Administration Messages
The following table describes the administration messages.
Code | Description |
---|---|
SXA1008I | Substation ID:SS-Id VVersion |
Explanation: Displays the Substation ES Identifier and the version number.
Destination: TIBLOG and/or Remote Request Response. |
|
SXA2600I | TIB/SS Console Interface - Awaiting Command Request |
Explanation: This message is displayed on the MVS console when the Write to Operator console interface type is selected in the Substation ES Initialization Parameter. Operations personnel respond to the outstanding request when commands must be issued for the Substation ES to process.
Destination: z/OS MVS console. |
|
SXA2601I | Console Command 'keyword value' |
Explanation: This message echoes an operator-entered Substation ES console command. | |
SXA2602I | Remote Command 'keyword value' |
Explanation: This message echoes an operator command sent from a remote application or the Substation ES General Utility. | |
SXA2603E | Invalid Value: Value supplied for Keyword: Keyword |
Explanation: An invalid
Value has been specified for a valid
Keyword command.
User Response: Supply the correct values and reissue the command. |
|
SXA2604W | No HELP available for Keyword: Keyword |
Explanation: No help is available for Keyword. | |
SXA2605E | Invalid Value: Value supplied for Command: Command |
Explanation: An invalid value (Value) has been supplied for
Command.
User Response: Specify the correct value and reissue the operator command. See the TIBCO Substation ES Installation manual for the console commands. |
|
SXA2606E | Incomplete specification for Command: value |
Explanation: An operator command received by Substation ES is only partially complete. Not all the necessary keywords or values needed to process the command have been supplied.
User Response: See the TIBCO Substation ES Installation manual for the correct command syntax. Correct and resubmit the command. |
|
SXA2607I | Received Remote command text, Scheduled for processing |
Explanation: The remote command text has been received and is scheduled for processing. No additional reply information will be sent to the user because this type of command is scheduled internally and will be processed at some appropriate point. | |
SXA2607W | Command might only be entered via console text |
Explanation: The remote command text can only be submitted on the host system by an authorized operator.
User Response: Contact your Substation ES support representative about authorization. |
|
SXA2608E | Unsupported Value:value supplied for CEMT Command |
Explanation: Substation ES only supports CEMT inquire commands. User Response: Enter CEMT I/INQ/INQUIRE with optional sub-commands to execute the request successfully. |
|
SXA2609I | Operator issued <STOP> command via console |
Explanation: An operator has issued an MVS stop command from a console.
System Action: Substation ES is shut down normally. Destination: TIBLOGPR. |
|
SXA2610E | Invalid Keyword supplied keyword |
Explanation: An invalid console
keyword command has been supplied.
User Response: See the TIBCO Substation ES Operations and Administration manual for the console commands. |
|
SXA2610I | Available Console Command Keywords: |
Explanation: When the HELP console keyword is issued, this header message precedes message SXG2613I, which lists the valid console keywords. | |
SXA2611E | Invalid Keyword: keyword supplied for command: command |
Explanation: An invalid
keyword has been supplied for this console
command.
User Response: See the TIBCO Substation ES Operations and Administration manual for the console commands and keywords. |
|
SXA2613I | Text |
Explanation: This is a general console reply. Console-command replies are formatted with this message ID, which displays the output. | |
SXA2614I | Run-Time value keyword changing from old-value to new-value |
Explanation: A Substation ES console or operator command has been issued, requesting that the operational parameter
keyword be reset or changed. The current value is shown as
old-value and the required value is shown as
new-value.
System Action: Substation ES updates the operational runtime setting to new-value. |
|
SXA2615E | Interface ID required for command:Cmd |
Explanation: An interface ID was required for this command and was not specified on the request submitted.
Destination: TIBLOG and/or Remote Request Response. |
|
SXA2616I | IId:Intf-Id Trigger TRCLVL changing from old-value to new-value |
Explanation: A Substation ES operational command has been issued, requesting that a trigger trace level be changed. The current value is shown as
old-value and the supplied value is shown as
new-value.
System Action: Substation ES updates the operational runtime setting to new-value. |
|
SXA2617E | IId:Intf-Id Interface specified is invalid for request |
Explanation: The Interface specified for the issued operational command is invalid. The Substation ES interface is either not able to process the command specified, or is not eligible to execute the command.
System Action: Specify the correct interface identifier. |
|
SXA2619E | Keyword Value not found |
Explanation: The keyword specified shown is required and could not be found in the command entered.
