Data Entry Setup: Main
After you select a Data Entry Setup to modify or choose to create a new Data Entry Setup, the New Data Entry Setup options are displayed in the properties page.
Name
Enter or edit the name of the Data Entry Setup in this box.
Description
Enter or edit a description in this box.
Version
This read-only field displays the version of the Data Entry Setup configuration.
Versions
Click this button to display the Document history dialog box, where you can manage and approve the configuration versions.
Object Summary
Click this button to produce a textual summary of the object and all its properties.
Every form is associated with a specific version of the Data Entry Setup configuration. For example:
- Start Enterprise Manager and create a Data Entry Setup with Characteristics A and B, and approve it.
- Open a browser and visit the Web Data Entry website.
- Enter data in the form for Characteristic A and B.
- Save and complete the form.
- Return to Enterprise Manager and edit the Data Entry Setup. Delete Characteristic B and add a new Characteristic C. Approve the configuration.
- Return to the browser and view the old form entered earlier. You will only see Characteristic A and Characteristic B because that version of the Data Configuration Setup had these fields.
- Create a new form from the Data Entry Setup. You can enter data for Characteristic A and C. The version number of the Data Entry Setup is shown on each form.
Display input.
- By rows
- Select this option button to display the cells in rows, as illustrated below:
- By columns
- Select this option button to arrange the cells for a particular characteristic by column, as illustrated below:
Note:
- Require approval of samples This option only applies to Web Data Entry. Select this check box to require approval of entered data.
-
Example: User One enters data and saves and completes it, which sets a status of Complete. User One can no longer change this data. Only a user with Historical Edit (EDIT) permissions can change the data.
User Two reviews the entered data. If an error is found in the data, User Two can request that the data be revised. If no errors are found, User Two can approve the data. The status of this data is Approved.
User One and User Two cannot be the same person unless this is allowed via System Options - Data Entry options.
An electronic record of the approval is stored in the Audit Log.
- Complete on save
- Select this check box to remove the Save button from the web form. Users of the web form will only see the Save and Complete button. The Save button enables users to enter data without updating the form's status as Complete. The Save button does not require an electronic signature.
- Blind Data Entry
- Enable this option to use double blind data entry verification. Two people enter the same data. The system verifies the entered data matches.
- Manual approval
- While the system verifies that the data entered by two people matches or does not match, the system does not change the data's status to approved. A third user must log on and review the two samples and approve or require revisions.
- Automatic approval
- As soon as the second form is filled out and the
Save and Complete button is clicked, the system verifies if the data matches or does not match. The system automatically approves the sample or requires revisions.
Default analysis. This box identifies which IQC Analysis Configuration is the default analysis that will be run when performing data entry for this Data Entry Setup.
- Sequence
- If the Data Entry Setup is part of a sequence, the sequence is displayed in this field.
Locate. Click this button to locate the corresponding sequence in the System View. The sequence flashes briefly.
- System View Folder
- This box shows the current placement of the current Data Entry Setup in the System View (i.e., to what folder it's attached, if any). Attachments to multiple folders are permitted.
- Attach
- Click this button to display the Select a folder dialog box. The user can then attach the Data Entry Setup to an existing folder.
- Detach
- Click this button to detach the Data Entry Setup from the selected folder in the System View Folder window.
- Locate
- Click this button to show the selected folder to which this Data Entry Setup is attached. The System View node in the tree view will expand (if necessary), and the cursor will briefly flash between highlighting the folder to which the Data Entry Setup is attached and the Data Entry Setup itself.
- Access Permissions
- Click this button to configure the Users/Groups to utilize this Data Entry Setup.
- Launch Data Entry