List of Available Traps

An SNMP trap is an asynchronous event-generated message that an appliance sends to its client.

The client is a trap receiver which is normally a network monitoring station. The LogLogic appliance supports a set of SNMP traps sent to alert a user.

For SNMP version 1, use the ESTN in the following table.

Categories of Alerts Available as SNMP Traps running version 1
Alert Category Alert Name Enterprise-OID ESTN Description
Cisco PIX Messages Alert Cisco PIX Messages Alert ent.18552.1.3

ent.18552.2.3 (ST)

1 The messages per second rate for a specific PIX message code is outside (later or earlier) specified rates
Network Policy Alert Network Policy Alert ent.18552.1.3

ent.18552.2.3 (ST)

92 A network policy messages was received with an Accept or Deny Policy action
Adaptive Baseline Alert Adaptive Baseline Alert ent.18552.1.3

ent.18552.2.3 (ST)

93 The messages per second rate is outside (later or earlier) the nominal traffic rate
Ratio Based Alert Ratio Based Alert ent.18552.1.3

ent.18552.2.3 (ST)

94 The specified message count is outside a specified percentage of total messages
VPN Statistics Alert VPN Statistics Alert ent.18552.1.3

ent.18552.2.3 (ST)

95 Recorded statistics on VPN or RADIUS messages match relative or absolute criteria
VPN Connections Alert VPN Connections Alert ent.18552.1.3

ent.18552.2.3 (ST)

96 A VPN Disconnects or Deny event occurred
VPN Messages Alert VPN Messages Alert ent.18552.1.3

ent.18552.2.3 (ST)

97 A VPN Message Alert triggered on combinations of specific VPN message area, severity, and code
Message Volume Alert Message Volume Alert ent.18552.1.3

ent.18552.2.3 (ST)

98 The messages per second rate is outside (later or earlier) specified limits. If the user sets the “Zero Message Alert” checkbox, an alert is triggered only if zero messages are received within the timespan set.
Pre-defined Search Filter Pre-defined Search Filter Alert ent.18552.1.3

ent.18552.2.3 (ST)

99 A text search filter matched message fields
System Alert Dropped- message ent.18552.1.3

ent.18552.2.3 (ST)

189 Dropped messages exceeded the user-specified limit
  Failover ent.18552.1.3

ent.18552.2.3 (ST)

191 A failover occurred
  Disk Usage ent.18552.1.3

ent.18552.2.3 (ST)

192 Disk usage exceeded the specified threshold
  Network Connection Speed ent.18552.1.3

ent.18552.2.3 (ST)

193 Network connection throughput fell under the specified threshold
  Network Interface ent.18552.1.3

ent.18552.2.3 (ST)

194 The configured network interface failed
  Data Migration ent.18552.1.3

ent.18552.2.3 (ST)

195 A data migration completed
  CPU temperature ent.18552.1.3

ent.18552.2.3 (ST)

197 The CPU temperature exceeded the specified limit
  Synchronization Failure ent.18552.1.3

ent.18552.2.3 (ST)

198 Data synchronization failed after a failover
  Secure Tunnel connection status ent.18552.1.3

ent.18552.2.3 (ST)

199 The configured TCP forward connection failed

If you are using SNMP version 2, the TrapOID differs for each trap. The following table lists the TrapOID for each alert category.

Note: The TIBCO LogLogic appliance uses SNMP v1 by default. In order to use v2c the admin needs to edit the following file:
Logapp root:~$ cat /loglogic/conf/snmpd_alerts_trap_version
version: 1 type: snmptrap
Logapp root:~$

Update the version from 1 to 2 in the file. If this file does not exist, create the file with:
version: 1 type: snmptrap

The file can then be edited to version 2 if required.

Categories of Alerts Available as SNMP Traps running version 2
Alert Category Alert Name TrapOID Description
Cisco PIX Messages Alert Cisco PIX Messages Alert ent.18552.1.3.3

ent.18552.2.3.3 (ST)

The messages per second rate for a specific PIX message code is outside (later or earlier) specified rates
Network Policy Alert Network Policy Alert ent.18552.1.3.92

ent.18552.2.3.92 (ST)

A network policy messages was received with an Accept or Deny Policy action
Adaptive Baseline Alert Adaptive Baseline Alert ent.18552.1.3.93

ent.18552.2.3.93 (ST)

The messages per second rate is outside (later or earlier) the nominal traffic rate
Ratio Based Alert Ratio Based Alert ent.18552.1.3.94

ent.18552.2.3.94 (ST)

The specified message count is outside a specified percentage of total messages
VPN Statistics Alert VPN Statistics Alert ent.18552.1.3.95

ent.18552.2.3.95 (ST)

Recorded statistics on VPN or RADIUS messages match relative or absolute criteria
VPN Connections Alert VPN Connections Alert ent.18552.1.3.96

ent.18552.2.3.96 (ST)

A VPN Disconnects or Deny event occurred
VPN Messages Alert VPN Messages Alert ent.18552.1.3.97

ent.18552.2.3.97 (ST)

A VPN Message Alert triggered on combinations of specific VPN message area, severity, and code
Message Volume Alert Message Volume Alert ent.18552.1.3.98

ent.18552.2.3.98 (ST)

The messages per second rate is outside (later or earlier) specified limits. If the user sets the “Zero Message Alert” checkbox, an alert is triggered only if zero messages are received within the timespan set.
Pre-defined Search Filter Pre-defined Search Filter Alert ent.18552.1.3.99

ent.18552.2.3.99 (ST)

A text search filter matched message fields
System Alert Dropped-message ent.18552.1.3.189

ent.18552.2.3.189 (ST)

Dropped messages exceeded the user-specified limit
  Failover ent.18552.1.3.191

ent.18552.2.3.191 (ST)

A failover occurred
  Disk Usage ent.18552.1.3.192

ent.18552.2.3.192 (ST)

Disk usage exceeded the specified threshold
  Network Connection Speed ent.18552.1.3.193

ent.18552.2.3.193 (ST)

Network connection throughput fell under the specified threshold
  Network Interface ent.18552.1.3.194

ent.18552.2.3.194 (ST)

The configured network interface failed
  Data Migration ent.18552.1.3.195

ent.18552.2.3.195 (ST)

A data migration completed
  CPU temperature ent.18552.1.3.197

ent.18552.2.3.197 (ST)

The CPU temperature exceeded the specified limit
  Synchronization Failure ent.18552.1.3.198

ent.18552.2.3.198 (ST)

Data synchronization failed after a failover
  Secure Tunnel connection status ent.18552.1.3.199

ent.18552.2.3.199 (ST)

The configured TCP forward connection failed