt and for links to documentation. If an uninstaller fails to clean up the Start menu for a previous 6.5 release, you may see both old and new style links. |
|
Workaround | Uninstall the most recently installed release (such as 6.5.4). Manually remove its entire Start menu folder (such as | → → ), then reinstall the new release.|
SB‑14862 |
Custom Java operators and adapters cannot include their own janino.jar .
|
|
Description |
The StreamBase Server executable, sbd[.exe], incorporates a customized
version of the Janino libraries that include bug fixes that have not yet been
absorbed by the Janino project. If you attempt to include the standard
janino.jar implementation of Janino as part of
a custom operator or adapter, that JAR file conflicts with the version
embedded in sbd.
|
|
Workaround |
Call Janino as part of StreamBase's server.jar ,
or see http://code.google.com/p/janino-streambase for public
access to StreamBase's Janino bug fixes.
|
|
SB‑14239 | Recordings in Studio fail to play back against streams with imported schemas. | |
Description | Since release 6.4.0, applications can use the Module Imports feature of the EventFlow Editor's Definitions tab to import schemas. If you use the Studio Recordings view to record the operation of such an application, it fails to play back. | |
Workaround | Create a local copy of the imported schema in the application module that contains the stream, and specify the copy for use by the stream. Then re-record the application. | |
SB‑14133 | sb-config --cxx returns a setting for G++ 4.3, 4.4, or 4.5 on newer Linux distributions | |
Description | On Linux, in StreamBase samples that build C++ code, some of the example Makefiles show sb-config --cxx as the correct usage to determine the G++ compiler to use. On newer Linux distributions, this command returns the distribution's default G++ 4.3, 4.4, or 4.5 compiler, which is not supported for building StreamBase client code, and sb-config does not honor the CC and CXX environment variables. | |
Workaround |
On such systems, install GCC and G++ 4.2, and edit the Makefiles to specify
CXX=g++-4.2 .
|
|
SB‑13398 | Filter operators with very large predicate settings may result in a runtime EvalException error. | |
Description |
Filter operators with several output ports and complex expressions to
evaluate for each port may result in a com.streambase.sb.runtime.exceptions.EvalException error
when attempting to run the application that contains such a filter.
|
|
Workaround | Add another Filter operator and split the predicate settings between the two Filter operators. | |
SB‑13303 | Reuters RFA Configuration File wizard appears to not connect under Windows Vista or Windows 7. | |
Description | Under Windows Vista and Windows 7, you can run the Reuters RFA Configuration File wizard, but the wizard's Test Connectivity page shows a red X and the Test Connection button remains dimmed. | |
Workaround | This wizard makes changes to the Windows registry, and under the Vista and Windows 7 security model, registry changes require administrator permissions. For these operating systems, use the procedure described in Special Steps for Windows Vista and 7. | |
SB‑13113 | Application output view does not display UTF-8 characters. | |
Description | Both StreamBase Server and StreamBase Studio are fully capable of processing and displaying Unicode character sets, but neither is set to do so by default. | |
Workaround | Follow the instructions in Unicode Support to configure StreamBase Server, Studio, and any StreamBase client applications to process the UTF-8 character set. | |
SB‑13021 | JDBC database errors related to string lengths. | |
Description | Due to the removal of string lengths in StreamBase as of release 6.3, some static checking of JDBC table sizes is no longer possible. This can lead to database-specific errors, possibly including data truncation, if a StreamBase application attempts to insert into a JDBC table string values that are too wide for the JDBC table's schema. | |
Workaround | None. | |
SB‑12824 | Java and C++ format doubles differently. | |
Description |
When displaying integer-like values of type double, Java code outputs the
value with a decimal point and zero appended (34.0), whereas C++ code outputs
the same value without those features (34). Thus, the same double values
output to stdout with sbc dequeue and jsbc dequeue are formatted differently.
