Catalog of FTL Server and Service Metrics
This table describes metrics that you can use to assess the operation of the FTL server and services.
FTL Server Metrics
The sampling interval for FTL server metrics is fixed at 2 seconds. You cannot change this interval.
ID | Metric Type | Description |
---|---|---|
5009 | Client Connect Count | Cumulative number of client connections since the FTL server process started. |
5010 | Client Reconnect Count |
Number of clients that reconnected to the FTL server during the sample interval. A spike in this metric could indicate a network connectivity issue between the FTL server and its clients. |
5011 | Send to Inbox Failures | Number of undelivered protocol messages that the FTL server sent to a client.
A spike in this metric usually indicates that several clients abruptly exited. |
Transport Bridge Metrics
Each bridge is itself an application client, and tracks application metrics; see Client Metrics.
The sampling interval for bridge metrics is fixed at 2 seconds. You cannot change this interval.