System Action: Specify the correct operational command and reissue the operator command. See the TIBCO Substation ES Operations and Administration manual for the console commands. |
|
SXA2620I | Operational Request successfully processed |
Explanation: This message indicates that an operational command has completed its scheduled execution. | |
SXA2621I | IId:Intf-Id, Operational Request successfully processed |
Explanation: A command sent to another interface to process has successfully executed. | |
SXA2623E | Missing Keyword: Name in Command: command |
Explanation: A keyword (Name) was expected to be present in an operational command (command), but has not been specified.
User Response: Supply the correct command and keyword with values required and reissue the command. |
|
SXA2631I | Console Commands only written to the Log |
Explanation: An echo of the console commands with the resulting output is only recorded to the log file’s destination.
User Response: None. You can echo console commands and results on the MVS master terminal by specifying the appropriate value for the CONSOLE-MSG System Initialization Parameter keyword. |
|
SXA2632I | This command has no reply: command |
Explanation: The Substation ES operational command
command has been issued but there will be no reply from its operation.
System Action: Substation ES updates the operational runtime settings. |
|
SXA2633I | Nothing (more) to display |
Explanation: There is nothing more to display. | |
SXA2640I | Starting ~ HeartBeats |
Explanation: The Substation ES HeartBeat function has been requested by the user and is now starting to send events to the requested trigger service. The content of the specified operational command(s) is sent to the desired destination.
System Action: Substation ES sends interval heartbeat updates until the connection it sends its delivery on is stopped or a shutdown is performed. If the connection is reestablished the heartbeat will continue again. |
|
SXA2641I | Terminating ~ HeartBeats |
Explanation: The Substation ES HeartBeat function has been stopped.
System Action: Substation ES stops sending the heartbeats at the specified interval until the reason for its termination has been resolved. |
|
SXA2690E | Operations Request has been unsuccessful |
Explanation: An operator command received from a remote application did not execute successfully.
User Response: Review any additional warnings, error messages, and reason codes in the log file to determine the cause for the error condition. If you cannot resolve the error, contact TIBCO Support with the log and trace files. |
|
SXA2645I | HeartBeat sent its information |
Explanation: When the trace level is set at 4 or higher, this message denotes that the trace request has been executed and the information will now be sent to the service for delivery.
User Response: None. |
|
SXA2645E | HeartBeat Stopped. Description |
Explanation: HeartBeat stopped it process after having recorded 10 errors for this activity.
User Response: Review previous messages in the Log file that might indicate the reasons for this message. |
|
SXA2691E | Operational functions disabled due to errors |
Explanation: Failure to allocate the storage for operations results in this facility being disabled.
User Response: Contact TIBCO Support and report the issue supplying the log, trace, and audit files. System Action: Processing continues without administration and operational capabilities. |
|
SXA2693E | Operational request unsuccessful - Notification |
Explanation: Substation ES operations has received a notification from another asynchronous process that it failed at some point during its execution. It also posts this notification to remote processes.
User Response: Review the preceding messages in the Substation ES log to determine the possible cause of the error. If you cannot resolve the error, contact TIBCO Support with the information on the error from the log and trace files. System Action: Substation ES continues to execute normally without disruptions. |
|
SXA2650I | Internal Command value |
Explanation: A Substation ES internal administrative command shown in the value has been requested. If any actions are taken by Substation ES, the messages are shown in the Log file following this command.
User Response: None. |
|
SXA2676I | Requesting Auto Recovery for RID: R-Name |
Explanation: Substation ES issues this message when auto recovery is in progress for a Recipe Service.
User Response: None. System Action: A user has requested an explicit RECOVER for a particular Recipe Service to obtain messages that might possibly be located in the EMS queue and process them. |
|
SXA2685I | Suspending all services for BES:Intf-Id |
Explanation: This is a follow-up message that is issued after the message
SXA2650I. It indicates that all services for this BES will be suspended because of the internal command issued.
User Response: None. |
|
SXA2694E | IPC Unknown Reply event received: num |
Explanation: Substation ES Internal Process Communications has received an invalid event and does not know how to handle this reply.
User Response: Contact TIBCO Support with the information on the error from the log and trace files. System Action: Substation ES continues to execute normally without disruptions. |
|
SXA2695E | Write to Operator failure, RC: RC |
Explanation: An operator command received by the Substation ES administration subtask has failed to execute.
User Response: Review any additional warning or error messages and reason codes in the log file to determine the cause for the error. Contact TIBCO Support with the information on the error from the log and trace files. |