|
|
Workaround | None. | |
SB‑12401 | Clients connecting to sbproxy with misconfigured SSL may hang. | |
Description | Client applications attempting to make a secure connection to StreamBase Server by means of the sbproxy server may hang if the client or server is not configured to support SSL. | |
Workaround | Carefully review your SSL configuration setup. | |
SB‑12136 | On 32-bit Windows, some third-party applications can interfere with StreamBase Server starting. | |
Description | In recent releases, StreamBase Server is started by default with a requested maximum memory size of 512 or 1024 MB. Certain third-party applications, including Apple's Bonjour program, load themselves in the middle of available RAM, which can prevent StreamBase Server from reserving a contiguous block of memory. | |
Workaround | You can (1) reduce StreamBase Server's maximum memory size request by adjusting the server configuration file as described in Java VM Memory Settings, (2) remove the competing program, such as Bonjour, or (3) upgrade to a supported 64-bit platform. | |
SB‑11964 | Case-sensitive Unicode regular expressions require Java 1.6. | |
Description |
When running StreamBase with Java 1.5, with Unicode support enabled as
described in Unicode Support, the expression language function behaves as
if an ignore-case option was enabled.
|
|
Workaround | To have both case-sensitive regular expressions and Unicode support, you must run StreamBase with Java 1.6, which is the default JDK shipped with StreamBase. | |
SB‑11245 | RFA/Java Configuration: Test Connection sometimes fails with RTIC servers. | |
Description | The RFA/Java Configuration Wizard and Reuters Schema Designer, under certain conditions when used with an RTIC server, fail to access the server. This occurs when using the Configuration Wizard's Test Connection button and the Schema Designer's Discover Services and Start FIDs Lookup tools. | |
Workaround | None needed. Despite the reported connection failures, the RFA/Java configuration file generated by the wizard is valid and usable by the Reuters RMDS subscribing adapter. | |
SB‑11117 | Test Editor might not update changes in an open Feed Simulation file. | |
Description | If a StreamBase Feed Simulation file is modified while a Test Editor is open that references that feed simulation, the Test Editor may not update its contents until it is closed and reopened. | |
Workaround | Close the Test Editor before editing a Feed Simulation file referenced in the test. | |
SB‑10983 | Reuters RFA Publishing Adapter not shipped for Linux | |
Description | Because of a change in C++ libraries, the Reuters RFA Publishing external adapter is not shipped for Linux in StreamBase 6.x or 7.x. | |
Workaround | Use the new Reuters RMDS Publishing embedded adapter. | |
SB‑10792 | The Query operator converts a JDBC data type differently when using explicit schemas than when using database data types. | |
Description |
When explicit schemas are used, the Query operator does not use database
metadata to determine the mapping between JDBC data types and StreamBase data
types. The JDBC data type Types.TIME is normally
converted to an interval timestamp since it has a time, but no date
component. But when explicit schemas are used, there is no database type
information, so Types.TIME is converted to an
absolute timestamp.
|
|
Workaround | None. | |
SB‑10486 | Hierarchical data restrictions. | |
Description | Patterns by value do not support using the tuple data type for their on-value portion. Similarly, tuple subfields cannot be used as the index or primary key of a Query Table. | |
Workaround | Design schemas so that the intended sort field or key is a top-level numeric or timestamp field, as described in StreamBase Pattern Matching Language. | |
SB‑10363 | No StreamBase data type corresponding to Sybase timestamp. | |
Description |
When used with Sybase data sources, StreamSQL fails to convert timestamps,
resulting in typecheck errors. This is because the Sybase timestamp is based on the Sybase varbinary data type.
|
|
Workaround |
In StreamSQL code that will be used for Sybase data sources, use the
Sybase datetime
data type instead of timestamp .
|
|
SB‑8640 | Java Operator with zero inputs does nothing. | |
Description |
While it is not an error to create a Java operator with zero input ports, the
processTuple method will never be called, and
thus the Java operator can never emit any tuples.
|
|
Workaround | None. | |
SB‑8297 | Files edited outside StreamBase Studio are not refreshed in Studio automatically. | |
Description |
For .sbapp and .sbfs files that were created using StreamBase Studio and
are still open in Studio, modifications made using an external editor are not
automatically refreshed in the current Studio Editor session.
