Server Connection
You can specify the server connection to establish an outbound connection with the SAP system.
Server Connection
In the Server Connection panel of the Server Connection Configuration tab, you can specify the basic and advanced options of the server connection.
If you want to enable the server connection, select the Enabled check box and specify the fields in the Server Connection panel.
The following fields are available in the Server Connection panel when you select the Enabled check box:
Field | Module Property? | Description |
---|---|---|
Connection Type | No | The server connection type.
The default type is Default. |
Program ID | Yes | The program ID that identifies the RFC server program for the SAP system. |
Gateway Service | Yes | The SAP gateway service.
The default service is sapgw00. |
Gateway Host | Yes | The Gateway host name, IP address, or router string.
If no machine exists as a gateway host, this field is specified as the application server. |
The following advanced options are displayed when you click Show/Hide Advanced Options: | ||
Maximum time between two startup attempts in case of failures(secs) | Yes | The maximum time interval in seconds between two successive attempts to establish a connection to the gateway host.
If the connection cannot be established after the maximum time interval, the server connection is suspended. The default value is 60. |
Max Connections | Yes | The number of SAP connections in the server connection.
The default value is 1, and the value range is 1 - 99. |
RFC Trace | Yes | Whether to enable the RFC trace.
The default value is 0. |