Suppressing CICS Signon or Signoff Messages

In a Substation ES environment using EXCI, a lot of CICS Signon or Signoff messages are produced. To improve system performance, you can suppress all of these messages.

Procedure

  1. Verify that the USERHLQ.ASM(SXCAXMEO) data set is what you want.
    If the data set is correct, all messages for DFHSN1100, DFHSN1200, DFHSN1400, and DFHSN1500 will be suppressed.
  2. If you are using the startup program supplied by TIBCO, add the SXC3XMEN program to the PLT startup program.
    This can be done by uncommenting the following line in the USERHLQ.ASM(DFHPLTXI) member:

    DFHPLT TYPE=ENTRY,PROGRAM=SXC3XMEN

  3. Reassemble the DFHPLTXI member by running the USERHLQ.JCL(SXCASMLK) data set.

    After the CICS region starts, the following confirmation message is displayed:

    SXC3XMEN - EXIT("XMEOUT") SXCAXMEO Installed