|
|
Workaround | If edits are made outside of Studio and you now want to use the latest file, right-click the project that contains the changes you made and select Refresh. | |
SB‑7148 | Invalid byte error when opening EventFlow application. | |
Description |
Studio sometimes fails to open an EventFlow application with this error:
|
|
Workaround |
Perform the following steps to recover:
|
|
SB‑7075 | Changing perspectives can rearrange the Studio toolbar. | |
Description | The position of toolbar sections can change when you go from perspective to perspective, especially when going from the Authoring to the Demo perspective and back. | |
Workaround | Eclipse toolbars do not have fixed locations, so this is expected behavior. | |
SB‑6862 | Not all databases have native blob support. | |
Description | For example, Microsoft SQL Server and Sybase do not have blob support. For these databases, you can write blobs into varbinary and possibly other types. But when blobs are read from a select statement, they are returned as strings, not blobs. | |
Workaround | Add a Map operator and convert the string to a blob. | |
SB‑6346 | Custom function C++ code typechecking is delayed until the application is generated. | |
Description | Most portions of a StreamBase application are typechecked in real time as you add features to an EventFlow or StreamSQL application. However, starting with release 5.0, typechecking for a custom function written in C++ is delayed until the application is generated and run. | |
Workaround | None. Be aware that typechecking errors may not be reported as usual when using custom C++ functions. | |
SB‑5882 | Tuple dimensions do not reset counter when another dimension closes a window early. | |
Description | A tuple-based dimension that closes due to other dimensions (for example, after another dimension times out) does not reset its counter. When this happens, the next window will close based on the total number of tuples received, resulting in a partially full dimension. | |
Workaround | None. | |
SB‑5779 | SBAPP-to-SSQL Conversion Assistant resets module parameters to default values. | |
Description | If you run the SBAPP-to-SSQL Conversion Assistant on an EventFlow application that makes use of module parameter references, the resulting StreamSQL application does not have any module parameter references. They are replaced by their default values. | |
Workaround | After the conversion, edit the StreamSQL file to add the non-default module parameter values. | |
SB‑5749 | Feed Simulation Editor's data rate edit and save Issue on Linux. | |
Description | In StreamBase Studio, the Feed Simulation Editor lets you set the rate in number of tuples per second at which data will be generated for a stream. On Linux only, if you use the keyboard to enter an integer in the Data Rate text box, the new value might not be saved. | |
Workaround | After clicking into the text box and entering the value, press Enter or change the cursor's focus (for example, press Tab). Then press the Save icon or enter Ctrl+S. Note that if you press Ctrl+S while your cursor is within the Data Rate text box, the new value is not saved. You must press Ctrl+S again. | |
SB‑4931 | SBAPP-to-SSQL Conversion Assistant does not support parallel operators. | |
Description | If your EventFlow application file has individual operators that are marked for parallel operation, the SBAPP-to-SSQL Conversion Assistant cannot generate equivalent functionality in the generated StreamSQL application because there is no direct analogy for parallel operators in StreamSQL. | |
Workaround |
After the conversion, if appropriate for your application (no dependencies on
data in other operations), you can use an APPLY
PARALLEL MODULE statement or APPLY PARALLEL
JDBC statement in the StreamSQL file. For details on the APPLY statement, see the StreamSQL Guide.
|
|
SB‑4559 | Join timeout is not asynchronous. | |
Description | Join timeout in the Join operator is not asynchronous. That is, the Join operator does not remove a tuple from its buffer until the timeout has passed and another tuple arrives on the same input stream. Tuples received on one input stream do not affect the buffer of the other input stream. | |
Workaround | None. | |
SB‑4225 | Some disk drive configurations can corrupt disk-based Query Tables if power fails. | |
Description | Some caching disk drives do not guarantee the sequencing of disk writes, nor do they guarantee that all the writes to the drive have actually happened. This behavior improves disk performance, but at the risk of data corruption in the event of a power outage or equipment failure. StreamBase is vulnerable to this kind of data corruption if your StreamBase application uses disk-based Query Tables. | |
Workaround | Disk drives with this behavior usually have a driver-level setting to turn this capability on or off. For example, the driver may present you with a check box labeled Enable write caching on the disk. Unchecking this box would prevent the problem from occurring. | |
SB‑3955 | Finding sbd process failure details. | |
Description | When StreamBase Studio runs an application, it launches the server process in the background. If the server process fails for any reason, Studio tries to report the reason to you. However, the actual message that Studio displays may not contain enough information,depending on the failure. | |
Workaround | To get more information about the reason for the sbd process failure, open the Eclipse Error Log View, as described in Error Log View. | |
SB‑3585 | Inconsistent support for undo in StreamBase Studio. | |
Description | Many editing operations in Studio cannot be undone. This includes operations such as copying schemas, editing definitions, editing feed simulations, and so on. | |
Workaround | The Revert command in the File menu can be used to undo all changes since the last time a file was saved. | |
SB‑2931 |
Relocatable RPMs install incorrect symbolic links in /usr .
