SNMP Settings

Option Description
SNMP Daemon By default, the SNMP Daemon is disabled to maintain system security. This option must be enabled if the appliance uses an SNMP Trap Sink. Select Yes to enable this option when you reboot the appliance. See SNMP Trap Sink Settings.
Inbound Polling Community String Type a private or customized community string for your appliance. The default is 20 characters.
Note: It is good practice to change the default value of Inbound Polling Community String because multiple instances of LogLogic EVA must not have the same value.