Migration Problems

You might encounter problems when you migrate BusinessWork Plug-in Development Kit 6.0 based on TIBCO ActiveMatrix BusinessWorks 6.2.X to version 6.1 based on TIBCO ActiveMatrix BusinessWorks 6.3. You can go over the listed scenarios for troubleshooting.

Scenarios Reason/Workaround
PDK version errors occur. Change a new workspace, or delete the .JETEmitters folders in the old workspace.
The installer that was generated with BusinessWork Plug-in Development Kit 6.0 fails to be installed on TIBCO ActiveMatrix BusinessWorks 6.3. Update the plug-in project dependency based on TIBCO ActiveMatrix BusinessWorks 6.3, and generate a new installer with BusinessWork Plug-in Development Kit 6.1.
When editing processes with the process starter and signal-in activities, code errors occur. Comment out the return isStarted code.
The processes fail to run when the output and fault schema contain any element. Add code manually.
The design-time com.companyname.amf.sca.model.validation bundle is missing. Add the com.companyname.amf.sca.model.validation bundle in the MANIFEST.MF file, or editing the project with ActiveMatrix BusinessWorks Plug-in Development Kit 6.1.0.