|
|
Description |
The Linux RPM packages are relocatable. This means that the default
installation location of /opt/streambase can be
changed to a different location. However, if this is done, symbolic links are
still installed in /usr/bin and /usr/lib that point to /opt/streambase .
|
|
Workaround | Either edit the symbolic link by hand, or use the archive file installer instead of the RPMs to install StreamBase on Linux. | |
SB‑2507 | Java Client library IOException when client program is suspended. | |
Description |
A program using the StreamBase Java Client library may receive an unexpected
IOException if it is suspended (using either Ctrl+Z, or kill
-SIGSTOP ). The IOException is thrown when the program is resumed, or
placed in the background. The exception may be thrown even if there is no
network traffic at the time. This issue does not apply to Windows systems.
|
|
Workaround | Do not suspend StreamBase clients written in Java. | |
SB‑1969 | StreamBase Studio on Windows triggers Windows firewall when running Server. | |
Description | Users of StreamBase Studio on Windows may find that the Windows Firewall, or a third-party firewall product, prompts for permission to continue when first starting StreamBase Server. The message may refer to javaw or to StreamBase Server by name. This is expected behavior of Windows firewalls. You must grant the requested permission in order to continue using StreamBase Server on this machine. | |
Workaround | After granting permission once, you should not be prompted about this again. | |
SB‑1769 |
LockDirectoryException error encountered when
starting StreamBase Server.
|
|
Description |
There may be a number of cases when you would encounter the
LockDirectoryException error. If the message indicates File exists , either another instance of StreamBase Server is
currently running or the prior instance of Server was improperly shut down.
|
|
Workaround |
If another StreamBase Server instance is running, change the server
configuration file to point the datadir element
to a different directory. If there is no other Server instance running, you
must manually delete the directory named in the File
exists message.
|
|
SB‑1289 | IPv6 addresses not supported. | |
Description | StreamBase Server can only connect to IPv4 addresses. If you try to connect using IPv6 addresses, the connection is refused. | |
Workaround | None. | |
SB‑1164 | Issues with certain older Linux kernel versions. | |
Description | Linux kernel versions 2.6.8-10 have a known bug in their thread handling code. This bug can cause sbd to exit immediately after servicing its first client request. For more information, see http://www.ussg.iu.edu/hypermail/linux/kernel/0410.2/1650.html. | |
Workaround | This bug was fixed in Linux kernel 2.6.11. This does not affect the Linux distributions currently supported by StreamBase. If you are running an older kernel in the 2.6.8-10 range, then set the environment variable STREAMBASE_IGNORE_SIGHUP=1 to work around this problem. Set the variable in the login environment in which StreamBase Server will run. | |
SB‑1039 | C++ code is not binary compatible between releases. | |
Description |
If you use either the C++ Client library, plug-in functions, or plug-in
aggregates, you must recompile them from source in order to use them in each
new release. Without recompiling, StreamBase returns an error message at
runtime.
bin/sbd: error while loading shared libraries ... cannot open shared object file: No such file or directory |
|
Workaround | Recompile your C++ code from your original source against the new headers. | |
SB‑804 | init.d script uses a hard-coded port number. | |
Description |
UNIX only. If you change /opt/streambase/etc/sbd.sbconf to point to a port other
than 10000, then the stop , restart , and status commands in
the /etc/init.d/streambase script do not work
as expected. Those commands assume that sbd is running on port 10000.
|
|
Workaround |
Edit the commands in the /etc/init.d/streambase
script to use the -p option, to force sbd to run on the same port specified in
the modified sbd.sbconf file.
|